CAT. NO. D -F-13203 FIRE ALARM PANEL FAP232N-5L FEATURES ● Conventional type ● Alarm verification type (Alarm verification time : 60 seconds) ● Various test functions : fire indication test, line continuity test, auxiliary power supply test, and alarm verification time test. ● Durable LED indications ● Back-up power supply (Ni-Cd battery, 24VDC) ● Easy maintenance ● Automatic self-checking system DESCRIPTION On receiving a fire signal from a fire detector or a manual alarm box, the FAP232N-5L conventional fire alarm panel gives visual alarms indicating the alarm point, as well as an audible alarm, to alert the alarm panel operator. It also produces alarms to alert the occupants of the building premises. The FAP232N-5L conventional fire alarm panel has indication of the alarm points by individual zone lamps. SPECIFICATIONS Model no. FAP232N- 5L TYPE Wall mounting type POWER SUPPLY 220VAC 50/ 60Hz AUX. POWER SUPPLY CIRCUIT VOLTAGE ALARM VERIFICATION TIME POWER CONSUMPTION MAX. NUMBER OF APPARATUS TO BE CONNECTED AMBIENT TEMPERATURE AND HUMIDITY LOOP RESISTANCE OF ALARM INPUT CIRCUIT END-OF -LINE RESISTOR MATERIALS (ENCLOSURE) 24VDC Ni-Cd battery 0.225AH(Charging current : Approx. 4.7mA) 5,24,48VDC, 24VAC Thermal detector : 10sec., Smoke detector : 60sec. ● Max. approx. : 14VA for monitoring ● Max. approx. : 31VA for alarming ● Spot type smoke detectors : 30/zone(Max. 50/panel) ● Local alarm bells : 10(24VDC, 10mA/bell) ● Location lamps : 5(30V, 2W/lamp) 14(24V, 24mA/lamp) 0 to 40℃ , 20 to 85%(RH) Less than 50 Ω / Loop 10kΩ 1/2W ABS resin with non-flammability to 94UL-V2 COLOR Beige/yellow : Nearly to Munsell 2.5Y 9/1, semi-glare WEIGHT Approx. 2.7kg ●HEAD OFFICE:7-3, Kudan-Minami 4-chome, Chiyoda-ku, Tokyo 102-8277, Japan ●PHONE: (81)3-3265-0231 ●FAX: (81)3-3265-5348 FIRE ALARM PANEL FAP232N-5L CAT. NO. D -F-13203 TYPICAL WIRING DIAGRAM End-of-line resistor Manual fire alarm box Detector line : 30 Smoke detectors per line(Max.50/panel) No limit for contact type heat detectors. Alarm signal lines (L) Common line (C) Fire alarm bell Location lamp Fire alarm bell NUMBER of WIRES(BASIC) 5−Alarm signal lines (L) 1−Common line (C) for all zones 1−Response line (A) 2−Fire alarm bell lines (B) 2−Location lamp lines (PL) External line resistance : Less than 50Ω/Loop Terminals : for use withφ 0.5∼2.0mm wire n+4 wires 220VAC 50/60Hz Annunciator (*) *Note : An optional unit is required for the fire alarm panel when the annunciator is connected. Fire alarm panel DIMENSION (WALL MOUNTING TYPE) 6 5 7 1 2 380 3 250 4 30 80 UNIT:mm ①CABINET PANEL ②CABINET BODY ③LOCK ④SWITCH COVER ⑤EQUIPMENT NAME PLATE ⑥ZONE LAMP ⑦ZONE NAMEPLATE ● These instructions do not purport to cover all the details or variations in the equipment described, nor provide for every possible contingency to be met in connection with installation, operation and maintenance. ● Specifications are subject to change without notice. Contact Nohmi before relying on above specifications. ● Actual performance is based on proper application of the product by a qualified professional. ● Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser's purposes, the matter should be referred to Nohmi or a distributer in your region. OFFICE : 7-3, Kudan Minami 4-chome, Chiyoda-ku, Tokyo 102-8277, Japan ●PHONE : (81) 3-3265-0231 ●F A X : (81) 3-3265-5348 ●U R L : http://www.nohmi.co.jp/english/ ●HEAD 100401D -F-13203YO2