* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Download T2100 Datasheet
Spark-gap transmitter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power factor wikipedia , lookup
Electric power system wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrification wikipedia , lookup
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Power inverter wikipedia , lookup
Electrical substation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Earthing system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power MOSFET wikipedia , lookup
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power electronics wikipedia , lookup
Distribution management system wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Protective relay wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Protection Relays & Controls Generator & Single-Function Protection–Excitation Loss T2100 Series Excitation Loss Relay Description The T2100 Excitation Loss Relay protects against loss of excitation in a synchronous generator. T2100 detects the high-inductive current running into a generator in case of low excitation. The faulty generator breaker is tripped, thus protecting the generator, and avoiding undervoltage on the busbar with a possible blackout of the system. The T2100 calculates I x sin φ, representing the reactive power. If the reactive power becomes negative and exceeds the preset level (0.5-1.5 x IN), the pickup LED will indicate and the delay timer will be started. After the preset time (2-20 sec.) has expired, the output relay and LED will be activated, provided that the negative reactive power level was exceeded for the entire delay time. Simplified Circuit Diagram G L - L SUPPLY Features & Benefits Features 1 2 3 13 RESET 14 Accepts high supply voltage variation T2100 7 8 9 10 (Excitation Loss Relay) 5 6 L1 C/B TRIP L2 L3 LOAD G L - N SUPPLY T2100 7 8 9 10 6 L1 C/B TRIP L2 L3 LOAD Ordering Information Ordering Number 1-3 T2100.0010 230 V 5A L-N T2100.0020 480 V 415 V 5 A L-L T2100.0030 450 V 400 V 5 A L-L T2100.0040 110 V 100 V 1 A L-L T2100.0050 110 V 100 V 5 A L-L T2100.0060 110 V 100 V 5 A L-L Current 0.2-1.2 x IN T2100.0070 480 V 415 V 5 A L-L Normally energized output, current 0.05 -0.15 x IN T2100.0080 110 V 100 V 5 A L-L 24 V DC aux. voltage supply, current 0.2 1.2 x IN 2-3 IN Galvanic isolated inputs Provides quick and concise status information Simplifies design and installation. No need for PTs. Safe operation. Maintains protection regardless of system voltage failure Protects the unit against high AC voltage and currents from the installation including spikes Easy installation Specifications (Excitation Loss Relay) 5 Terminals Available with separate 24 Vdc supply DIN-rail or screw-mount & adjustment by potentiometers 1 2 3 13 RESET 14 Visual indication of power, pick-up, and output trip Direct line-line or lineneutral voltage supply (up to 690 Vac) BENEFITS Ensures correct operation in spite of voltage supply fluctuations (fulfills marine class requirement) supply function Trip Level 0.5-1.5 x IN Delay 2-20 sec. Max. Voltage 660 V Voltage Range 50-110% Voltage 5 VA at UN Consumption Current 0.3 VA at IN Continuous Current 2 x IN Frequency Range 45-400 Hz Output Relay Normally de-energized, latching, resetable Contact Rating AC: 400 V, 5 A, 1250 VA DC: 150 V, 5 A, 120 W Overall Accuracy ±5% Repeatability ±1% Operating Temperature –20°C to + 70°C Dielectric Test 2500 V, 50 Hz EMC CE according to EN50081-1, EN50082-1, EN50081-2, EN50082-2 Approvals Certified by major marine classification societies Burn-in 50 hours before final test Enclosure Material Polycarbonate. Flame retardant Weight 0.5 kg DimensionsH 70 mm (2.76”); W 100 mm (3.94”); D 115 mm (4.52”) Installation 35 mm DIN rail or 4 mm (3/16”) screws www.BDTIC.com/littelfuse Other supply voltages and combinations are available on request. © 2013 Littelfuse Protection Relays & Controls Littelfuse.com/t2100 Rev: 4-A-050213