Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
TrueSTEAM™ Humidification Systems Module 3: Basic Installation Module 3 – Basic Installation • Definition of a basic Installation • What’s included in the TrueSTEAM™ box • Step by step Installation Instructions • Cautionary measures for avoiding common installation mistakes • What homeowners can expect after a TrueSTEAM™ installation What’s Included in the TrueSTEAM Box? Tools and Parts Needed • Tools needed to install TrueSTEAM™ - Wire cutter/stripper - Torx driver T-20 and T-30 - Standard screwdriver - 1-3/4-in. diameter hole saw - 1/8-in. drill bit - 18-gauge wire (up to 5 conductor) • Other Optional Parts: - Condensate pump rating of 212°F (100°C) if used. - Drip pan with water sensor shut-off required underneath TrueSTEAM if installed in or above finished space. Tips and Precautions • Be sure to read and understand the Installation Guide and complete list of precautions before starting work! - Adhere to voltage, heavy equipment and hot water warnings in the manual - Comply to all install, plumbing, wiring guidelines in the manual, as well as those listed in your local guidelines - Wear safety glasses • Do not install in locations which are: - Outside operating temperature range: 34°F to 104°F - In confined space (less than 1 foot of clearance) - Exposed to outside weather DEDICATED TRUESTEAM HOTLINE 800-814-9452 Step 1: Choosing a Location Choose a location that has access to a: • • • • Vertical surface with adequate clearances. Cold water supply line must be used. Drain with a high-temperature water rating. Electrical circuit rated to your humidifier. Model HM506 HM509 HM512 Required Minimum Circuit Capacity 7 Amps 10 Amps 12 Amps Step 2: Mounting on the Supply Duct • Position template on supply duct, and ensure proper clearances from A-coil. Step 3: Mount Bracket • Secure bracket to duct using provided self-drilling sheet metal screws. Step 4: Insert Duct Nozzle • Install duct nozzle by ensuring o-ring gasket is properly seated in the groove, and slide foam gasket down over nozzle. • Insert nozzle and twist clockwise to ensure tight seal of nozzle to TrueSTEAM. Step 5: Mounting TrueSTEAM • Push down to secure humidifier to bracket arms. • Ensure gasket forms tight seal in duct hole. • Allow 4 inches clearance from nozzle outlet to any duct wall and allow 24 inches of downstream open duct air space to prevent duct condensation. Step 6: Plumbing Use only cold water. Do not use hot water supply. a. Water Filter. Insert 1/4-inch copper or plastic water line. Apply modest pull to ensure a tight fit. b. Back-flow preventer valve. Insert 1/4-in. copper or plastic water line. Apply modest pull to ensure a tight fit. c. Connect 1/2-in. drain tube. Secure drain tube to barbed fitting with hose clamp. d. Shut off the water supply. Secure 1/4-in. copper or plastic water feed tube. Step 6: Plumbing After Installation • Educate the homeowner on what to expect next. • It may take up to a week of continuous operation to achieve the humidity control set point. • A slight plastic smell may be detectable the first week of operation. This is normal and will dissipate after running a short time. • There may be a slight increase in the homeowner’s energy bill even when TrueSTEAM™ is sized and operating correctly. Set the expectation that comfort costs money to avoid callbacks. Support Materials • Additional Materials on TrueSTEAM Installation are available. • Visit www.forwardthinking.honeywell.com - Click on Humidification • Enter literature form: #69-2285: TrueSTEAM Installation Manual Module 3 – Basic Installation • Definition of a basic Installation • What’s included in the TrueSTEAM box • Step by step Installation Instructions • Cautionary measures for avoiding common installation mistakes • What homeowners can expect after a TrueSTEAM™ installation.