* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Using Low Voltage MicroGrids in Emergency Conditions
Voltage optimisation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Distributed control system wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Grid energy storage wikipedia , lookup
Control system wikipedia , lookup
Utility frequency wikipedia , lookup
Electrification wikipedia , lookup
Electrical grid wikipedia , lookup
Alternating current wikipedia , lookup
Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup
Mains electricity wikipedia , lookup
Power inverter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Resilient control systems wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power engineering wikipedia , lookup
September 10th, 2009 Campus da FEUP Rua Dr. Roberto Frias, 378 4200 - 465 Porto Portugal Decentralised Energy Systems in Developing Countries T +351 222 094 000 F +351 222 094 050 [email protected] J. A. Peças Lopes © 2009 Electrical Systems in Developing Countries • Small isolated electrical grids fed by small power stations frequently with small Diesel units are frequent. – These grids correspond often to a small geographical area where a population nucleus is located. – Large distances among the load centres makes unfeasible the development of interconnected electrical grids. – Reliability is week and electricity is present only a few hours per day. A change is required to improve quality of life © 2006 2 Selecting Renewable Generation Technologies • The selection of the renewable energy technologies to be used for generating electricity in remote areas can be made using GIS: – Availability of the resources – Costs of installation – Costs of transportation © 2006 3 Developing Countries: New paradigms are under development Breaking the Rules Yesterday Central power station Tomorrow: distributed/ on-site generation with fully integrated network management Photovoltaics power plant Tra n s m is s io n Ne tw o rk Storage Storage Flow Control Storage Storage House Dis trib u tio n Ne tw o rk Local CHP plant Power quality device Wind power plant Factory © 2006 Power quality device House with domestic CHP Commercial building 4 Developing Countries: New paradigms are under development • The change of paradigm that DG introduced started at HV and MV level DG units have been operated without any control, injecting active and reactive power in the grid. © 2006 5 DG Technologies • Distributed Generation (DG) has attained a considerable penetration level in HV and MV networks, involving different types of sources and conversion technologies; – The most relevant ones are: • Mini-hydro using synchronous or asynchronous generators; • Cogeneration using mainly synchronous units; • Biomass generation units with synchronous generators; • Wind generation, using conventional asynchronous or DFIM units and synchronous machines with electronic converters. – Usually these generation devices do not participate in voltage control and frequency regulation © 2006 6 DG Technologies • Microgeneration directly connected to the LV network is becoming a reality: – Next 10 years: • The change that occurred in MV networks will also happen in LV networks: – Connection of small modular generation sources; – Typically in the range from 5 to 100 kW; – Fuel cells, renewable generation (wind turbines and PV systems), micro turbines (natural gas or bio fuels), micro-CHP; • LV networks are also becoming active; © 2006 7 MicroGrid: A Flexible Cell of the Electric Power System MG Hierarchical Control: • MGCC, LC, MC • Communication infrastructure PV MC LC MC Microturbine LV LC MV Wind Gen LC MC LC MC MGCC Storage Device MC LC Fuel Cell © 2006 8 Microgeneration technologies: Micro-wind turbines © 2006 9 Microgeneration - Solar Photovoltaic (PV) 1/Ropt I M ISC N A Imax P 1/R O © 2006 Vmax S VOC V 10 Energy storage – flywheels or batteries © 2006 11 Dynamic Modelling of Components – Inverters • Inverter Control Modes – PQ control • Designed for grid-connected operation • The inverter is controlled to meet an active and reactive power set-point © 2006 12 Dynamic Modelling of Components – Inverters • Inverter Control Modes – Voltage Source Inverter Control - VSI • Designed for standalone operation (however, in some cases, grid-connected operation is also possible) • The inverter “feeds” the load with pre-defined values for voltage and frequency w w0 k P P V V0 kQ Q w01 wgrid k P P1 V01 Vgrid kQ Q1 © 2006 13 MicroGrid Operation and Control • Control Modes for MG Islanded Operation – Energy storage is required to balance local load and generation in the moments subsequent to transients (disconnection of the MV network or load following during islanding operation) aiming voltage and frequency control. – Combining Inverter Control Modes, two control strategies are possible: • Single Master Operation • Multi Master Operation © 2006 14 MicroGrid Operation and Control • Storage device’s active power output is proportional to the MG frequency deviation (droop control) DP DPmax Correct permanent frequency deviations during islanding operation Dfmin Dfmax Df=f0-f DPmin f ref = 50 Hz S PI MC Microsource f MG © 2006 15 MicroGrids Dynamic Simulation – Test System 20 kV 0.4 kV MG Main Storage 30 kW SSMT Group of 4 Residences 10 kW PV Appartment building 2x30 kW SSMT Industrial Load 15 kW wind generator Appartment building 30 kW SOFC 10 kW PV © 2006 16 Results from Simulations • MG Frequency and VSI Active Power 50.2 Load shedding Frequency (Hz) 50 49.8 49.6 Load reconnection 49.4 49.2 0 50 100 50 100 150 200 250 150 200 250 VSI Active Power (kW) 50 40 30 20 10 0 -10 -20 0 Time (s) © 2006 17 Using MicroGrids for Service Restoration • DG maturation can offer ancillary services, such as the provision of Black Start in low voltage grids • Black-Start is a sequence of events controlled by a set of rules – A set of rules and conditions are identified in advance and embedded in MGCC software – These rules and conditions define a sequence of control actions to be carried out during the restoration stages Increased reliability © 2006 18 Growing the system With microgrids and DG • Increase reliability to end user consumers increase consumption levels (lighting, refrigerators, TV set, …) • Interconnect nearby systems and define common operating strategies that improve economics and global reliability • Introduce more renewable power sources © 2006 19 Integrating Wind Power and other intermittent power sources • A reliable integration of intermittent power sources in na islanded system requires: – Advanced management and control systems to minimize operation costs and assure security of operation; – Exploitation of storage facilities, involving specific management and control strategies. © 2006 20 Conclusions • Extend and adapt the concepts of distributed generation and microgeneration pursued lately in developed countries to the existing reality of developing countries • Increase renewable power sources presence – Reliability improvements; – Reduce economic costs – Increases quality of life and economic development in local populations – Avoids CO2 emissions © 2006 21