Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory University of Arizona What is a Laser Tracker? Laser Tracker: Optical coordinate measuring machine • Projects a laser beam. Use two-axis gimbals to track the reflection from a corner cube • Measure 3-space position: – Two pointing angles – Radial distance • ADM (Absolute Distance Measurement) • DMI (Distance measuring interferometer) • SMR – Sphere Mounted Retroreflector (Faro) • Software converts from spherical coordinates Laser tracker components Three manufacturers of Laser Trackers • Leica Geosystems (Switzerland) • FARO (USA) • API (USA) 34” 21” 14” Laser tracker accuracy Assume advertised performance (all values are 2s) Define z as line of sight direction for tracker Uncertainty in position using ADM is Radial: Lateral m z 102 0.4 Lz m 2 m x y 182 3 Lz m x Lz 2 a q z For other directions, use vector projection a z cosq ) x sin q ) 2 (Out of plane, y, behaves the same as x.) 2 Calibration of laser tracker • Distance Measuring Interferometer gives < 0.1 µm/m accuracy – Typically limited by air temperature (1°C gives 1 µm/m error.) • Tracker repeatability is typically < 1 µm/m for all dimensions • The tracker can be calibrated for specific measurements using the DMI. – Radial : use DMI mode, moving the tracker ball – Lateral : use a second tracker in DMI mode • So it is possible to get micron level accuracy – – – – Need thermal control Control of geometry Careful calibration Average out noise Special advantages of the laser tracker • • • • Can achieve micron accuracy (so can CMM) Portable Measure over very large distances Can use optical tricks – Measure through fold mirrors – Measure through windows – Measure angles New Solar Telescope Big Bear Solar Observatory Off axis Gregorian, f/0.7 parent Use tracker to align mirrors in telescope Secondary mirror with SMRs at known positions wrt aspheric parent 1.7-m primary mirror with SMRs at known positions wrt aspheric parent Laser tracker Has view to all SMRs Measurement of NST secondary mirror Return sphere (CoC at F2) Focus 1 for ellipsoid Focus 2 for ellipsoid Interferometer SMRs Located by return into interferometer Laser tracker Optical table Flat mirror Ellipsoidal Secondary mirror Measurement of angle with tracker b2 a2 b Apparent ball position a a1) b1 The plane of the mirror is defined by - the line that connects the ball with its image - a point midway between the two balls Uncertainty in direction of flat mirror Uncertainty in mirror position (defined by its normal) a12 a2 2 a L b12 b2 2 b 2 Actual ball position (uncertainty a2, b2) Test of tracker through fold mirrors • Use high quality 12” flat mirror. Compare SMR measurements (actual and apparent). Calculate mirror normal • Measure mirror surface directly by touching the mirror with the SMRs • The two methods agree to within the 1 arcsec stability of the mirror Measurement of object’s 3D orientation • Fix 2 mirrors to the object at known angles • Determine mirror normal directions using the tracker • Determine objects 3D orientation in space SMR 1 Object to be measured Mirror 1 Mirror 2 SMR 2 Laser tracker Definition of mirror angles • 4 measurements : 2 normals, 2 DoFs each We get no information about rotation about the mirror’s normal • 3 unknowns (three space orientation) • Use least squares fit x A Mirror 1 O z Mirror 2 y B Sensitivity vs angle between mirrors Sensitivity for determining object’s 3-space orientation from measuring two mirrors as a function of the angle between the mirrors Inverse sensitivity, normalized Defined as ratio Uncertainty in angular measurements Uncertainty in determination of object’s orientation Interferometric testing primary mirror segments for the Giant Magellan Telescope Spherical mirror CGH 3.75 m diameter Tested in situ from floor 130 mm diameter M2 0.75 m diameter 23 m Interferometer Sam GMT segment Reference CGH Insert a CGH to test system PSM aligned to M2 3.8-m sphere Sam CGH Interferometer for GMT measurements M2 Use laser tracker to measure position of 3.8-m mirror wrt wavefront created by Sam 8.4 m diam off axis segment for Giant Magellan Telescope Defining CGH orientation in tracker coordinates 1. Fix mirrors, CGH, and SMRs to stable plate 2. Measure mirror orientation wrt CGH 3. Measure mirror normals with laser tracker Invar plate SMRs, used to give position CGH Prisms, used to fix reflective faces Measure mirror normals wrt CGH Autocollimator Rhomboid Pivot Linear grating on CGH substrate Use of laser tracker for system alignment CGH with flats Laser tracker SMR, seen directly and in reflection Using tracker through window Use Snell’s law at interfaces for angles Radial distance must include glass: OPD t n i i Apparent SMR position Actual SMR position Measure the window carefully Correct for it to determine actual SMR position Test of tracker looking through window • An SMR was measured directly at ~1 m • 1 cm thick window was inserted between the tracker and the SMR • The apparent SMR position was measured with the tracker • This was corrected for the refraction of the window • These tests showed agreement to 20 ppm, which is consistent with the noise levels of this test Conclusion • The laser tracker is great for general purpose metrology • It has some special capabilities that make it especially useful for optical alignment – – – – Follows the light through fold mirrors Can be calibrated to very high accuracy Can be used for measuring angle as well as position Can be used to measure through a window