Download from 1 to 6 kVA

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

History of electric power transmission wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Power engineering wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electric battery wikipedia , lookup

Islanding wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Rectifier wikipedia , lookup

Voltage optimisation wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Alternating current wikipedia , lookup

Two-port network wikipedia , lookup

Mains electricity wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Rechargeable battery wikipedia , lookup

Buck converter wikipedia , lookup

Metadyne wikipedia , lookup

Switched-mode power supply wikipedia , lookup

AC adapter wikipedia , lookup

Opto-isolator wikipedia , lookup

Liquid-crystal display wikipedia , lookup

Uninterruptible power supply wikipedia , lookup

Transcript
Networks & critical applications
from 1 to 6 kVA
E4 LCD LT range is a reliable and cost-effective solution dedicated to critical
networks, datacenters, server groups and industrial applications.
• Top-of-the-range protection
The E4 LCD LT range, fitted with micro-processor controlled On-Line Double Conversion technology, delivers a perfect
sinusoidal output current and provides thorough and effective protection of critical devices.
The power factor is optimized, reaching 0.8 on 1 to 5 kVA models and 0.7 on 6kVA models, thereby offering higher
performance and good efficiency for vital applications.
On-Line Double Conversion
Technology
1/
1
LCD
3/
1
Tel/fax/modem/networks
protection *
1/
1
+
LCD
LCD control panel
PURE POWER
• Tailored backup time at a competitive price
This is an ideal range to avoid over-sizing your electrical protection. The number of batteries is limited and the E4
LCD LT range insures a backup time from 3 to 6 minutes at 75% load. There is no extended backup time available.
• Smart functions
• The ECO mode function offers energy cost savings
• Cold start function : it enables an emergency situation involving a total power cut to be overcome by
starting the UPS using batteries without the main power supply.
Remote control
software
• Practical design
UPS status is seen at a glance on an intuitive LCD screen. The UPS is controlled by
a simple control panel on the front: ON/OFF, operating mode configuration, etc.
• Communication
The RS 232 communication port enables the UPS to communicate with the various
stations and IT servers that it is protecting.
INFOSEC_Fiche_E4LCDLT_UK-V05.indd 1
Up to 6 minutes
of backup time
* See models concerned
11/10/11 09:39
3/
1
-
1 to 6 kVA
1/
Power input
2/
IEC protected outlets.
3/
Input fuse
4/
RS-232 port
5/
RJ45 connectors
6/
Input terminal
7/
Output terminal
8/
Output fuse
4
4
4
4
8
2
2
1
3
6
E4 LCD LT 1K
1000 VA
800 W
0,8
E4 LCD LT 2 K
E4 LCD LT 3 K
E4 LCD LT 2K
E4 LCD LT 3K
E4 LCD LT 5K
E4 LCD LT 6K
2000 VA
1600 W
0,8
On Line Double Conversion
3000 VA
2400 W
0,8
5000 VA
4000 W
0,8
6000 VA
4200 W
0,7
Technologie
7
1
E4 LCD LT 1 K
Facteur de puissance
2
3
1
Puissance
2
5
5
3
• Accessories
INPUT
Battery mode Transfer ( based
on load percentage 100% 80 % / 80 % - 70 % / 70 - 60
% / 60 % - 0)
Voltage
Range
Low Line Comeback
High Line Transfer
High Line Comeback
110 V
80VAC/70VAC/60VAC/50 VAC ± 5 %
-
230 V
160VAC /140VAC/120VAC/110VAC ± 5 %
175VAC /150VAC/130VAC/110VAC ± 5 %
110 V
230 V
110 V
230 V
110 V
230 V
85 VAC ± 5 %
170VAC ± 5 %
180 VAC ± 5%
150 VAC ± 5 %
300 VAC ± 5 %
280 VAC ± 5%
145 VAC ± 5 %
290 VAC ± 5 %
270 VAC ± 5 %
47 ~ 53 Hz or 57 ~ 63 Hz (Auto sensing)
Single phase with ground
≥ 0.98 (Normal input 220-230Vac @ full load condition)
Frequency Range
Phase
Power Factor
OUTPUT
Voltage
AC Voltage Regulation (Batt. Mode)
Frequency Range (Normal mode)
Frequency Range (Batt. Mode)
Current Crest Ratio
Harmonic Distortion
AC Mode to Batt. Mode
Inverter to Bypass
Waveform (Batt. Mode)
Backup Time (75% load)
Output outlets IEC
Terminal output
230 V (or 110 V for NEMA models)
≤ 4 % THD
(charge linéaire)
≤ 9 % THD
(Non-linear Load)
Crédits photos : Shutterstock - Ciaran Griffin ,Stockbyte - iStockphoto.
Maintenance By-pass external box (BPM) :
available from 1 to 3 kVA UPSs
≤ 4 % THD (Linear Load)
• InfoPower software
≤ 7 % THD (Non-linear Load)
3 mn
4
No
4 mn
4
No
Zero
4 ms (Typical)
Pure Sinewave
6 mn
6
Yes
86%
83%
88%
85%
90%
87%
90%
87%
12V / 7Ah
2
12V / 7Ah
4
12V / 10Ah
8
27.4 VDC ± 1%
54.7 VDC ±1%
12V / 7Ah
6
1.0 A
82.1 VDC ±1%
Transfer
Time
5 mn
6
Yes
6
Yes
EFFICIENCY
AC Mode
Battery Mode
BATTERY
Battery Type
Battery Numbers
Charging Current (max.)
Charging Voltage
109.2 VDC ±1%
INDICATORS
LCD Panel
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Low Battery
Overload
Fault
SNMP agent:
The use of the SNMP agent with E4 LCD LT UPS
devices makes it easier to manage the UPS and
network power supply due to a number of special
features:
• Connection to the Ethernet network and
identification by IP address
• Battery low detection.
• Configuring and programming system
extensions and restarts on a weekly or other
basis
• Setting the UPS locally or remotely.
• Auto-diagnosis of UPS devices while operating.
• Automatic shutdown according to pre-defined
priorities on network PCs.
• Sending warning messages to network users.
• Events log.
Isolation transformer :
Available on 6kVA model.
230 V
± 1%
47.5 ~ 52.5 Hz or 57.5 ~ 62.5Hz
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
3:1
≤ 3 % THD
(Linear Load)
≤ 6 % THD
(Non-linear Load)
E4 LCD LT 5 – 6 K
An E4 LCD UPS can
close files on its
own, if there is no
power, thanks to the
InfoPower control
software (supplied as standard), and in doing so
saves data from all the PCs in a network.
The communication software also offers a
graphical interface to view system status, different
measurements, events log, etc.
• Warranty
Two-year warranty (UPS
+ battery) with standard
replacement of the device or
on-site repair.
Sounding every 4 seconds
Sounding every second
Sounding twice every second
Continuously sounding
PHYSICAL
Dimension, H x W x D (mm)
Net Weight (kgs)
400 X 146 X 205
9,5
397X145X220
17,5
421 X 190 X 318
29
37
ENVIRONMENT
Operation Humidity
Noise Level
20-90 % RH @ 0- 40°C (non-condensing)
Less than 45dB @ 1 Meter
0-90 % RH @ 0- 45°C (non-condensing)
Less than 55dB @ 1 Meter
MANAGEMENT
Software
RS 232 Port
NORMES
Standard
EMC
Low voltage (safety)
CE RoHS
EN62040-2
EN62040-1
Infosec Communication
INFOS COMMERCIALES
Warranty
Gencods
3700085 67102 3
3700085 67103 0
2 Years
3700085 67104 7
3700085 67105 4
3700085 67106 1
©2011 Infosec Communication, all rights reserved. Infosec UPS System is an Infosec Communication registered trademark. All other trademarks trademarks belong to their respective owners.
Photos are not binding. Specifications are subject to change without prior notice. Backup time is only a guide: actual duration may vary depending on the temperature, battery condition and
number of peripherals connected. UPS devices belong to the electronic and electric hardware category. At the end of their useful life, they must to be disposed of separately. 09 11 02 55 111 20
INFOSEC_Fiche_E4LCDLT_UK-V05.indd 2