Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Observation of GRBs with the MAGIC Telescope Nicola Galante (MPI für Physik - München) for the MAGIC Collaboration 7 March 2008 Nicola Galante, DPG - Freiburg 1 Observations at VHE • BATSE: 2704 GRB up to ~2 MeV • EGRET: 4 GRBs above 1 GeV (up to 18 GeV) • No more detections above GeV (only 1 evidence of excess by MILAGRO) • (too) Many emission models • New phenomenology recently discovered (GRB late X-ray flares 103 - 104 s later) • VHE observations necessary to constrain models • GeV/TeV emission present in late activity? AGILE already in orbit, GLAST will be launched soon - GeV observations time! 7 March 2008 Nicola Galante, DPG - Freiburg GeV/TeV observation possible by new generation IACTs too 2 Constraints on IACT Isotropic GRB distribution: IACT Duty-Cycle ~10% Duration Short T90 < 2s, T90 0.7s, 1/3 Tot Long T90 > 2s, T90 30s, 2/3 Tot Fast repositioning time required! 7 March 2008 Nicola Galante, DPG - Freiburg 3 Constraints on IACT Band function valid up to GeV Ebreak 300 keV hard-to-soft evolution well described by Shock Synchrotron Model (SSM) moreover… Tavani M., Ap.J. 466, 768-778 (1996) 7 March 2008 Nicola Galante, DPG - Freiburg 4 Afterglow and redshift GRB970228: first fading X-ray counterpart by Beppo-SAX. From X to O up to several days adjacent galaxies: red-shift measurement 0.01 ≤ z ≤ 6.29 Jakobsson P., Levan A., et al., A&A 447, 897-903, 2006 7 March 2008 Nicola Galante, DPG - Freiburg 5 Interaction with EBL cosmological horizon Observed flux is attenuated zmax 1 for 50 GeV threshold K. Mannheim et al., A&A, 413,807-815 (2006) 7 March 2008 Nicola Galante, DPG - Freiburg 6 GRB Alarm System GC N Outside MAGIC systems Communication: •e-mail •web •Acoustic alarm 7 March 2008 Nicola Galante, DPG - Freiburg Alert System Central Control 7 The MAGIC Telescope high reflective diamond milled aluminum mirrors Active mirror control (PSF: 90% of light in o inner pixel) 0.1 o Light weight Carbon fiber structure for fast repositioning - 3.5 FOV camera - 576 high QE PMTs (QEmax= 30% 330 – 450 nm) Analog signal transport via optical fibers 7 March 2008 IPE IPE IPE NET CE 2-level trigger system & 2 GHz FADC system Nicola Galante, DPG - Freiburg 8 Sensitivity Since February 2007 a fast 2GHz Multiplexed FADC DAQ system is working improved sensitivity Current Sensitivity for E>300 GeV 1.57% Crab in 50 h 7 March 2008 Nicola Galante, DPG - Freiburg 9 Sensitivity Test on Crab Nebula: measured sensitivity as a function of observation time 70 GeV < E < 300 GeV ~3.6 Crab in 20 s 7 March 2008 Nicola Galante, DPG - Freiburg 10 Observed GRBs 2005-2006 GRB t0 Dtalert Dtoss t90 <ZA> 050421 04:11:52 58 s 108 s 10 s 50° 050502a 02:13:56 40 s 269 s 20 s 42° 050505 23:22:21 540 s 717 s 60 s 55° 050509a 01:46:29 16 s repointing 131 s 12 s Typical 050713a 04:29:02 050904 01:51:44 82 s 060121 22:24:54 060203 060206 7 March 2008 13 s 40 s s 40÷50 50° 70 s 49° 145 s 225 s 20° 15 s 583 s 2s 42° 23:55:35 171 s 259 s 83 s 44° 04:46:53 16 s 52 s 11 s 10° Nicola Galante, DPG - Freiburg 11 Two Prompt Emissions GRB 050713a GRB 050904 7 March 2008 Nicola Galante, DPG - Freiburg 12 Flux Upper Limits 2005-2006 GRB Eth Flux UL (30 min) 050421 212 GeV 0.2 CU 050502a 152 GeV 0.3 CU 050505 213 GeV 0.8 CU 050509a 215 GeV 0.4 CU 050713a 170 GeV 0.8 CU 050904 86 GeV 0.3 CU 060121 151 GeV 0.4 CU 060203 151 GeV 1.7 CU 060206 86 GeV 0.4 CU 7 March 2008 Nicola Galante, DPG - Freiburg 13 Flux Upper Limits 2006-2007 GRB t0 Dtalert Dtoss t90 <ZA> 060825 02:59:58 19 s 57 s 8s 28° 061028 01:26:22 140 s 169 s 106 s 38° 061217 03:40:08 13 s 786 s 0.4 s 56° 070412 01:27:03 674 s 701 s 34 s 35° 070920a 04:00:13 539 s 680 s 56 s 52° GRB Eth Flux UL (30 min) 060825 80-125 GeV 0.7 CU 061028 100-125 GeV 0.8 CU 061217 300-500 GeV 0.5 CU 070412 80-125 GeV 0.2 CU 070920a 225-300 GeV 0.4 CU 7 March 2008 Nicola Galante, DPG - Freiburg 14 Conclusions MAGIC features (TESTED!): Flux sensitivity: 3.6 Crab @ 5s LiMa in 20s @ 70 GeV < E < 300 GeV Angular resolution: 0.1° Slewing capabilities: 40÷50 s, ~20x than other Cherenkov Eth: 50 GeV at zenith, lowest attained E at Cherenkov Publishing GCN circular within 1 week! Paper on 2005-2006 observations already published J. Albert, et al., Ap. J. 667, 358, 2007 Measurements in VHE crucial but... ... need a near (but not so much) GRB! 7 March 2008 Nicola Galante, DPG - Freiburg 15 Fast Slewing Time! QuickTime™ and a Cinepak decompressor are needed to see this picture. 7 March 2008 Nicola Galante, DPG - Freiburg 16