* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SECTION 263533 LOW-VOLTAGE POWER FACTOR
Standby power wikipedia , lookup
Utility frequency wikipedia , lookup
Power inverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Wireless power transfer wikipedia , lookup
Audio power wikipedia , lookup
Electrical substation wikipedia , lookup
Power over Ethernet wikipedia , lookup
Buck converter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Electrification wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electric power system wikipedia , lookup
Rectiverter wikipedia , lookup
Power factor wikipedia , lookup
Power engineering wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
SECTION 263533 LOW-VOLTAGE POWER FACTOR CORRECTION CAPACITORS PART 1 – GENERAL 1.01 A. 1.02 A. 1.03 RELATED DOCUMENTS Division-26 Basic Electrical Materials and Methods sections apply to the work of this section. SUMMARY Section provides for low-voltage (600V or less) power factor correction capacitor systems: 1. Fixed Power Factor Correction Capacitor Systems (with or without Reactors) 2. Automatic Power Factor Correction Capacitor Systems (with or without Reactors) REFERENCE STANDARDS A. ANSI/IEEE 18 – Standard for Shunt Power Capacitors; 2013 B. NEMA CP 1 – Shunt Capacitors; National Electrical Manufacturers Association; 2000 (R2008) C. UL 810 – Capacitors; Current Edition, Including All Revisions D. NEC Compliance – Comply with NEC as applicable to location and installation of power factor correction capacitor systems and associated equipment 1.04 COORDINATION A. Coordinate the work with other trades to avoid placement of ductwork, piping, equipment, or other potential obstructions within the dedicated equipment spaces and working clearances required by NFPA 70. B. Coordinate arrangement of electrical equipment with the dimensions and clearance requirements of the actual equipment to be installed. C. Coordinate the work with placement of supports, anchors, etc. required for mounting. D. Capacitors for Installation Within Motor Control Centers (MCCs): Coordinate work to provide capacitors suitable for installation in equipment to be provided. 4/30/2017 Myron Zucker, Inc. Page 1 Low-Voltage Power Factor Correction Capacitors E. 1.05 Notify Architect of any conflicts with or deviations from the contract documents. Obtain direction before proceeding with work. SUBMITTALS A. Product Data: Provide manufacturer’s standard catalog pages and data sheets for capacitor assemblies, including ratings, configurations, materials, fabrication details, dimensions, finishes, weights, and service condition requirements. B. Motor Overload Protective Device Calculations: Where capacitors are to be connected on the load side of motor overload protective devices (when permitted), indicate overload device ratings adjusted for reduced current. C. Specimen Warranty: Submit a sample of manufacturer’s warranty. D. Manufacturer’s Installation Instructions E. Operation and Maintenance Data 1.06 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with a minimum three years documented experience. B. Installer Qualifications: Company specializing in performing the work of this section with a minimum of five years documented experience with power factor correction systems of similar size, type, and capacity. C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. D. Comply with IEEE 18 and NEMA CP 1. E. Comply with NFPA 70. 1.07 WARRANTY A. Capacitor Systems: Provide minimum two year manufacturer warranty covering repair or replacement due to defective materials or workmanship. B. Capacitor Cells: Provide minimum two year manufacturer warranty covering repair or replacement due to defective materials or workmanship. 4/30/2017 Myron Zucker, Inc. Page 2 Low-Voltage Power Factor Correction Capacitors 1.08 A. DELIVERY, STORAGE AND HANDLING Pack and crate capacitor systems as required to permit ease of handling and to provide protection from damage during shipping, handling and storage. PART 2 – PRODUCTS 2.01 A. 2.02 MANUFACTURERS Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Fixed Power Factor Correction Capacitor Systems (with or without Reactors): a. Myron Zucker, Inc. b. Or Approved Equal 2. Automatic Power Factor Correction Capacitor Systems (with or without Reactors): a. Myron Zucker, Inc. b. Or Approved Equal GENERAL – CAPACITORS A. UL and cUL listed or recognized. B. Capacitor Cell Construction: Self-healing, metalized polypropylene film; dry (resinencapsulated) or liquid-impregnated with non-PCB, non-toxic, biodegradable dielectric fluid; provide three-phase cells (configurations utilizing factory-wide single phase capacitors are not acceptable). Each cell shall be hermetically sealed in a tin-plated steel container. C. Cell Rupture Protection: UL listed pressure-actuated circuit interrupter shall disconnect all three phases at the same time to maintain a balanced circuit and prevent capacitor cell case rupture. D. Discharge Resistors: Factory installed and wired three-phase delta connected external discharge resistor network. The resistors shall be sized to reduce residual voltage to less than 50 volts within one minute of de-energization. E. Operating Conditions: 1. Ambient Operating Temperatures: Between -40°C and 46°C (-40°F and 115°F) 2. Maximum Altitude: 1800 meters (6000 feet) 3. Humidity: 0 to 95 percent, non-condensing F. Losses: Not greater than 0.5 W per kVAr. 4/30/2017 Myron Zucker, Inc. Page 3 Low-Voltage Power Factor Correction Capacitors G. Capacitor cell shall be designed for a 20-year life continuous duty. H. Individual capacitor cells shall be covered by a two-year warranty. 2.03 FIXED POWER FACTOR CORRECTION CAPACITOR SYSTEMS A. Manufactured systems consist of capacitor cells, enclosures, and associated components specifically designed for three-phase power factor correction applications. Comply with IEEE and NEMA CP 1, and list and label as complying with UL 508A or UL 810 as applicable. Factory wired, ready for field connection to external circuits at a single set of terminals. Capacitor system shall not contain any fillers (such as Vermiculite) so that all capacitor cells can be accessed for visual inspection. B. Provide complete power factor correction capacitor system consisting of all required equipment, conduit, boxes, wiring, supports, accessories, system programming, etc., as necessary for a complete operating system that provides power factor correction as indicated. C. Description: Capacitor systems that supply a fixed amount of reactive power (kVAr). 1. At-the-load fixed power factor correction: a. Motors larger than ____ HP 1) Voltage/frequency as indicated on drawings 2) Capacitance: Size kVAr per motor manufacturer’s recommendations b. Alarm indications: 1) Loss-of-capacitance and blown fuse indication visible from exterior (Calmount® KIM Model) 2) Blown fuse indication visible from exterior (Calmount® KNM Model) 2. At-the-load fixed power factor correction with Reactors – for use in harmonicrich environments: a. System shall include tuning reactors. b. Reactors shall be sized to the ____ harmonic (____Hz) tuning point. c. Variable Frequency Drives (VFD) Larger Than ____ HP. 1) Voltage/frequency as indicated on drawings 2) Capacitance: Size kVAr per VFD/motor manufacturer’s recommendations d. Alarm indications: 1) Loss-of-capacitance, phase imbalance, overcurrent/undercurrent, blown fuse indication, reset and self-diagnostic function 3. Service entrance, distribution center or branch panel fixed power factor correction: a. Total System Power Factor: Achieve corrected total system power factor of ___. 1) Voltage/frequency as indicated on drawings 2) Capacitance: ____ kVAr (Caltrap® RIM Model) 4/30/2017 Myron Zucker, Inc. Page 4 Low-Voltage Power Factor Correction Capacitors b. Alarm indications: 1) Loss-of-capacitance, phase imbalance, overcurrent/undercurrent, blown fuse indication, reset and self-diagnostic function (Capacibank® CIM Model) 2) Blown fuse indication visible from exterior (Capacibank® CNM Model) 4. Service entrance, distribution center or branch panel fixed power factor correction with Reactors – for use in harmonic-rich environments: a. Total System Power Factor: Achieve corrected total system power factor of ___. 1) Voltage/frequency as indicated on drawings 2) Capacitance: ____ kVAr b. System shall include tuning reactors. c. Reactors shall be sized to the ____ harmonic (____Hz) tuning point. d. Alarm indications: 1) Loss-of-capacitance, phase imbalance, overcurrent/undercurrent, blown fuse indication, reset and self-diagnostic function 5. Capacitors for installation within Motor Control Centers (MCCs): a. Suitable for installation in equipment to be provided in accordance with Motor Control Center Manufacturer Specification Section. 1) Voltage/frequency as indicated on drawings 2) Capacitance: _____kVAr b. Rockwell Allen-Bradley MCC bucket/compartment design 1) Blown fuse indication lights provided (Capacitrap® CIM Model) (Traymount® TANM Model) 2) c. No indication lights provided (Traymount® TAPM Model) Eaton Cutler-Hammer MCC bucket/compartment design 1) Blown fuse indication lights provided (Traymount® TWNM Model) 2) d. No indication lights provided (Traymount® TWPM Model) Siemens MCC bucket/compartment design 1) Blown fuse indication lights provided (Traymount® TFNM Model) 2) e. No indication lights provided (Traymount® TFPM Model) Schneider Square-D MCC bucket/compartment design 1) Blown fuse indication lights provided (Traymount® TSNM Model) 2) f. No indication lights provided (Traymount® TSPM Model) Other MCC bucket/compartment design 1) Blown fuse indication lights provided (Traymount® TUNM Model) 2) 4/30/2017 Myron Zucker, Inc. No indication lights provided Page 5 Low-Voltage Power Factor Correction Capacitors (Traymount® TUPM Model) D. Fuses: 1. Current-limiting, fast-acting with 200,000 ampere interrupting capacity. 2. Provide industry standard brand fuses that are completely accessible and replaceable. Inaccessible fuse links are not acceptable. 3. Provide fusing for all three phases. Two-line fusing is not acceptable. E. Short Circuit Current Rating: Provide capacitor systems with listed short circuit current rating not less than the available fault current at the installed locations as indicated on the drawings. F. Contactors: Suitable for high inrush currents associated with capacitor switching. Comply with UL rated A-191 and IEC rated 158-1. G. Enclosures: 1. Provide steel enclosures with ground lug and without knockouts. 2. Enclosures for capacitors used on individual motors will be designed for bottom or back conduit entry. 3. Environment Type per NEMA 250: Unless otherwise indicated, as specified for the following installation locations: a. Indoor Clean, Dry Locations: Type 1 or Type 12. b. Outdoor Locations: Type 3R or Type 4. 4. Hinged Doors: Pad lockable. 5. Provide removable lifting eyes for free-standing enclosure types; provide built-in mounting brackets for wall or shelf-mounting enclosure types. 6. Finish: Manufacturer’s standard unless otherwise indicated. H. Capacitor systems with Reactors: 1. Three-phase iron core reactors tuning in series with harmonic-duty capacitor cells. 2. Furnish Class H (180°C), 600 Volt insulation. 3. Hi-pot testing required on all reactors. 4. System tuning: Tuned below the 5th harmonic unless otherwise indicated, as required. 5. Furnish reactors with an integral thermistor. I. Options: 1. Integral circuit breaker or disconnect where indicated or required 2. Capacitor system may be expandable to accommodate future capacitance and / or reactors 3. Integral surge protective device 2.04 A. AUTOMATIC POWER FACTOR CORRECTION CAPACITOR SYSTEMS Manufactured systems consist of capacitor cells, enclosures, and associated components specifically designed for three-phase power factor correction 4/30/2017 Myron Zucker, Inc. Page 6 Low-Voltage Power Factor Correction Capacitors applications. Comply with IEEE and NEMA CP 1, and list and label as complying with UL 508A or UL 810 as applicable. Factory wired, ready for field connection to external circuits at a single set of terminals. Capacitor system shall not contain any fillers (such as Vermiculite) so that all capacitor cells can be accessed for visual inspection. B. Provide complete power factor correction capacitor system consisting of all required equipment, conduit, boxes, wiring, supports, accessories, system programming, etc., as necessary for a complete operating system that provides power factor correction as indicated. C. Description: Automatic Capacitor systems that supply a variable amount of reactive power (kVAr) in discrete kVAr steps by switching capacitor cell groups using contactors and microprocessor-based controllers as required to maintain a target power factor. 1. Service entrance automatic power factor correction system: a. Total System Power Factor: Achieve corrected total system power factor of ___. 1) Voltage/frequency as indicated on drawings 2) Capacitance: ____ kVAr 3) Steps: Not great than _____kVAr each b. VAR Controller features: 1) HMI key pad with back lit LCD display indicating all relevant PQ parameters 2) Quick CT programming function with automatic CT orientation recognition 3) Balanced used of steps and step count recording 4) Capacitor overload protection and step failure indication 5) 10 standard system alarms with 11 optional additional alarms 6) Internal panel temperature sensor for over temperature 7) Communication interfaces of various protocols (OPTIONAL) (Autocapacibank™ ACIM Model) 2. c. Provide integral circuit breaker/disconnect (OPTIONAL) Service entrance automatic power factor correction system with Reactors – for use in harmonic-rich environments: a. Total System Power Factor: Achieve corrected total system power factor of ___. 1) Voltage/frequency as indicated on drawings 2) Capacitance: ____ kVAr 3) Steps: Not great than _____kVAr each b. System shall be tuned to the ____ harmonic (____Hz). c. VAR Controller features: 1) HMI key pad with back lit LCD display indicating all relevant PQ parameters 2) Quick CT programming function with automatic CT orientation recognition 3) Balanced used of steps and step count recording 4) Capacitor overload protection and step failure indication 4/30/2017 Myron Zucker, Inc. Page 7 Low-Voltage Power Factor Correction Capacitors 5) 6) 7) d. 10 standard system alarms with 11 optional additional alarms Internal panel temperature sensor for over temperature Communication interfaces of various protocols (OPTIONAL) (Autocapacitrap™ ACIM Model) Provide integral circuit breaker/disconnect (OPTIONAL) D. Performance requirements: Controller permits selection of target power factor, adjustable to any value between 0.80 lagging and unity. Controller continuously monitors the power factor on circuits being corrected. Contactors open or close as required to bring the corrected circuit power factor closer to the target setting. E. Fuses: 1. Current-limiting, fast-acting with 200,000 ampere interrupting capacity. 2. Provide industry standard brand fuses that are completely accessible and replaceable. Inaccessible fuse links are not acceptable. 3. Provide fusing for all three phases. Two-line fusing is not acceptable. F. Short Circuit Current Rating: Provide capacitor systems with listed short circuit current rating not less than the available fault current at the installed locations as indicated on the drawings. G. Contactors: Suitable for high inrush currents associated with capacitor switching. Comply with UL508 and IEC60947-4-1. H. Enclosures: 1. Provide steel enclosures with ground lug and without knockouts. 2. Environment Type per NEMA 250: Unless otherwise indicated, as specified for the following installation locations: 3. Indoor Clean, Dry Locations: Type 1 or Type 12. 4. Outdoor Locations: Type 3R or Type 4. 5. Hinged Doors: Lockable, with all locks keyed alike. 6. Provide lifting eyes for free-standing enclosure types; provide built-in mounting brackets for wall or shelf-mounting enclosure types. 7. Finish: Manufacturer’s standard unless otherwise indicated. I. Capacitor systems with Reactors: 1. Furnished with three-phase iron core reactors and harmonic-duty capacitor cells, specifically designed for power factor correction in harmonic environments. 2. Furnish Class H (180°C), 600 Volt insulation. 3. Hi-pot testing required on all reactors. 4. System tuning: Tuned below the 5th harmonic unless otherwise indicated. 5. Furnish reactors with an integral thermistor wired to a relay for an overtemperature light indication. J. Provide current transformers (CTs) with appropriate ratio, type and configuration as required for system measurement. 4/30/2017 Myron Zucker, Inc. Page 8 Low-Voltage Power Factor Correction Capacitors K. VAR 1. 2. 3. 4. 5. 6. Controller: Solid-state, microprocessor-based controls, including the following: Built-in power factor meter. Manual and automatic modes. Step and power factor display. Adjustable target power factor with range of 0.80 inductive to unity. Adjustable step time delay. ______________________. L. Status Indications: 1. Power factor. 2. Voltage. 3. Current. 4. Real power (kW). 5. Reactive power (kVAr). 6. Apparent power (kVA). 7. Frequency. 8. Number of energized steps. 9. Step reconnection delay. 10. Voltage total harmonic distortion. 11. _______________________. M. Alarm indications: 1. Blown fuse, visible from exterior of enclosure. 2. Over compensation. 3. Under compensation. 4. Overcurrent. 5. Undercurrent. 6. Undervoltage. 7. Overvoltage. 8. Capacitor overload. 9. No voltage release. 10. Step failure. 11. High voltage total harmonic distortion (THD) (OPTIONAL). 12. ________________________. N. All output contacts shall be disabled within 8 milliseconds of main power interruption. The controller shall retain its programming after the restoration of supply voltage. The controller shall bring the capacitor bank back on line in a step, phased, normal sequence. O. Options: 1. Integral circuit breaker or disconnect where indicated or required 2. Capacitor system may be expandable to accommodate future capacitance and / or reactors 3. Integral surge protective device 4. Remote monitoring capability via PC 4/30/2017 Myron Zucker, Inc. Page 9 Low-Voltage Power Factor Correction Capacitors 2.05 A. SOURCE QUALITY CONTROL Factory test power factor correction equipment before shipment. Comply with NEMA CP 1. Include the following production tests on each system: 1. Short-time overvoltage test 2. Capacitance test 3. Loss determination test 4. Discharge resistor test 5. Leak test 6. Functional test of all operations, controls, indicators, sensors, and protective devices PART 3 – EXECUTION 3.01 INSTALLATION A. Install capacitor systems in accordance with manufacturer’s written instructions. B. Provide required supports, mounting pads, and attachments. C. Arrange equipment to provide minimum clearances and required maintenance access. D. Capacitor Connections at Individual Motors: 1. Unless otherwise indicated, connect capacitors to only be in service when motor is energized. Provide additional contactors as required. 2. Unless otherwise indicated or required, connect capacitors on the load side of motor starter contacts and on the line side of motor overload protective devices. a. Exceptions where capacitor is to be connected on line side of motor starter/controller include, but are not limited to: 1) Reversing motors 2) Multi-speed motors 3) Plugging 4) Jogging/inching 5) Soft-start starters 6) Variable frequency drives b. If the circuit is not accessible between the starter contacts and motor overload protective devices, capacitor may be connected on the load side of overloads provided that overloads are resized for reduced current. c. Submit wiring diagrams of proposed capacitor connections for approval prior to starting work. E. Automatic Capacitor Systems: 1. Locate current transformers (CTs) on line side of capacitor connection so that measurements include power factor correction. 2. Power factor controller will be pre-programmed to maintain desired power factor 4/30/2017 Myron Zucker, Inc. Page 10 Low-Voltage Power Factor Correction Capacitors F. 3.02 Remove capacitor fuses prior to bumping motors for testing purposes to prevent blowing fuses caused by energizing capacitor that has not yet discharged. FIELD QUALITY CONTROL A. Perform tests and inspections: Test system functions, operations, and protective features according to manufacturer’s written instructions. B. Prepare and start system in accordance with manufacturer’s instructions. 3.03 A. 3.04 A. STARTUP SERVICE Optional: Supervision of energizing power factor correction capacitor systems as well as performance tests as determined by the manufacturer shall be performed. DEMONSTRATION Training: Train Owner’s personnel on operation, adjustment, and maintenance of automatic capacitor systems. 1. Use operation and maintenance manual as training reference, supplemented with additional training materials as required. 2. Provide minimum two hours of training. 3. Instructor: Manufacturer’s authorized representative. 4. Location: At project site. END OF SECTION 263533 4/30/2017 Myron Zucker, Inc. Page 11 Low-Voltage Power Factor Correction Capacitors