Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits Advantages of polyphase circuits Three Phase Connections Basic configurations for three phase circuits Source/Load Connections Delta-Y connections Power Relationships Study power delivered by three phase circuits Power Factor Correction Improving power factor for three phase circuits THREE PHASE CIRCUITS Van 3 phase voltage Vbn Vcn 0 120 240 Instantaneous Phase Voltages van (t ) Vm cos( t )(V ) vbn (t ) Vm cos( t 120)(V ) vc (t ) Vm cos( t 240)(V ) Vm 120 2 a a + _ V0 Wye Connected Source n _ V-240 + c _ V-120 + b b c Delta Source a a _ + + Delta Source _ Vbc = Vab -120 b c _ Vab = | Vab | 0 b + c Vca = Vab -240 Wye – Wye System a A Zl ZL n N ZL c b B Zl Zl ZL C Delta – Delta System a A Zl + ZL ZL _ + c _ _ + b B Zl Zl C ZL Delta – Wye System a A Zl _ ZL + + _ ZL c _ + b B Zl Zl ZL C a a A I aA I AB + _ I CA V0 Z Z n _ V-240 + _ I BC V-120 + b b c C B Z c Vcn - Vbn Vab 30 o Van Vbn Vab = Van - Vbn Vab = 3 Van 30o Vab Van Vbn | V p | 0 | V p | 120 | V p | 1 (cos120 j sin 120) 1 3 | V | p | V p | j 2 2 3 | V p | 30 Vbc 3 | V p | 90 Vca 3 | V p | 210 VL 3 | V p | Line Voltage I CA I aA = 3 I AB -30o I AB I aA I BC - I CA INSTANTANEOUS POWER Instantaneous Phase Voltages van (t ) Vm cos( t )(V ) Balanced Phase Currents ia (t ) I m cos( t ) vbn (t ) Vm cos( t 120)(V ) ib (t ) I m cos( t 120) vc (t ) Vm cos( t 240)(V ) ic (t ) I m cos( t 240) Instantaneous power p(t ) van (t )ia (t ) vbn (t )ib (t ) vcn (t )ic (t ) Theorem For a balanced three phase circuit the instantaneous power is constant p( t ) 3 Vm I m cos (W ) 2 REVIEW OF Y Transformations Ra R1 R2 R1 R2 R3 Rb R2 R3 R1 R2 R3 Rc R3 R1 R1 R2 R3 Y R1 Ra Rb Rb Rc Rc Ra Rb R2 Ra Rb Rb Rc Rc Ra Rc R3 Ra Rb Rb Rc Rc Ra Ra Y REVIEW OF Rab R2 || ( R1 R3 ) Y Transformations Y Rab Ra Rb Y Ra R1 Rb R1 Rb R2 Rb R1 R1 R2 R R 3 2 Ra Rc R1 Rc R2 ( R1 R3 ) Ra R1 R2 R3 Rb R3 Ra Rb REPLACE IN THE THIRD AND SOLVE FOR R1 R1 R2 R3 R2 R3 Rb R1 R2 R3 Ra Rb Rb Rc Rc Ra R3 ( R1 R2 ) R 1 Rb Rc Rb R R 3 1 R1 R2 R3 Rc R1 R2 R3 R R Rb Rc Rc Ra R2 a b Rc Y R1 ( R2 R3 ) Rc Ra R R Rb Rc Rc Ra R1 R2 R3 R3 a b Ra SUBTRACT THE FIRST TWO THEN ADD TO THE THIRD TO GET Ra Y POWER FACTOR CORRECTION Similar to single phase case. Use capacitors to increase the power factor Balanced load Low pf lagging Keep clear about total/phase power, line/phase voltages Q Qnew Qold Reactive Power to be added To use capacitors this value should be negative pf pf cos f sin f 1 pf 2 tan f 2 1 pf Q P tan f lagging Q 0 LEARNING EXAMPLE f 60 Hz, | Vline | 34.5kV rms . Required : pf 0.94 leading Pold 18.72 MW S P jQ P | S | cos f Q | S | sin f pf cos f Qnew 6.8 MVA pf new 0.94 leading Q 6.8 15.02 21.82 MVA Qper capacitor 7.273MVA Q P tan f tan f pf 1 pf lagging Qold 0 2 pf cos f sin f 1 pf 2 0.626 | Qold | 15.02 MVA Pold 18.72 MW Y connection Vcapacitor 34.5 kV rms 3 34.5 103 6 7.273 10 2 60 C 3 C 48.6 F 2 LEARNING BY DESIGN Proposed new store #4ACSR wire rated at 170 A rms S1 70036.9 S2 100060kVA S3 80025.8kVA 560 j 420 kVA 500 j866 kVA 720 j 349 kVA Stotal 1780 j1635 kVA 241742.57 kVA | Stotal | 2.417 106 | I line | 101.1A rms 3 3 Vline 3 13.8 10 Wire is OK Pold Qnew P tan f ( new ) 758.28kVA pf new Q Qnew Qold 876.72kVA |Q per capacitor | CV 2 876.72 10 / 3 C 2 60 13.8 10 / 3 3 3 2 12.2 F