Download from the Diagnostics menu
Survey
Document related concepts
Transcript
Connexium Managed Switches Diagnostics June 2010 Connexium Managed Switch Diagnostic Capabilities ● The Connexium Managed Switches include a wide selection of diagnostic tools that simplify the maintenance and setup of an Ethernet network ● These diagnostic capabilities range from indicator lights that provide local status on switch operation to event logging that includes time stamping of up to 2000 events. ● With the web based switch configurator, you can select the diagnostic capabilities that best suit your application and facility requirements. Schneider Electric - Division - Name – Date 2 Connexium Managed Switch Diagnostic Capabilities - Summary ● Event Log Files - HTML file that logs up to 2000 events, with a time stamp that contains system information and port statistics ● LED Indicators - For power, link/activity, fault detection and redundancy manager. ● Alarm Relay - External relay contact that alarms on configured switch status, such as power source error detection, temperature, ring redundancy, connection error detection etc. ● SNMP Traps - You can configure switch to send SNMP traps for configured switch parameters to a device; you need to use a network management software that supports SNMP traps. ● Port Mirroring - Copies data passing through one port (source) to another port to allow troubleshooting with a network protocol analysis tool. ● IEEE 802.1ab Topology Discovery - Enables the automatic detection of devices and network topology mapping. Schneider Electric - Division - Name – Date 3 Diagnostics Event Log Files ● Event Log capability does not require configuration ● Accessed through switch web page ● Switch logs events and system information that includes a time stamp ● Up to 2000 events can be logged ● Log information is not lost if switch is reset ● First step, select Diagnostics from Switch Web Server menu Schneider Electric - Division - Name – Date 4 Diagnostics Event Log Files ● Select Event Log from the Diagnostic menu to see the Event Log web page Schneider Electric - Division - Name – Date 5 Diagnostics Port Statistics ● The Port Statistics option provides the event counters for each of the switches ports. ● Select Statistics from the Port menu Schneider Electric - Division - Name – Date 6 Diagnostics Port Utilization ● Web page displays the network load of the individual ports. ● Select Utilization from the Port menu ● Use the Lower Threshold (%) and Upper Threshold (%) fields to enter lower and upper threshold monitor levels for each port ● An Alarm field check mark is set if the upper threshold (%) value is exceeded ● If the network load falls below the lower threshold value, the previously set check mark is removed Schneider Electric - Division - Name – Date 7 Diagnostics Topology Discovery ● Link Layer Discovery Protocol (LLDP), per the IEEE 802.1AB standard ● LLDP allows automatic detection of the network topology ● Connection information includes MAC address of the device and a port ID that is unique to this device ● The contents of the connection and management information includes: ● Chassis ID (its MAC address) ● ● ● ● Port ID (its port MAC address) Description of the port System name System description ● LLDP information enables network management station to map the topology of the network. Schneider Electric - Division - Name – Date 8 Diagnostics Topology Discovery ● Select Network Topology from the Diagnostics menu ● From the Configuration pull down menu, select operation On/Off ● Operation On: the Topology table will display the information from connected devices ● Operation Off: The network management stations and Ethernet configuration tool will not discover the switch Schneider Electric - Division - Name – Date 9 Diagnostics Port Mirroring ● With port mirroring, data traffic to one port (source) is copied to another port (destination). ● Allows the monitoring tool (RMON probe) to analyse traffic from the source port ● The destination port forwards data to be sent and blocks received data ● A typical port mirroring hardware configuration is shown below: Schneider Electric - Division - Name – Date 10 Diagnostics Port Mirroring ● The assignments for the source and destination ports can be defined through the selection shown below, as part of the switch web based configuration Schneider Electric - Division - Name – Date 11 Diagnostics Device Status ● The Web Page allows the selection of the functions to be monitored: ● Power Supply ● Switch Temperature ● Backup Memory Module Removed ● Connection Error ● HIPER-Ring ● Ring/Network Coupling ● Indicates the overall Device Status / Error Condition if any of the selected functions have detected an error ● The “Generate Trap” selection activates the sending of a trap if a function being monitored changes state Schneider Electric - Division - Name – Date 12 Diagnostics Device Status ● Select Device Status from the Diagnostic menu: Schneider Electric - Division - Name – Date 13 Diagnostics Device Status ● System alarm information is shown in the Device Status window on the System Web page Schneider Electric - Division - Name – Date 14 Diagnostics LED Indicators ● Front mounted LED indicators provide local status on the switch’s operation and status information ● Below are the indicators and their functions Indicator P RM Stand-By Fault Schneider Electric - Division - Name – Date Function Power On/Off Ring Manager active/ not active, redundant port enabled/ disabled Stand-By Mode enabled/not enabled Alarm Contact Open/Closed R1 Alarm Contact 1 Open/Closed R2 Alarm Contact 2 Open/Closed Fiber Ports Fiber Port Communication Status Copper Port Copper Port Communication Status 15 Diagnostics Fault Alarm Contact ● Normally Closed (NC) Relay Contact ● Alarm Contact “Opens” for any of the following conditions when selected to be monitored ● When one of the power sources fails or falls below threshold voltage level ● Loss of communication connection on 1 port ● Loss of ring redundancy reserve ● An error detected during the self-test Schneider Electric - Division - Name – Date 16 Diagnostics Signal Contact Options ● On the Signal Contact web page, you can select the switch conditions that will be monitored by the alarm contact. ● Includes a selection for manual contact operation where Open and Closed states can be set from the web page ● The Device Status selection monitors all components of the switch, deenergizing the contact if an error is detected ● Selecting Generate Trap will create a trap when alarm contact is deenergized Schneider Electric - Division - Name – Date 17 Diagnostics Signal Contact Options ● Select Signal Contact from the Diagnostics menu Schneider Electric - Division - Name – Date 18 Diagnostics Alarm (Traps) ● Lets you select the events in the Switch that will trigger an alarm (trap) and the management station (PC) where these alarms will be sent ● If you select Create Entry, you can enter the IP address of the management station. ● Alarm selections include: ● Authentication – Switch has rejected an unauthorized access attempt ● Link Up/Down – For 1 port on the switch, the link to a device has been established/interrupted ● Spanning Tree – The topology of the Rapid Spanning Tree has changed ● Chassis – Status of the components of the switch ● Redundancy – The status of the ring redundancy or the redundant ring/network coupling has changed ● Port Security – A switch port has received a data packet from an unauthorized device Schneider Electric - Division - Name – Date 19 Diagnostics Alarm (Traps) ● Select Alarm (Traps) from the Diagnostics menu Schneider Electric - Division - Name – Date 20 Diagnostics SNMP Traps ● Ability to immediately trap alarm conditions in the switch, not relying on a polling process. ● The trapped alarms can be sent to a management station that is defined in the switch configuration ● Alarms can be sent to a trap destination table configured via SNMP in the user defined management station Schneider Electric - Division - Name – Date 21 Diagnostics SNMP Traps ● The Network Management Station to which the traps are sent can be defined through the selection shown below, as part of the switch web based configuration. Schneider Electric - Division - Name – Date 22 Diagnostics SNMP Traps ● Selectable Alarm Triggering Events. User selected alarm triggering based on the following events. Schneider Electric - Division - Name – Date 23 Diagnostics IP Address Conflict Detection ● The ability to detect and eliminate IP address conflicts within the subnetwork that includes the switch. ● A web page allows the following selections: ● Enable - Selects both active and passive detection ● Disable – IP address conflict function is turned off ● Active Detection Only - If an IP address is detected, the switch will return to the previous ?, and make another attempt after 15 seconds ● Passive Detection Only - Listens passively to determine if the switches IP address already exists, and defends its address by employing the ACD (Address Conflict Detection) mechanism and sending out gratuitous ARPs. Schneider Electric - Division - Name – Date 24 Diagnostics IP Address Conflict Detection ● Select IP Address Conflict Detection from the Diagnostics menu ● From the Status pull down menu, select the Status Mode option ● Any IP address conflicts will be logged on the web page Schneider Electric - Division - Name – Date 25 Questions? Make the most of your energy Schneider Electric - Division - Name – Date 26