Download 7000 Series

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
DynaLock
SERIES 7000
KEYSWITCHES
705 Emmett Street Bristol, CT 06011-2728
Phone:(860)582-4761 Fax:(860)585-0338
INSTALLATION INSTRUCTIONS
ASSEMBLY PROCEDURE
To begin the installation select any standard 1-1/8” or 1-1/4” mortise cylinder. The keyswitch is designed to work with any
cam. The “bat” type cam (see reverse side) is recommended.
FIGURE A
1. Insert the Mortise Cylinder through the front of the Faceplate. Be sure to orient the cylinder keyway correctly.
2. Slide the Cylinder Spacer onto the end of the Mortise Cylinder, up to the back of the Faceplate.
3. Slide the Switch Mounting Bracket onto the end of the cylinder. The triangular tabs on the bracket must align with the
corresponding notches in the barrel of the cylinder. With the bracket installed its upper tab will rest against the back of
the Faceplate and center itself over the upper Faceplate mounting screw hole.
4. With all parts in proper alignment apply the supplied thread lock and install the Cylinder Locknut onto the end of the
Mortise Cylinder. Firmly tighten with pliers.
A
B
KEYSWITCH ASSEMBLY - EXPLODED VIEW
REARVIEW - ASSEMBLED KEYSWITCH
(SINGLE & DUAL SWITCH MODELS)
MORTISE CYLINDER
FACEPLATE (1-GANG)
CYLINDER SPACER
SWITCH
MOUNTING
BRACKET
LOCK
WASHER
HEX NUTS
SWITCH ASSEMBLY
(TYPICAL)
CYLINDER
LOCKNUT
MODELS:
7001
7002
7021
7022
MODELS:
7003
7023
7004
7024
7005
7025
FIGURE B
5. Mount the switch(es) supplied for your specific model to the Switch Mounting Bracket using the hardware furnished.
For models utilizing only one switch mount the switch in left side position (as viewed from the rear of the Keyswitch).
Do not use the center mounting hole.
6. Final switch adjustment will vary depending upon cylinder and cam type selected. Experiment with switch location
until cam makes reliable contact with the switch and fully depresses the plunger when activated.
Note: Mount the switch as high as reasonable within the bracket for maximum clearance between switch and
box botttom.
Page 1
7000 MANUAL - FORM 7000-001 03/04
7000 SERIES KEYSWITCH INSTALLATION INSTRUCTIONS
MORTISE CYLINDER CAMS
RECOMMENDED CAM SHAPES
For proper keyswitch operation DynaLock
recommends using one of the three commonly
available “bat” style mortise cylinder cams
shown.
Note: Images are approximately actual size.
ADAMS RITE
#MS
(OR EQUAL)
YALE
#1161
(OR EQUAL)
CORBIN/RUSSWIN
#A02
(OR EQUAL)
SWITCH INFORMATION
Note: All switch contacts are rated 6 Amps @ 125VAC
WIRING DETAILS
SWITCH
DESCRIPTION
SPDT
DPDT
MOMENTARY CONTACT:
Rotating the key to its stop changes the state
of the contact while the key is held in that
position. Rotating the key back to vertical
returns the switch contact to its original state.
Key is removeable in the vertical position.
MAINTAINED CONTACT:
Rotating the key from vertical to its stop and
back to vertical changes the state of the switch
contact. To return the contact to its original
state this procedure must be repeated. Key is
removeable in the vertical position.
BI-COLOR LED OPTION WIRING
The Bi-Color LED can display status in two colors - red or green and is pre-configured to operate on 24VDC.
For 12VDC operation remove the outer resistor from the black wire. The LED may be wired to operate as
follows:
Applying (+) VDC to RED wire and (-) to BLACK wire illuminates LED - RED
Applying (+) VDC to GREEN wire and (-) to BLACK wire illuminates LED - GREEN
RED
BI-COLOR
LED
Resistor
Resistor
( ) VDC - ILLUMINATES LED RED
BLACK ( )
COMMON
GREEN ( ) VDC - ILLUMINATES LED GREEN
Page 2
7000 MANUAL - FORM 7000-001 03/04