* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Diapositive 1 - Schneider Electric
Survey
Document related concepts
Transcript
PowerLogic EGX300 Integrated gateway-server PowerLogic EGX300 Integrated gateway-server ● Use your existing Ethernet network to access basic electrical system data ● View data with only a web browser, no power monitoring software needed ● Log data onboard the EGX300 for historical system analysis View device data through a simple browser – no software needed EGX300 web page Trend plots Data log files EGX100 EGX300 Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100) Schneider Electric – March 2009 ION PM800 Microlog Sepam 2 Benefits ● Get a complete view of your electrical system including: ● Meters ● Circuit breaker control units ● Protective relays ● Motor controllers ● Drives ● Operating on an existing Ethernet network, the PowerLogic EGX300: ● Helps lower installation costs ● Accesses multiple Ethernet devices and gateways across the network and logs data from connected devices ● Offers high performance and reliable communication ● Simple Ethernet connection with minimal configuration required ● Provides easy system expansion: Dynamic device additions ● Is compliant with industry standards (UL, CSA, FCC, CE) Schneider Electric – March 2009 3 Benefits ● View real time data using only a web browser ● Analyse basic data from your electrical distribution system for cost allocation and trending reports ● Use the embedded web page creation tool to customise your system data views and add additional devices ● Detect devices throughout the system with device Autodiscovery tool Schneider Electric – March 2009 4 Benefits ● ● ● ● ● Functions as a gateway from Ethernet to serial line devices Connects up to 64 devices per gateway Offers field upgradeable firmware Features Modbus TCP/IP address filtering Features 256 Mb for onboard data logging Workstation s PLC Modbus TCP Web browser Modbus TCP Master Modbus TCP/IP Filtering Feature controls access to critical devices Schneider Electric – March 2009 Example: - PLC allowed access - One workstation not allowed access - Level of access configurable for read-only or full access Modbus serial line critical control 5 EGX300 user interface – home page Easy navigation toolbar Customisable home page. Set up to view Monitoring, Control, Diagnostics, Maintenance, etc. Schneider Electric – March 2009 6 EGX300 user interface – per device View real time data per individual device Schneider Electric – March 2009 7 EGX300 user interface – per device View logged data per device Schneider Electric – March 2009 8 EGX300 user interface – summary views Overview of all connected devices Overview of load current of all devices Overview of demand current all devices Schneider Electric – March 2009 9 EGX300 user interface – summary views Overview of power for all devices Overview of energy for all devices Schneider Electric – March 2009 10 Exterior features Control power: RJ45 Ethernet port (IEEE802.3af) 24 Vdc or Power-overEthernet (PoE) LED indicator for power & status Recessed reset button LED indicators for Ethernet and serial communications Schneider Electric – March 2009 11 Exterior features RS485 serial port Bias, Termination, and 2-wire / 4-wire jumper switches Schneider Electric – March 2009 RS232 serial port (RJ45 connector) 12 Technical highlights ● Ethernet ● 10/100BaseTX ● Concurrent ModbusTCP/IP connections: 64 ● Serial ● All lines optically isolated for high reliability in industrial networks ● Protocols: ModbusRTU, ModbusASCII, Powerlogic (SY/MAX), Jbus ● Environmental ● Operating temperature: -25o to 70oC ● Enclosure: Din-rail mount ● IP rating: IP30 Schneider Electric – March 2009 13 EGX300 user interface – setup Easily set up the media type and Ethernet IP parameters. Easily set up the media type and serial parameters. Schneider Electric – March 2009 14 EGX300 user interface – device discovery The Autodiscovery feature detects devices automatically and allows you to customise device names, saving you time. Schneider Electric – March 2009 15 EGX300 user interface – setup Customise device names Schneider Electric – March 2009 16 EGX300 user interface – setup Device Logging Schneider Electric – March 2009 Set logging intervals and choose from a customisable list of logging topics. Log up to 10 topics. 17 EGX300 user interface – setup Password protection and controlled network access ensures data and system security. Schneider Electric – March 2009 18 EGX300 user interface – setup Customise network access to individual web pages. Schneider Electric – March 2009 19 EGX300 user interface – setup Support standard MIB II for SNMP only Schneider Electric – March 2009 20 EGX300 user interface – data logging Choose to receive the most up-to-date data or all data sent via email or ftp Schneider Electric – March 2009 21 Accessory: Configuration kit (TCSEAK0100) ● Allows configuration via RS232 serial or Ethernet port ● Kit contents: ● RJ45 to DB9F adapter ● CAT5 Crossover cable, 3-meters (10-feet), orange ● Instruction sheet Schneider Electric – March 2009 22 Accessory: PoE Injector (TCSEAV0100) ● Typically, the largest cost associated with installing a gateway into an existing installation is the cost to provide control power ● The Power Over Ethernet (PoE) standard (IEEE 802.3af) defines how control power can be provided to an end device through a standard CAT5 Ethernet cable ● PoE eliminates the need for Control Power Transformers, disconnects, and AC-DC power supplies while greatly reducing installation time ● Kit contents: ● PoE midspan injector ● Universal power cord, 2 meters ● Plug adapters for Australia, Europe, UK, USA ● CAT 5 Ethernet patch cable, 2 meters ● Instructions Schneider Electric – March 2009 23 For more information … ● Please visit www.PowerLogic.com Schneider Electric – March 2009 24