Programmable Frequency Rate Meter frequency / Rpm / Speed / Fluid Features Trueprocessfrequency/rpm/speedratemonitor Wide input sensitivity range from 10 mV to 100V Rangeable of display scale for 4 digital rate setting High accuracy of 0.02% 12 or 24V exciting voltage provided 4 digits of mximum 9999 counts Display with super rate LED Discription Model MRF is designed to accept frequency count input type & offers a very flexible & switchable ability in frequency rate conditioning with digital setting & getting required scale. Itfeatures: 1.Designed of a wide input range span from 0 to 100Hz to 0 to 20KHz & maximum scale 0 to 9999 counts 2.Switchable input range multiplier of 1/10/100 time selection & rate multiplier of 4 digits 0.0001 to 0.9999 3.Selectable decimal point in matching proper engineering unit. 4.Input discriminator for sensitivity adjustment, range from 10 mV to 5V 5.Exciting voltage provided of switchable range ither 12 or 24V for sensor simulating source for field application. Specification Accuracy(23±3°C) Stability Digits & Display Configuration Exciting voltage response time Input signal Input discriminator Input over Com. mode voltage Operating condition Auxiliary power 0.05%fs + 1 count Temperature coefficient < 40 ppm per degree C, long term draft<0.002% per year 0.56 super rate LED, maximum 9999 counts Programmable rate function of 4 digital resolution 0.0001 to 0.9999 Selectable 12 & 24 voltages with load capability of 25 mA maximum Sample rate 1 of per sec typically Sensitivity : 10mV to 100V Waveform : periodical of unipolar or bipolar of voltage type or open collector. 10mV to 5V adjustable Maximum 250 Vrms for voltage input 2 KVrms / 1 minute 50 / 60 Hz. Temperature range -10 to 55° C, 0-99% RH non-condensed, storage-25 to 70°C AC ±15% < 3.5 VA, DC ± 20% < 5 watts d1 SD digital rate setter 0-9 0-9 0-9 0-9 x0.1 x0.01 x0.001 x0.0001 d2 d3 SF 12345678 discriminator 1 10 100 d1 d2 d3 excitingvoltage,on=12V;off=24V range constant=K Order from Model MRF Frame ( in mm) 96x48 U Auxiliary power AC 110 & 220 V S DC option 12 V 1 DC option 24 V 2 DC option 48 V 3 DC option 125 V 4 Input range & calibration Standard calibration 0-99.99%, display for 1khz input S Customer specified Y Function of switches SD-Digital rate seter 4 digits rate multiplier, setting range from 0.0001 to 0.9999 SF-Function switch 1.Decimal point selection of poles P6,P7,P8. Status:on = enable 2.Input range gain selection of range constant K of 1,10,100, controlled by P1,P2,P3. 3.Exciting voltage output for sensor source of 12V & 24V controlled by P4, status : on = 12V, off = 24V Switching formula N = rate setting, R = input frequency, k = range constant N = R/ (FxK)..........# ( F x K ) should ( > or = ) R, @ R < ( F x K ) > 0.1R, K with proper selection Example : 0-250Hz input, required display 0-800.0 800.0 = 8000 counts under @R< ( F x K ) > 0.1R, K = 100, N = 8000 / ( 250 x 100 ) = 0.32 Terminal connection + - + + - 1 2 3 4 5 Pulse Input Exciting Voltage Open Collector Input + (DC option) 6 7 8 AC 110V AC 220V Auxiliary Power