* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Download Volume 7, Issue 2, March-April 2016, pp. 91–100, Article ID:... Available online at
Standing wave ratio wikipedia , lookup
Radio transmitter design wikipedia , lookup
Power MOSFET wikipedia , lookup
Standby power wikipedia , lookup
Audio power wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power electronics wikipedia , lookup
Captain Power and the Soldiers of the Future wikipedia , lookup
International Journal of Advanced Research in Engineering and Technology (IJARET) Volume 7, Issue 2, March-April 2016, pp. 91–100, Article ID: IJARET_07_02_009 Available online at http://www.iaeme.com/IJARET/issues.asp?JType=IJARET&VType=7&IType=2 Journal Impact Factor (2016): 8.8297 (Calculated by GISI) www.jifactor.com ISSN Print: 0976-6480 and ISSN Online: 0976-6499 © IAEME Publication ___________________________________________________________________________ LOAD BALANCING AND POWER FACTOR CORRECTION FOR MULTIPHASE POWER SYSTEMS V. K. Tripathi Department of Electrical Engineering SHIATS, Allahabad, Uttar Pradesh Prof. (Col.) G. Singh CSED SHIATS, Allahabad, Uttar Pradesh ABSTRACT In recent years the area of multi-phase (phase order more than three) machines is popular. A multi-phase source may be derived from transformer connection (3- phase to 4-phase) or by DC link 4-phase inverters. There are problem of unbalance, harmonic distortion and poor power factor operation. This paper proposes the supply side load balancing and power factor correction .The proposed compensation scheme uses the shunt current source compensation whose instantaneous values are determined by the instantaneous symmetrical component theory. An ideal compensator in place of physical realization of the compensator has been proposed in form of a current controlled voltage source inverter. The compensation schemes developed in the paper are tested for their validity on 4-phase (4-wire & 5wire) circuits through extensive simulations. Index Terms: Multi-Phase, Power Factor Correction, Compensator, Load Balancing Cite this Article: V. K. Tripathi and Prof. (Col.) G.Singh. Load Balancing and Power Factor Correction for Multiphase Power Systems. International Journal of Advanced Research in Engineering and Technology, 7(2), 2016, pp. 91–100. http://www.iaeme.com/IJARET/issues.asp?JType=IJARET&VType=7&IType=2 http://www.iaeme.com/IJARET/index.asp 91 [email protected] V. K. Tripathi and Prof. (Col.) G.Singh 1. INTRODUCTION Multi-phase Power systems have several inherent benefits such as reduced torque pulsation, harmonic content and current per phase without increasing the voltage per phase, higher systems higher reliability and increased power in the same frame as compared to their three-phase counterpart. So Multi-phase inverter fed induction motor drives (especially 4-phase) are suitable for high power ratings and other specialized applications. However the use of such multi drives and devices may be effected by phase outages & unbalanced as well as nonlinear loading. Such conditions may lead to many undesirable effects on the supply system such as additional losses in connecting lines and interfacing devices, oscillatory torques in ac machines, increased ripple in rectifiers, malfunctioning in sensitive equipments, harmonic and excessive neutral currents etc. It is therefore desired to have the balanced power system operation with minimum lower order harmonics. A number of methods have been evolved for the compensation of harmonics and unbalances for the conventional three phase systems. Generally These methods are based on the instantaneous reactive power theory , theory of symmetrical components , and reference frame theory Utilizing these theoretical concepts, techniques have been developed for load balancing and power factor correction .This paper addresses the problem of balancing of an unbalanced 4-phase (Multiphase) load and power factor correction on supply side. The proposed compensation methods have been verified by simulation studies. 2. COMPENSATION SYSTEM It is assumed that an ideal voltage source is connected to an arbitrary load ZL, drawing unbalanced current from the source. In Order to make the source currents balanced, an external controlled current source called compensator is proposed to be connected to the load as shown in Fig.1.The point of connection of compensator to power system is called point of common connection (PCC). The proposed compensation scheme can be applied to both four-phase four-wire and four-phase five-wire power system. In four-phase four-wire star connected load, the common point of the load ‘n’ is isolated from ‘N’, the common point of source. On the other hand, in four-phase five-wire system, the neutral point is formed by connecting the nodes ‘n’ and ‘N’ and is also connected to the compensator at its common point n as shown in fig(1).This has the advantage that the compensator currents ica, icb, icc & icd are currents in independent circuits, and each phase of the compensator can supply currents independent of the other three phases. Figure 1 Compensation scheme for 4-phase star connected load. http://www.iaeme.com/IJARET/index.asp 92 [email protected] Load Balancing and Power Factor Correction for Multiphase Power Systems 3. INSTANTANEOUS SYMMETRICAL COMPONENTS THEORY Following the unbalanced four phasors of a four-phase system can be resolved into the four component systems of balanced phasors known as: The zero sequence system (zero phase differences); First- (positive) sequence system (four phasors are displaced 90 deg. relative to each other). The second-sequence system (two phasors are displaced 180 deg. relative to each other, each representing two phases, constituting two 2-phase zero sequences in opposition); Third-(negative) sequence systems (sequence in the opposite sense of rotation to that of the first sequence system) The positive sequence components of balanced four phase currents Ial, Ib1, Ic1, Id1 have original phase sequence like the original unbalanced four-phase currents. These other three sets of components are shown in Fig. 2.below. Iao Ibo Ico Ido (a) Zero sequence system Ia1 Id1 Ic1 Ib1 (b) First (positive sequence)system (c) Second sequence system http://www.iaeme.com/IJARET/index.asp 93 [email protected] V. K. Tripathi and Prof. (Col.) G.Singh (d) Third (Negative sequence) system Fig. 2 Symmetrical Components of Four-Phase System As the original unbalanced four-phase phasors are resolved into four components, the components when they are added yield the original phasors. Therefore Ia Ib Ic Id I a1 I a 2 I b1 I b 2 I c1 I c 2 I d1 I d 2 I a3 I a0 I b3 I b0 I c3 I c 0 I d 3 I d 0 (1) A. Four phase operator m Now let the four phase complex operator m be defined as, exp j / 2 0 j1.0 m m2 1 m3 Figure 3 phasor diagram and the various power of operator m. Some of the properties of operator 'm' are summarized in equation. (2) m 1900 0 J1.0 m2 1 1800 1 J 0.0 m3 12700 0 J1.0 1 m m2 m3 0 http://www.iaeme.com/IJARET/index.asp (2) 94 [email protected] Load Balancing and Power Factor Correction for Multiphase Power Systems B. Transformation The symmetrical components of a four phase system may be represented in matrix form by equation. (3) Ia 1 1 Ib 1 m3 Ic 1 m2 1 Id 1 m 1 m2 1 m2 1 Ia0 m1 Ia1 m2 Ia2 m3 Ia3 (3) The inverse relationship of equation (3) may be written as 1 1 Ia Ia0 1 1 Ia 1 m m2 m3 Ib 1 1 (4) 4 1 m2 1 m2 Ic Ia2 3 2 1 m m m Id Ia3 With the conventional rotation of current vectors in counter clockwise direction, the instantaneous value of the currents can be expressed as follows. 1 1 Ia0 Ia 1 1 Ib 1 m3 m2 m1 Ia 1 Ic 1 m2 1 m2 Ia2 1 2 3 Id 1 m m m Ia3 (5) The vectors ia1 and ia3 are complex conjugate to each other and ia0 is a real quantity. The neutral current - in ia ib ic i d will be non zero if instantaneous current phasors are unbalanced and is also equal to 4ia0. The instantaneous symmetrical component va0, a1, va2 and va3 of phase voltage va can be written in term of va , vb , vc , vd as following equation (6) a 0 1 1 v a1 1 1 m 4 1 m 2 va 2 3 1 m va 3 1 m2 1 m2 1 va m3 vb m 2 vc m 2 vd (6) 4. CALCULATION OF COMPENSATOR CURRENTS The Compensator current is calculated on the basis of instantaneous symmetrical component analysis of the load current. An explicit relation for the reference current is derived in this section by applying multi-phase instantaneous power symmetrical component transformation. A compensated source will have balanced supply currents and therefore its zero sequence components will be zero. That is, isa isb isc isd 0 http://www.iaeme.com/IJARET/index.asp (7) 95 [email protected] V. K. Tripathi and Prof. (Col.) G.Singh The balanced phase currents at desire power factor angle can be translated with the help of (5) and (6) into another equation (8) i Vsa mvsb m2vsc m3 vsd sa misb m isc m isd 2 3 (8) The instantaneous power in a 4-phase 5-wire system is given by- Vsa isa Vsb isb Vsc isc vsd isd plavg Solving (8), by taking m e We obtain - (9) J 2 2 ( A B) (10) Where, A Vsa JVsb , B isa J isb taking tangent on both sides of (10) the following relation is obtained. Vsb isa Vsa i sb Vsa isa Vsb i sb (11) Where tan 2 Finally; Vsa Vsb 2 Vsa2 Vsb2 V Vsa sb 2 2 Vsa Vsb2 V Vsb sa 2 2 Vsa Vsb2 V Vsa sb 2 2 Vsa Vsb2 ica ila icb ilb icc ilc icd ild Plavg Plavg Plavg Plavg (12) 5. SIMULATION RESULTS The proposed compensation scheme for four-phase system has been verified by simulation. In this section, the simulation results will be presented and discussed. A. Four-phase five wire system The system shown in Fig.1 has the following specifications. The voltages vsi i a, b, c, d and impedances Z i a, b, c, d ) are given below- vsi 320.25 sin( 100t i * / 2) respectively (13) i 0,1, 2, 3 Corresponds to phase a, b, c, d Z a 10 j12, Z b 10 j19 Z c 10 j18, Z d 05 j 04 http://www.iaeme.com/IJARET/index.asp (14) 96 [email protected] Load Balancing and Power Factor Correction for Multiphase Power Systems In the simulation results, the system works with unbalanced load for one cycle (0.03 sec) and runs for another five cycle (0.02 sec) with the proposed compensators. It can be seen from Fig.4 (b) and Fig. 4 (c) that the source currents (isp p a, b, c, d ) and load currents ( ilp p a, b, c, d ) are equal and unbalanced When Compensator is off currents (icp(p=a,b,c,d)) become unbalanced accordingly as shown in Fig.4(d). Figure 4 4-phase 5-wire supply system with and without compensator The instantaneous powers (source & load powers) and neutral currents (source & load neutral currents) are plotted in Fig. 5. It can be seen from Fig. 5(a) that before compensation, that is, when compensator is switched off, source power ( Ps) and load power (Pl) are equal in magnitude and oscillating in nature due to unbalance in load currents. But after compensation when compensator is turned on the oscillating component of power in source attains a steady state value as can be seen from Fig. 5 (a) while load power is oscillating in nature as shown in Fig. 5 (a). The power developed in the compensator (Pc) during its presence is also found unbalanced and shown in Fig. 5(c).Moreover, the source neutral current ( isN) attains zero value when the compensator is turned on and can be seen from Fig. 5(b) as it balances the source currents. It can thus be inferred that the sum of the instantaneous compensator currents is equal to load neutral current (i l n). Figure 5 variation of power and neutral current for 4-phase 5- wire supply system The variation of co-phasors-voltage and currents shows unity power factor operation with compensator as it is evident from Fig. 6 It can be seen from (18) that impedances are unbalanced and have reactive elements, but the currents are not only balanced but also operate at unity power factor with compensator http://www.iaeme.com/IJARET/index.asp 97 [email protected] V. K. Tripathi and Prof. (Col.) G.Singh Figure 6 (a)-(d) (1:10) scaled source voltage (solid line) source currents (dashed line) load currents (hard solid line) 5- wire supply system. B. Load compensation for phase outages The multiphase loads like motor capability to operate with phase outages and it has degraded performance source sees an unbalanced operation and therefore other loads connected to such a source get affected. The proposed Compensator can be used for load compensation for phase outages satisfactory. The results are shown in Fig.7 to Fig.8 Figure 7 Variation of load currents, source currents and compensator currents when two phase (a, b) are out (from load side) from 4-phase 5-wire system Figure 8 Variation of power and neutral current for the phase outage (a ,b) of load for 4phase 5-wire supply system http://www.iaeme.com/IJARET/index.asp 98 [email protected] Load Balancing and Power Factor Correction for Multiphase Power Systems It is found that from fig (7) and fig (8) that the source currents and power are balanced When Compensator is on. 6. CONCLUSION A method for load balancing and power factor correction on source side for 4-phase (multiphase) load circuit is Proposed In this paper The proposed scheme has been found to be suitable for unbalanced loading and phase outage source voltages, load currents, source currents, neutral currents and compensator currents has been observed during non-compensating and compensating period. The variations of the load, source and compensator powers are analyzed. It can be concluded that 4-phase (multi-phase) system equipped with multi-phase compensator can work with phase outages and unbalanced loading. REFERENCES [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] E. A. Kiligshim and C.M. Ong, High phase order induction motors- Part-IDescription and theoretical considerations, IEEE PAS-102, no.1 pp. 47-53, 1983 E. A. Kiligshim and C.M. Ong, High phase order Induction motors-Part-IIExperimental results, IEEE PAS- 102, no.1, pp.54-59, 1983 Y. Zhao, and T.A. Lipo, Modelling and control of multiphase induction machine with structural unbalance, Part- I-Machine modeling and multidimensional current regulation, IEEE Trans, Energy conversion, EC-11, no. 3, pp. 570-577, 1996. H. A. Toliyat and H. Xu, A novel direct torque control (DTC) method for five phase induction machine Proc. Applied Power Electronics conference & Symposium (APEC)-2000, Annual IEEE Conf., pp.162-168, 2000. C. B. Jacobina, C. César de Azevedo, A. M. N. Lima, and L. A. Ribeiro, Online estimation of the stator resistance and leakage inductance of a fourphase induction machine drive, IEEE Trans. On Power Electronics, vol. 19, no. 1, pp. 10-15, 2004. J.Apsley and S. Williamson, Analysis of multiphase induction machine with winding faults, IEEE Transactions on industry applications, vol. 42, no.3, pp. 465-472, 2006. H. Akagi,Y. Kanazawa, K. Fugita and A. Nabe, Generalized theory of instantaneous reactive power and its application, Electrical Engg. in Japan, vol. 103, no.4, pp. 58-66, 1983. H. Akagi, Y. Kanazawa and A. Nabe, Instantaneous reactive power compensators comparing switching devices without energy storage components, IEEE Trans. Ind. Appl., vol. 1A-20, no.3, pp. 625-630, 1984. H, Akagi, A. Nabe and S. Atosh, Control strategy of active power filters using multi voltage-source PWM converter, IEEE Trans. Ind. Appl. vol.1A22, no.3, pp. 460-465, 1986 M. Z. Elsadek, Balancing of unbalanced loads using static var compensators, Electr. .Pow. Syst. Res., (12), pp. 137- 148, 1987. H. Watanabe, R. M. Stephan and M. Aredes, New concepts of instantaneous active and reactive powers in electrical sy|stems with generic loads, IEEE Trans. On Power Delivery, vol. 8, no. 2, pp. 697-703, 1993. A. Kern and G. Schroder, A novel approach to power factor control and balancing problems, Proc. , IEEE, IECON, 428-433, 1994 http://www.iaeme.com/IJARET/index.asp 99 [email protected] V. K. Tripathi and Prof. (Col.) G.Singh [13] [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] M. Adres and E.H. Watana, New control algorithms for series and shunt three-phase four wire active power filters, IEEE Trans. Power Delivery, vol., 10, no. 3, pp.1649-1656, 1995 Peng and J.S. Lai, Generalized instantaneous reactive power theory for threephase power systems, IEEE Trans. Instrumentation and measurement, vol. 45, no.1, pp. 293- 297, 1996. F. Z. Peng, G.W. Ott, Jr., and D.J. Adams, Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase fourwire systems, IEEE Trans. on power electroics, vol. 13, no. 6, pp. 1174-1181, 1998. P. Verdelho G.D. Marques, A neutral current electronics compensator, IEEE, IECON 98, pp. 831-936, 1998. V. Cardenas, N. Vazquez, C. Hernandes, S. orta, Analysis and design of a three-phase sliding mode controller for a shunt active power filter, IEEE power electronics specialist conference-PESC'99, pp. 236-241, 1999 A. Ghosh, A. Joshi, A new approach to load alancing and power factor correction in power distribution system, IEEE Trans. On power delivery, Vol. 15, No.1, 2000, pp. 417-422. S. V. Vazuez, J.A. Sanchez, J. M. Carrasco, J. I. Leon and E. Galvan, A model-based direct power control for three phase power converter, IEEE Ttans. On Ind. Electronics, vol. 55, no.4, pp. 1647-1657, 2008 ZakirHusain,R.K.Singh,S.N.Tiwari, Load Balancing and Power factor Correction for four phase (Multiphase) using Novel Algorithm IEEE. Lopamudra Mitra, Dr C.K.Pangrahi, Power Factor Improvement Using Active Power Factor Correction Methods. International Journal of Electrical Engineering &Technology, 1(1), 2010, pp. 32–46. Prabodh Kumar Khampariya, Asfaque Khan, Dr.Amita Mahore, The Design and Implementation of A Single-Phase Power Factor Correction Circuit. International Journal of Electrical Engineering &Technology 3(2), 2012, pp. 204–209. Zakir Husain, R.K.Singh, S.N.Tiwari, A Novel Algorithm for four phase (Multiphase) source side load balancing and power factor correction IJRTE,Vol1,2009. http://www.iaeme.com/IJARET/index.asp 100 [email protected]