Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Compact I/O Modules XIO Family Sales Presentation XIO Compact I/O Family Features • XIO Compact I/O are distributed I/O for use with the Honeywell XL5000 product line. - Additional I/O for XL50 or XL500 controllers - Easy installation via LNS Plug-in - Small profile allows for installation in otherwise hard to reach areas • The XIO Compact I/O family fills out Honeywell’s already robust distributed I/O offering - XIO Compact I/O - XFL Distributed I/O - XFC Smart I/O 2 OS Number Applications XIO-10DI 10 Digital Inputs XIO-4DI 4 Digital Inputs XIO-4DO 4 Digital Outputs XIO-8AI 8 Analog Inputs XIO-4NTC 4 20KΩ NTC Inputs XIO-4PT1000 4 Platinum 1000 Inputs XIO-4AO 4 Analog Outputs XIO-10HUB Hub expander module XIO Compact I/O The XIO Compact I/O offers these distinguishable features: • Easy installation - DIN rail mounting - Only 2 twisted pair wires for up to 15 modules. Run 24VAC and Lon Network cable to first module then link 14 more to the first • Easy to expand - Pick and chose the right number of I/O for each job. No longer have unused I/O on the job • Eye-pleasing form factor - No complex buttons or switches • Compact - Very small profile. Install in places other modules couldn’t fit • Save time and money - No need to run extra wire for 24VAC and Lon network saves labor time and wire costs • Range of input and output types and sensors - 8 Modules: DI, DO, AI, AO and a HUB expander module 3 Opens Up New Markets • The XIO can help you open doors with New Contractor’s: - Bring to any open Lon system contractor - Use as a door opener – the XIO will already work with their system • Start with the XIO and come back to talk about valves and actuators - Once you have their attention with the XIO you have a reason to make a second call Valves Actuators Building Controls 4 Nomenclature Family Designation XIO = Compact I/O Number of Inputs/Outputs 4 = 4 total inputs or outputs 8 = 8 total inputs or outputs 10 = 10 total inputs or outputs XIO - 8AI Input/Output Type DI = Digital Input DO = Digital Output AO = Analog Output AI = Analog Input NTC = Specific 20KΩ NTC Analog Input PT1000 = Specific Platinum 1000 Analog Input HUB = Free Contacts 5 Compact I/O Modules XIO Family Module Descriptions XIO-10DI • Typical Applications - Pump Status, Power status, Freeze Status • LON module with 10 digital inputs • Record the status of potential free switches (dry contacts) - electronic limit switches at vent valves or auxiliary contacts at power contactors - record counted measurands at counters with contactor. • Terminals 1 - 10 and the C (common) input contacts can be connected to potential free switches (dry contacts) • States and counted measurands are read out by standard network variables and bound to XL500 or XL50 controllers • Configuration is done by LNS® Plug-in 7 XIO-4DI • Typical Applications - Pump Status, Power status, Freeze Status • LON module with 4 digital inputs • Record the status of potential free switches (dry contacts) - electronic limit switches at vent valves or auxiliary - contacts at power contactors record counted measurands at counters with contactor • Terminals 1 - 4 and C (common) input contacts can be connected to potential free switches (dry contacts) • States and counted measurands are read out by standard network variables and bound to XL500 or XL50 controllers • Configuration is done by LNS® Plug-in 8 XIO-4DO • Typical Applications - Start up a remote device such as packaged boiler exhaust fans and remote pumps • LON module with 4 digital outputs • Switch electrical components - motors, contactors, lamps, blinds etc. • Relays activated by standard network variables • Manual control override function that is only activated in the "Configured Mode" • Configuration is done by LNS® Plug-in 9 XIO-8AI • Typical Applications - Remote sensors such as Outdoor Air Temperature, hot water loop temps at the end of a loop, differential pressure that is 2/3 of the way down the system, outside humidity, enthalpy, monitor room temperatures using 1 XIO-8AI per floor. • LON module with 8 configurable temperature or voltage analog inputs • Record temperatures and voltages of passive and active sensors - electrical ventilation and mixing valves, valve positions • Different formats can be read out depending on the setting for each input, and bound to other LonMark® devices - Temperature, resistance, percentage and voltage • Supply voltage for active sensors can be provided by the module. • Configuration is done by LNS® Plug-in 10 XIO-4NTC • Typical Applications - Same as XIO-8AI but for 20K NTC sensors only - More accurate at the normal operating range • LON module with 4 specific analog inputs for 20K NTC sensors • Inputs can be scanned simultaneously by standard network variables, SNVT 11 XIO-4PT1000 • Typical Applications - Same as 8AI but for PT1000 sensors only - More accurate at extreme ranges • LON module with 4 specific analog inputs for Platinum 1000 sensors • Inputs can be scanned simultaneously by standard network variables, SNVT 12 XIO-4AO • Typical Applications - Control a VFD for an exhaust fan. Control for a cooling tower fan, remote pumps, and speed control • LON module with 4 analog outputs • Outputs are activated proportionally by the network variables, SNVTs • Provide a voltage between 0 and 10 Volts • Outputs can be set to a previously defined value depending on a binary state • Manual overrides included • Configuration is done by LNS® Plug-in 13 XIO-10HUB Extension Module • Typical Applications - Used primarily with XIO-10DI. See figure at right • Provides additional potential free contacts as supporting contacts to connect digital outputs, analog outputs, etc. • Six contacts each are interconnected. • A maximum of 60 volts can be applied to the contacts. • The extension module can be used as a power on module for bus connection, supply voltage and potential distribution. 14 Selling Points • Easy installation - Small footprint - Easily Expandable Link up to 15 different modules together with jumper clip. No need for extra wire for power and network - Lower I/O count than XFL and XFC: less unused I/O on the job - DIN rail mounting 15 Compact I/O Modules XIO Family System Setup System Setup • The XIO do not have processing power of their own and must be bound to one of the following controllers XL50 XL500 Smart 17 XL500 XL50 XL50 XIO-10HUB XIO-10DI Lon Bus XIO-4AO 18 XIO-4DI XIO-4DO XIO-4NTC XIO-4PT1000 XIO-8AI XL500 XL500 XIO-10HUB XIO-10DI Lon Bus XIO-4AO 19 XIO-4DI XIO-4DO XIO-4NTC XIO-4PT1000 XIO-8AI XL500 Smart XL500 Smart XIO-10HUB XIO-10DI Lon Bus XIO-4AO 20 XIO-4DI XIO-4DO XIO-4NTC XIO-4PT1000 XIO-8AI Compact I/O Modules XIO Family I/O Comparison and Selection Guide I/O Comparison Compact I/O XIO-4DI Digital Inputs Digital Outputs Analog Inputs 4 XIO-8AI 8 XIO-4AO 4 10 XIO-4PT1000 4 XIO-4NTC 4 Digital Inputs Digital Outputs XFC3A06001 4 4 4 2 XFC3D06001 4 4 4 2 Digital Inputs Digital Outputs Distributed I/O XFL521B XFL524B 22 Analog Inputs Analog Inputs Analog Outputs Analog Outputs 8 XFL522B XFL523B Compact I/O are stand alone with one type of I/O on each module. You do not need to purchase separate pieces to make a working I/O module. Provides additional free contacts XIO-10HUB Smart I/O Comments 4 XIO-4DO XIO-10DI Analog Outputs 8 12 6 Comments Smart I/O are stand alone. Unlike the Compact I/O, the Smart I/O has multiple types of I/O on each module. Comments Compact I/O are not stand alone. They require multiple pieces be put together to create a working I/O module. Please refer to the next slide for what to purchase to create a complete I/O module. XFL Distributed I/O Selection Guide Select the type of I/O module you wish to use in the first column. Then follow that row to the right, anything that is marked is also needed to create a fully functional I/O module. XFR522A XFR524A XSL513 XSL514 XSL511* Manual Override Switches for the XFL522B Manual Override Switches for the XFL522B Terminal Block for XFL521B, XFL522B, XFL523B Terminal Block for XFL524B Lon Network Interface XFL521B Analog Input Module X X* X X* X X* XFL 522B Analog Output Module Optional if manual override is desired XFL523B Digital Input Module XFL524B Digital Output Module Optional if manual override is desired X X* *If more than one Distributed I/O module is linked together than only one XSL511 is needed for that grouping Up to 8 distributed I/O modules can be linked to one XSL511 23 Compact I/O Modules XIO Family Pricing Pricing Compact I/O Trade Base Price XIO-4DI $465 XIO-4DO $465 XIO-8AI $705 XIO-4AO $505 XIO-10DI $505 XIO-4PT1000 $490 XIO-4NTC $490 XIO-10HUB $75 Smart I/O XFC3A06001 $723.84 XFC3D06001 $774.33 Distributed I/O 25 Trade Base Price Trade Base Price XFL521B $484.81 XFL522B $484.81 XFL523B $484.81 XFL524B $484.81 XFR522A $192.27 XFR524A $192.27 XSL 511 $85.44 XSL513 $161.75 XSL514 $161.75 Price Per I/O Compact I/O I/O Count Trade Base Price XIO-4DI 4 $465 $116.25 XIO-4DO 4 $465 $116.25 XIO-8AI 8 $705 $88.13 XIO-4AO 4 $505 $126.25 XIO-10DI 10 $505 $50.50 XIO-4PT1000 4 $490 $122.50 XIO-4NTC 4 $490 $122.50 XIO-10HUB Smart I/O Provides additional Free contacts and is not an I/O module I/O Count Trade Base Price Price Per I/O XFC3A06001 14 $723.84 $51.70 XFC3D06001 14 $774.33 $55.31 Distributed I/O 26 Price Per I/O Trade Base Price* I/O Count *Price includes Subbase and Network Card Price Per I/O XFL521B 8 $732.00 $91.50 XFL522B 8 $732.00 $91.50 XFL523B 12 $732.00 $61.00 XFL524B 6 $732.00 $122.00 Compact I/O Modules XIO Family Product Launch Activities Launch Materials • Launch date: July 17, 2006 • Collateral - I/O Modules Quick Selection Guide - Compact I/O Modules Brochure - Distributed I/O Modules Brochure - Smart I/O Modules Brochure - I/O Module Poster - Postcard to Contractors • Sample unit to sales reps and Diamond Distributors • Webcast to Distributors and Contractors 7/10 (with ZonePRO Webcast) 28 Technical Literature INSTALLATION INSTRUCTIONS 95-7720 XIO-10DI Installation Instructions 95-7717 XIO-10HUB Installation Instructions 95-7718 XIO-4AO Installation Instructions 95-7714 XIO-4DI Installation Instructions 95-7719 XIO-4DO Installation Instructions 95-7727 XIO-4NTC Installation Instructions 95-7728 XIO-4PT1000 Installation Instructions 95-7716 XIO-8AI Installation Instructions PRODUCT DATA (Not Currently Available) 74-4043 Product Data 95-7733 Operating Guide PRESENTATIONS 29 Sales Presentation The one you are currently watching Technical Presentation Comes with Launch Materials Compact I/O Modules XIO Family Operation with WEBs Honeywell WEBS • Currently XIO is only available to be programmed with CARE through LNS Plug-in. • Workbench Wizard and .lmnl files will be introduced shortly to configure with WEBs more easily WEBs Controller XIO-10HUB XIO-10DI Lon Bus XIO-4AO 31 XIO-4DI XIO-4DO XIO-4NTC XIO-4PT1000 XIO-8AI www.honeywell.com