Download Complete Technical Specifications

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Switched-mode power supply wikipedia , lookup

Ground (electricity) wikipedia , lookup

Alternating current wikipedia , lookup

Printed circuit board wikipedia , lookup

Opto-isolator wikipedia , lookup

Transformer wikipedia , lookup

Mains electricity wikipedia , lookup

Fault tolerance wikipedia , lookup

Single-wire earth return wikipedia , lookup

Surface-mount technology wikipedia , lookup

Transformer types wikipedia , lookup

Flexible electronics wikipedia , lookup

Regenerative circuit wikipedia , lookup

Integrated circuit wikipedia , lookup

Earthing system wikipedia , lookup

Electrical substation wikipedia , lookup

Residual-current device wikipedia , lookup

RLC circuit wikipedia , lookup

National Electrical Code wikipedia , lookup

Circuit breaker wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Transcript
Factory Sealed, Single & Two-Pole
Circuit Breakers
Applications:
Standard Materials:
D2PB panelboards are designed specifically
for use:
• In Class I, Division 2, Groups C, D
hazardous areas where flammable vapors
or gases may be present due to accident or
abnormal locations
• In damp, wet or corrosive locations
• Indoors or outdoors in Division 2 areas of
petroleum refineries, chemical and
petrochemical plants, and other process
industry facilities
For general application, circuit breaker and
wiring system information, see
pages 626–629.
• Bodies, covers and hinged doors –
copper-free aluminum
• Breaker operating handles – type 6 / 6
nylon
• Interior parts – sheet steel
Features:
1A
Standard Finishes:
• Copper-free aluminum – natural
• Type 6 / 6 nylon – natural (black)
• Sheet steel – electrogalvanized with
chromate finish
Options:
Description:
Suffix:
• Panelboard provided with
operating handle lockouts for
lockout in ON or OFF positions.
Stainless steel lockout frame
integral to panel faceplate.
D2PB Size 1..................................... L12
D2PB Size 2..................................... L24
• Branch conduit entries furnished
with Eaton's Crouse-Hinds type
PLG plugs.......................................... S822
• Square head plugs in all openings.... S872
• Branch circuit conduit openings
located at bottom instead of at top.. INV
• Drilled and tapped conduit
openings other than standard –
available on special order – specify..
I
• Breather and drain............................ DV
• Circuit breaker operating handle
lockout - order D2PB02
• Assortment of single-pole and
two-pole circuit breakers and trip
ratings – see listings.
Wiring system other than those listed –
Specify
See page 628
Dimensions
1A
• Enclosures are of external flange design,
which makes the interior completely
accessible when the cover is removed
• Provided with concealed mounting, which is
made possible by having four clearance
holes for lag screws or mounting bolts in
the back of the enclosure, one in each
corner
• The interior sub-assembly, consisting of a
mounting plate, main terminal blocks, and
circuit breakers, is removable as a complete
unit
• Ample gutter space is provided for ease of
field wiring
• Circuit breakers are contained in compact,
individual factory sealed enclosures suitable
for Class I, Division 2, Groups C, D
hazardous areas. The individual enclosures
are easily removed and replaced, therefore
changing or adding individual circuit
breakers will not present a problem
• The main cover, which is gasketed to
exclude dirt and moisture, is attached to the
body with hex head bolts and is removed
only when installing the panelboard or
making wiring changes. In the center of the
main cover is a gasketed hinged door,
which provides access only to the circuit
breaker operating handles, and is held
closed by two quick release catches. The
door can be locked by as many as 3
padlocks to prevent unauthorized operation
• Tapped conduit openings are provided for
main conduit and branch circuits, as shown
in the dimensional information. Standard
openings can be reduced or plugged to
meet most installation requirements
• Circuit breakers are arranged in two vertical
rows and have the circuit numbers marked
on the handles. The left row is numbered 1,
3, 5, 7, etc. and the right row 2, 4, 6, 8, etc.
Identifying information may be typed on the
circuit directory card attached to the inside
of the hinged door
Wet Locations
Cl. I, Div. 2, Groups C, D
NEMA 3, 7CD (Div. 2), 12
Dust-tight
Raintight
D2PB Division 2 Circuit Breaker
Panelboards
Size Ranges:
Panel Size
Max. No. of Breakers
Single-Pole
Two-Pole
1
2
12
24
6
12
Electrical Rating Ranges:
•
•
•
•
Circuit breakers
Single-pole – 120/240VAC max.
Two-pole – 120/240VAC max.
Trip ratings – 15, 20 and 30 amp
In Inches:
Certifications and
Compliances:
• NEC:
Class I, Division 2, Groups C, D
• NEMA: 3, 7CD (Division 2), 12
• UL Standard: 67, 877
Dimensions are approximate, not for construction purposes.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
663
1A
Cl. I, Div. 2, Groups C, D
NEMA 3, 7CD (Div. 2), 12
Dust-tight
Raintight
D2PB Division 2 Circuit Breaker
Panelboards
Factory Sealed, Single & Two-Pole
Circuit Breakers
Wet Locations
D2CB12-20
Replacement Circuit
Breaker Assemblies
D2PB with Main Breaker Option
Where D2PB (and N2PB) panelboards have
been ordered with less than the maximum
number of circuit breakers, breakers can
easily be added in the field. Circuit breaker
assemblies for field addition or
replacement are listed below; they consist
of the breaker itself in its factory sealed
Class I, Division 2, Groups C, D enclosure,
and necessary mounting hardware. These
assemblies are not suitable for use as
individually mounted units.
Ordering Information:
1A
Panelboards are available with single-pole and two-pole, 15, 20, or 30 ampere circuit
breakers. To order a panelboard with all breakers of the same rating, add the desired rating
as a suffix to the Cat. No. For example, the 12 circuit D2PB1512 panelboard with all the
circuit breakers rated at 20 amperes would be ordered as D2PB1512-20.
Panelboards shown below can also be furnished with an assortment of single-pole and twopole breakers and breaker ampere ratings. To order, the quantities of breakers and ampere
ratings are added as a suffix to the Cat. No. The total number of poles will determine the
panel size (24 poles maximum), and the wiring systems must be compatible when
combining single- and two-pole circuit breakers. For example, a typical D2PB panelboard
with a combination of 3 single-pole 15 ampere, 3 single-pole 20 ampere, 2 single-pole 30
ampere, 4 two-pole 20 ampere, and 4 two-pole 30 ampere circuit breakers would be
ordered as D2PB2508-315-320-230-808-420-430. The total number of poles is 24 and
wiring systems 5 and 8 are compatible 4 wire, 3 phase.
The D2PB with a main breaker is available up to 100 amps. To order D2PB with main
breaker, add the appropriate suffix. Example: D2PB1512-15 with three-pole, 100 amp main
circuit breaker would be ordered as D2PB1512-15-3M100. If two-pole main is required,
change the number 3 to 2. If a lower trip rating than 100 is required, the suffix will change
accordingly.
Max. No. of
Breakers
SinglePole
TwoPole
Panel
Size
Main
Lug
Size‡
6
8
10
12
4
5
6
1
1/0
12
6
14
7
16
8
2
4/0
18
9
20
10
22
11
24
12
➀Add ampere rating. See ordering information.
Single-Pole Circuit Breakers
Wiring System 4*
Wiring System 5*
Mains: 3-Wire
Mains: 4-Wire, 3-Phase
Branches: 2-Wire
Branches: 2-Wire
Solid Neutral
Solid Neutral
Cat. #
Cat. #
Circuit Breaker Assemblies
Ampere
Rating
Single-Pole
Cat. #
Two-Pole
Cat. #
15
20
30
D2CB11 15
D2CB11 20
D2CB11 30
D2CB12 15
D2CB12 20
D2CB12 30
Two-Pole Circuit Breakers
Wiring System 3*
Wiring System 8*
Mains: 3-Wire
Mains: 4-Wire, 3-Phase
Branches: 3-Wire
Branches: 3-Wire, 1-Phase
Solid Neutral
Solid Neutral
Cat. #
Cat. #
D2PB1406
D2PB1408
D2PB1410
D2PB1412
➀
➀
➀
➀
D2PB1506
D2PB1508
D2PB1510
D2PB1512
➀
➀
➀
➀
D2PB1304 ➀
D2PB1305 ➀
D2PB1306 ➀
D2PB2412
D2PB2414
D2PB2416
D2PB2418
D2PB2420
D2PB2422
D2PB2424
➀
➀
➀
➀
➀
➀
➀
D2PB2512
D2PB2514
D2PB2516
D2PB2518
D2PB2520
D2PB2522
D2PB2524
➀
➀
➀
➀
➀
➀
➀
D2PB2306
D2PB2307
D2PB2308
D2PB2309
D2PB2310
D2PB2311
D2PB2312
D2PB1804 ➀
D2PB1805 ➀
D2PB1806 ➀
➀
➀
➀
➀
➀
➀
➀
D2PB2806
D2PB2807
D2PB2808
D2PB2809
D2PB2810
D2PB2811
D2PB2812
p
➀
➀
➀
➀
➀
➀
➀
‡1/0 lug, rated 125 amps. takes wire sizes #6 to 1/0; 4/0 lug, rated 225 amps. takes wires sizes 1/ 0 to 4/ 0.
*For description of these standard wiring systems, see page 628.
Dimensions
Overall and Mounting
Dimensions (In.)
a
b
c
Panel Size Without Main C.B.
1
203/4
8
16
2
113/4
231/2
281/4
Conduit Openings
Spacing (In.)
f
g
h
j
Size (In.)
k
m
n✪
73/4
113/8
3
3
11/4
11/4
11/4
11/4
11/4
11/4
Panel Size With Main C.B.
1
8
16
73/4
203/4
2
113/4
231/2
113/8
281/4
✪Conduit opening "n" not supplied on panel size 1.
664
www.crouse-hinds.com
US: 1-866-764-5454
31/2
31/16
2
115/16
115/16
5
5
115/16
115/16
115/16
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
21/2
21/2
Quantity
Main Branches
2
2
8
12
2
2
8
12
Cl. I, Div. 2, Groups B†, C, D
NEMA 3, 4‡, 7B†CD (Div. 2), 12
Wet Locations
Watertight‡
D2PB, D2L, D2D Circuit Breaker
Panelboard Assemblies
with Transformer
Applications:
Standard Materials:
D2PB, D2L, D2D circuit breaker
panelboard assemblies with transformers
are for use:
• In Class I, Division 2, Group C, D
hazardous areas where, due to accident
or abnormal operations, flammable
vapors or gases may be present, and
which are subject to weather, dampness
and corrosion
• Indoors or outdoors in Division 2 areas
such as petroleum refineries, chemical
and petrochemical plants, and other
process industry facilities
• Where high voltage supply must be
stepped down to the lower voltage
necessary to serve lighting, heating,
appliance, heat tracing, motor and
similar circuits
For general information on panelboard
applications, circuit breakers and wiring
systems, see pages 626–629.
• Frames – structural aluminum
• Mounting hardware – stainless steel
• Transformer enclosure – sheet steel,
welded
• For panelboard materials, see individual
listing pages
• The factory assembled panelboard and
transformer are on one compact frame,
suitable for either wall or pole mounting.
Wiring between the transformer
secondary and main lugs of the
panelboard is accomplished at the
factory.
• Easy to install and wire. The main feed is
connected to the transformer primary
and the branch circuits are wired to the
panelboard terminal blocks.
• The assembly can be installed in the
load area to reduce the length of runs of
low voltage branch circuits.
• Panelboards used are standard D2PB,
D2L, or D2D units with circuit breakers
listed in this section.
• Transformers are compound filled or
epoxy filled to completely seal out
moisture and dirt.
Standard Finishes:
•
•
•
•
Aluminum – natural
Stainless steel – natural
Sheet steel – primed and painted
For panelboard finishes, see individual
listing pages
Options:
• Material – structural steel frames
• Finish – primed and painted or hot dip
galvanized
• For options available on the panelboards
themselves, see individual listings pages
1A
Features:
1A
Size Ranges:
Transformers
Single or three-phase – 5kVA to 30kVA
Panelboards
Max. No. of Breakers
SingleTwopole
pole
D2PB
24
12
D2L
42
20
D2D
30
14
Threepole
14
10
Electrical Rating Ranges:
• Transformers – 480 volt primary
• Transformers – 120 / 240 volt secondary
• Panelboards – see individual listings
Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Group B†, C, D
• NEMA/EEMAC: 3, 4‡, 7B†CD (Division 2),
12
• UL Standard: 67, 1604
• CSA Standard: C22.2 No. 213
† D2L, D2D with GB suffix and breather and drain holes plugged.
‡ NEMA 4 hosetight with breather and drain openings plugged.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
665
1A
D2PB, D2L, D2D Circuit Breaker
Panelboard Assemblies
with Transformer
Cl. I, Div. 2, Groups B†, C, D
NEMA 3, 4‡, 7B†CD (Div. 2), 12
Wet Locations
Watertight‡
Typical Assembly*
Ordering Check List
24 Circuit D2PB panelboard with single-phase
transformer
1. Select the D2PB, D2L, D2D panelboard required, together with
any applicable options or special features. See individual listing
pages.
Cat. No.
2. Provide the following information, necessary for selection of the
correct transformer:
Primary voltage
Secondary voltage
kVA rating
Taps – number and percent
Frequency (60 cycle unless otherwise specified)
Single or three-phase
1A
Other requirements
*Dimensions are approximate, not for construction purposes.
† D2L, D2D with GB suffix and breather and drain holes plugged.
‡ NEMA 4 hosetight with breather and drain openings plugged.
666
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business