IMAGE QUALITY SPATIAL RESOLUTION CONTRAST RESOLUTION RADIATION DOSE NOISE IMAGE ARTIFACTS Resolution in CT Spatial Resolution Contrast Resolution SPATIAL RESOLUTION • DEGREE OF BLURRING IN THE IMAGE MEASURE OF THE ABILITY TO DISCRIMINATE OBJECTS OF VARYING DENSITY A SMALL DISTANCE APART AGAINST A UNIFORM BACKGROUND MTF MODULATION TRANSFER FUNCTION MOST COMMONLY USED TO DESCRIBE SPATIAL RESOLUTION IN CT MTF • MTF OF 1 – 100% TRANSFER OF OBJECT TO IMAGE • MTF OF 0 – 0% TRANSFER OF OBJECT TO IMAGE HIGH CONTRAST PHANTOM FACTORS AFFECTING SPATIAL RESOLUTION • • • • • • SLICE THICKNESS FOCAL SPOT SIZE DETECTOR WIDTH TYPE OF CONVOLUTION FILTER (KERNEL) MATRIX SIZE FOV SLICE THICKNESS SLICE THICKNESS 5 MM S. RESOLUTION 1 MM FOCAL SPOT SIZE FOCAL SPOT SIZE S. RESOLUTION LARGE FOCAL SPOT = LARGE PENUMBRA (BLURR) DETECTOR WIDTH DETECTOR WIDTH S. RESOLUTION TYPE OF CONVOLUTION FILTER SHARP KERNEL SMOOTH S. RESOLUTION SHARP MATRIX SIZE MATRIX SIZE 80 X 80 S. RESOLUTION 512 X 512 DFOV SIZE DFOV 20CM S. RESOLUTION 10CM CONTRAST RESOLUTION • SENSITIVITY OF THE SYSTEM • LOW CONTRAST RESOLUTION • LOW CONTRAST DETECTIBILITY LOW CONTRAST RESOLUTION ( TISSUE RESOLUTION) • THE ABILITY OF AN IMAGING SYSTEM TO DEMONSTRATE SMALL CHANGES IN TISSUE CONTRAST CONTRAST RESOLUTION • SENSITIVITY OF THE SYSTEM • LOW CONTRAST RESOLUTION • LOW CONTRAST DETECTIBILITY CONTRAST RESOLUTION PHANTOM FACTORS AFFECTING LOW CONTRAST RESOLUTION • • • • • • • PHOTON FLUX SLICE THICKNESS PATIENT SIZE DETECTOR SENSITIVITY RECONSTRUCTION ALGORITHM IMAGE DISPLAY QUANTUM NOISE PHOTON FLUX (INTENSITY) PHOTON FLUX mAs kVp C. RESOLUTION P. FLUX P. FLUX LOW TECHNIQUE ADEQUATE TECHNIQUE SLICE THICKNESS SLICE THICKNESS 8 mm C. RESOLUTION 5 mm 10 mm – 100 PHOTONS 5 mm – 50 PHOTONS PATIENT SIZE PATIENT SIZE NORMAL C. RESOLUTION LARGE DETECTOR SENSITIVITY DETECTOR SENSITIVITY C. RESOLUTION TYPE OF CONVOLUTION FILTER SMOOTH KERNEL SMOOTH C. RESOLUTION SHARP IMAGE DISPLAY MONITOR RESOLUTION C. RESOLUTION QUANTUM NOISE QUANTUM NOISE HIGH NOISE C. RESOLUTION LOW NOISE NOISE IN CT • FLUCTUATION OF CT# BETWEEN POINTS IN THE IMAGE FOR A SCAN OF UNIFORM MATERIAL SUCH WATER. NOISE SOURCES IN CT • QUANTUM NOISE – X-RAY INTENSITY AT THE DETECTORS • MATRIX SIZE • DFOV • SLICE THICKNESS • CONVOLUTION FILTER TYPE • PITCH QUANTUM NOISE – CONTROLLED BY THE TECHNOLOGIST • mA • Time • kVp NOISE NOISE • QUANTUM (STATISTICAL) – CONTROLLED BY THE TECHNOLOGIST • ELECTRONIC – INHERENT IN THE EQUIPMENT QUANTUM NOISE – CONTROLLED BY THE TECHNOLOGIST • • • • DFOV MATRIX COLLIMATION FILTER SPATIAL FREQUENCY • PITCH NOISE DOSE vs IMAGE QUALITY • RADIATION DOSE IMAGE QUALITY