Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Prepared by: Approved by: Traceability Chart (TM) (TM Leader) Date: 20-Mar-09 Date: 20-Mar-09 Scope: Electrical Calibration (1) (Voltage, Current, Power) Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 National Institute of Metrology (Thailand), NIMT National Standard NEC's Highest Standards Working Standard Equipment: - DCV Standard Cell, Fluke 732B - Multi-function Calibrator, Fluke 5720A - Amplifier, Fluke 5725A - AC Measurement System, Fluke 5790A+WB - Digital Multimeter, Agilent 3458A (Opt-002) - Standard Resistor Set, Fluke 742A's - Standard Resistor Set, IET SRX's series - Metal Film Resistor Set, Fluke - AC Shunt Set, Fluke A40's - AC Shunt Guidline 7320 - Primary AC Shunt HOLT HCS-1 Functions / Ranges: - DCV 10V, 1.018V - DCV (0~1kV), DCA (0-2.2A), ACV (0-1kV, 10Hz-1MHz), ACA 0-2.2A (10Hz-10kHz) - ACV (300~1kV, 40Hz-100kHz), DCA (2.2-11A), ACA (2.2-11A, 10Hz-10kHz) - ACV (2mV~1kV, 10Hz-1MHz), AC-DC Diff (2mV-1kV, 10Hz-1MHz), ACV (Wide-Band, 50Ω, 2mV-7V, 10Hz-30MHz) - DCV (0~1kV), DCA (0-1A), ACV (0-0.7kV, 10Hz-10MHz), ACA (0-1A, 10Hz-100kHz) - DCA (0~200mA) - DCA (0A~20A) - ACA (AC/DC Diff, 3µA~10mA, 10Hz~100kHz) - ACA (AC/DC Diff, 10mA~5A, 10Hz~30kHz) - ACA (AC/DC Diff, 5A~10A, 10Hz~30kHz) - ACA (AC/DC Diff, 10A~50A, 10Hz~30kHz) NEC's Working Standards Working Standard Equipment: - DCV Standard Cell, Fluke 732B - Multi-function Calibrator, Fluke 5700A - Multi-product Calibrator, Fluke 5520A - Multi-product Calibrator, Fluke 5500A - DC V/A Standard, Yokogawa 2560 - AC V/A Standard, Yokogawa 2558 - Calibrator & Source, Keithley 263 - Multi-function Transfer Standard, Wavetek 4950 - Digital Multimeter, HP 3458A (Opt-002) - Digital Multimeter, Fluke 8846A - Digital Multimeter, Agilent 34411A, 34401A - Electrometer, Keithley 617 - Metal Film Resistor Set, Fluke - AC/DC Shunt, Wavetek 4953 - Metal Clad Resistor Set, PCN - Standard Resistor Set, Yokogawa 27X2's - Standard Shunt, Yokogawa 2743 - Standard Resistor, Advantest TR's series - DC Power Supply, Kikusui PAK10-100 - Electronic Load, Kikusui PLZ's series - AC/DCA Cut-off Meter, Kiksui TOS-1200 Functions / Ranges: - DCV 10V, 1.018V - DCV (0~1kV), DCA (0~2.2A), ACV (Up~1kV, 10Hz~1MHz), ACA (Up~2.2A, 10Hz~10kHz) - DCV (0~1kV), DCA (0~20A), ACV (Up~1kV, 10Hz~500kHz), ACA (Up~20A, 10Hz~30kHz) - DCV (0~1kV), DCA (0~10A), ACV (Up~1kV, 10Hz~500kHz), ACA (Up~10A, 10Hz~10kHz) - DCV (0~1kV), DCA (0~30A) - ACV (Up~1kV, 40Hz~400Hz), ACA (Up~50A, 40Hz~400Hz) - DCV (0~20V), DCA (0~20mA) - DCV (0~1kV), DCA (0~1A), ACV (Up~1kV, 10Hz~1MHz), ACA (Up~1A, 10Hz~30kHz) - DCV (0~1kV), DCA (0~1A), ACV (Up~0.7kV, 10Hz~10MHz), ACA (Up~1A, 10Hz~100kHz) - DCV (0~1kV), DCA (0~10A), ACV (Up~1kV, 10Hz~500kHz), ACA (Up~10A, 10Hz~30kHz) - DCV (0~1kV), DCA (0~3A), ACV (Up~0.7kV, 10Hz~500kHz), ACA (Up~3A, 10Hz~30kHz) - DCV (0~200V), DCA (0~20mA) - ACA (AC/DC Diff, 3µA~10mA, 10Hz~100kHz) - ACA (AC/DC Diff, 10mA~10A, 10Hz~100kHz) - DC/ACA (0~200A, DC~60Hz) - DCA (0~20A) - DCA (20~100A) - DCA (10pA~10nA) - DCA (0~100A) - DCV (0~500V), DCA (0~140A), DCW (0~1000W) - DC/ACA Cut-Off (0~100mA, DC~60Hz) Customer's Equipment Voltage/Current Meters (Analog/Digital): - * DCV Meters (0~1kV) - * ACV Meters (Up~1kV, 10Hz~30MHz) - * DCA Meters (0~100A) - * DCA Clamp Meter (0~1kA) - * ACA Meters (Up~50A, 10Hz~100kHz) - * ACA Clamp Meter (Up~1kA, 45~440Hz - * Digital Electrometer (1pA~20mA, 0~1kV) - * DC/AC Cut-off Current Meter (0~100mA, 50~60Hz) Remark: Calibration No. 0132 Watt Meters/Sources (Analog/Digital): - * DCW Meters (1mW~20kW) - * ACW Meters (1mW~20kW, 45~65Hz, PF 0.3~1) - * Watt Meter With Clamp (1mW~20kW) - * Power Hi Testers (DCV, DCA, ACV, ACA, DCW, ACW) - DCW Source (1mW~20kW) - ACW Source (1mW~20kW, 10Hz-10kHz) Voltage/Current Sources (Analog/Digital): - * DCV Calibrators/Sources (0~1kV) - * ACV Calibrators/Sources (Up~1kV, 10Hz-30MHz) - * DCA Calibrators/Sources (0~200A) - * ACA Calibrators/Sources (Up~50A, 10Hz-30kHz) - * DC Power Supplies (DCV, DCA) - * AC Power Supplies (ACV, ACA, Freq.) - DC/AC Cut-Off Current Source (Withstanding Testers) * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Approved by: (TM) (TM Leader) Traceability Chart Date: 20-Mar-09 Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Date: 20-Mar-09 Scope: Electrical Calibration (2) (High Voltage, Resistance) National Standard Accredited Laboratories NEC's Highest Standards NEC's Working Standards Customer's Equipment Remark: CSIRO National Measurement Laboratory (NML), Australia National Institute of Metrology (Thailand), NIMT Thai Airway International Public Co., Ltd. (TLAS Accredited No. 0003) Calibration No. 0132 National Metrology Institute of Japan (NMIJ), Japan Agilent Technologies (Japan) (JCSS no.: 0048) Standard Equipment/Ranges: - High Voltage Power Amplifier, Trek 10/10B - Multi-Product Calibrator, Fluke 5520A Range: DCV/ACV: 0.5kV~10kV, 50Hz~60Hz Standard Equipment: - Multi-function Calibrator, Fluke 5720A - Digital Multimeter, Agilent 3458A (Opt-002) - Standard Resistor Set, Fluke 742A's - Standard Resistor Set, IET SRX's series Functions/Ranges: - DCR (0~100MΩ) - DCR (0~1GΩ) - DCR (0~10kΩ) - DCR (0~10MΩ) Standard Equipment/Ranges: - Precision LCR Meter, HP 4284A - Four-Terminal Pair Resistors, HP 42030A Standard Equipment: - DC/AC High Volt. Digital Meter, Kikusui 149-10A - Electrostatic Meter, Trek 347 - High Voltage Probe, Tektronix P6015A - Withstanding Volt. Tester, Kikusui TOS5101 - Digital Multimeter, Agilent 34411A, 34401A Range: DCV/ACV: 0.5kV~10kV, 50Hz~60Hz Standard Equipment: - Multi-function Calibrator, Fluke 5700A - Multi-product Calibrator, Fluke 5520A - Multi-product Calibrator, Fluke 5500A - Digital Multimeter, HP 3458A (Opt-002) - Digital Multimeter, Agilent 34411A, 34401A - Digital Multimeter, Fluke 846A - Standard Resistors, Yokogawa 2792's Series - Calibrator & Source, Keithley 263 - Electrometer, Keithley 617 - Metal Clad Resistor Set, PCN - Decade Resistance Box Set Functions/Ranges: - DCR (0~100MΩ) - DCR (0~1GΩ) - DCR (0~330MΩ) - DCR (0~1GΩ) - DCR (0~1GΩ) - DCR (0~1GΩ) - DCR (1m~100kΩ) - DCR (0~100GΩ) - DCR (0~100GΩ) - DCR (1mΩ~5Ω) - DCR (0~1TΩ) Standard Equipment: - Precision LCR Meter, HP 4284A - LF Impedance Analyzer, HP 4192A - LCR Standard, Sun Jem 6100A - Calibration Standard, HP 16074A - Standard AC Resistor Set, Electrohm - Metal Clad Resistor Set, PCN High Volt. Meters/Sources: - * DC/AC High Volt. Meters - * DC/AC High Volt. Sources - * Withstanding Volt. Testers/ Electrical Safety Testers - Electrostatic Field Meters - High Voltage Probes - High Voltage Dividers - Impulse Testers Range: DCV/ACV: 0.5kV~10kV, 50Hz~60Hz DC Resistance Meters: - * DC Resistance Meters - * Resistance Bridge - * mΩ Testers - * MΩ Testers - * Insulation Testers - * Super MΩ Meters - Wristrap/Shoes Testers - Surface Resistance Testers Range: DCR: 0~10GΩ DC Resistance Sources: - * DC Resistance Calibrators - * DC Resistance Sources - * DC Standard Resistors - * DC Decade Resistance Boxes - * DC Resistors Range: DCR: 0~10GΩ Range: ACR: 1mΩ~100MΩ, 10Hz~13MHz Range: ACR (1mΩ~100MΩ, 10Hz-13MHz) DC Electrometer/Sources: - * DC Electrometers - * Ultra High Res. Meters - * DC High Resistance Sources - * DC Giga/Tera Ohm Meters - * DC Giga/Tera Ohm Resistors - * DC Giga/Tera Ohm Decade Boxes Range: DCR: 1MΩ~1TΩ AC Resistance Meters/Sources: - AC Resistance Meters (LCR Meters) - AC Low Ohm Testers - AC Ground Bond Testers - AC Resistance Sources - AC Resistors Range: ACR: 1mΩ~100MΩ (10Hz~13MHz) * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Approved by: Traceability Chart (TM) Date: 20-Mar-09 Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 20-Mar-09 Scope: Electrical Calibration (3) (Capacitances, Inductances) National Standard Accredited laboratories NEC's Highest Standards NEC's Working Standards Customer's Equipment National Metrology Institute of Japan (NMIJ), Japan Calibration No. 0132 National Institute of Metrology (Thailand), NIMT Agilent Technologies (Japan) (JCSS no.: 0048) Standard Equipment/Ranges: 4-Terminal Standard Capacitor Set, HP16380A, 16380C Range: 1pF~1µF, 10Hz~13MHz Standard Equipment/Ranges: 4-Terminal Standard Capacitor, Quadtech 1417 Range: 1µF~100mF, 100Hz,120Hz,1kHz Standard Equipment/Ranges: - Precision LCR Meter, HP4284A - Standard Self Inductor Set, Ando RS's Series Standard Equipment: Functions/Ranges: - 1pF~1µF - 4-T Standard Capacitor Set, HP16380A, 16380C - 0.19nF~110mF - Multi-product Calibrator, Fluke 5520A - 0.33nF~1.1mF - Multi-product Calibrator, Fluke 5500A - 1pF~100mF - Precision LCR Meter, HP 4284A - 1pF~100mF - LF Impedance Analyzer, HP 4192A - 100pF~100mF - LCR Standard, Sun Jem 6100A - 30pF~60pF - Standard Capacitor Set, Shoshin - 40pF~1.1µF - Decade Capacitor, HP 4440B - 1pF~1µF - Precision Decade Capacitor General Radio 1413 Standard Equipment: Capacitance Meters: - * 2-Terminal Type LCR Meters (Capacitance) - * 4-Terminal Type LCR Meters (Capacitance) - * Digital Multimeters (Capacitance) - * Capacitance % Meters Inductance Meters: - * 2-Terminal Type LCR Meters (Inductance) - * 4-Terminal Type LCR Meters (Inductance) - * Digital Multimeters (Inductance) - * Inductance Meters Capacitance Sources: - * 2-Terminal Type Standard Capacitors - * 4-Terminal Type Standard Capacitors - * Capacitance Calibrators/Sources - * Decade Capacitance Boxes - * Capacitors Range: 1pF~110mF, 10Hz~13MHz - Precision LCR Meter, HP 4284A - LF Impedance Analyzer, HP 4192A - Decade Inductor, ANDO AM3301 Range: 100µH~1H, 100Hz~100kHz 10nH~1kH, (100Hz~100kHz) 100µH~1H, (100Hz~10kHz) Functions/Ranges: - 10nH ~ 1kH (100Hz ~ 100kHz) - 10nH ~ 100kH (100Hz ~ 100kHz) - 1mH ~ 1H (100Hz ~ 100kHz) Inductance Sources: - * Standard Inductors - * Inductance Sources - * Decade Inductance Boxes - * Inductors Range: 1µH~10H, 100Hz~100kHz Range: 1pF~110mF, 10Hz~13MHz Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry) FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Approved by: Traceability Chart Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 22-Nov-07 (TM) (TM Leader) Date: 24-Mar-09 Date: 24-Mar-09 Scope: Electrical Calibration (4) (Frequency, RF Power) National Standard National Metrology Institute of Japan (NMIJ), Japan National Institute of Metrology (Thailand), NIMT Agilent Technologies (Japan) (JCSS no.: 0048) Accredited Laboratories NEC's Highest Standards Standard Equipment - Rubidium Frequency Standard, R&S XSRM - Frequency Converter, R&S XSRM # - GPS Time and Frequency Standard Receiver, HP 58503A Standard Equipment: NEC's Working Standards Customer's Equipment - Rubidium Frequency Standard, Sansei FSR-101 Universal Counter, HP 53132A (Opt-012-030) Universal Counter, Advantest TR5822 Microwave Frequency Counter, HP 5352B Synthesized Function Generator, HP 3325B Synthesizer-Level Generator, Anritsu MG443B Signal Generator, HP ESG-4000A ESGD Series Signal Generator, HP E4433B Synthesized Sweeper, HP 8340B Synthesized Sweeper, HP 83620A Synthesized Sweeper, HP 83640A Ranges: - Freq.: 5 MHz - Freq.: 0.1~10MHz - Freq.: 10 MHz Functions/Ranges: - Freq.: 1MHz, 5MHz, 10MHz - Freq.: 1Hz ~ 3GHz - Freq.: 1Hz ~ 3GHz - Freq.: 100MHz ~ 40GHz - Freq.: 1Hz ~ 21MHz - Freq.: 10H ~ 30MHz - Freq.: 100kHz ~ 4GHz - Freq.: 250kHz ~ 4GHz - Freq.: 10MHz ~ 26.5GHz - Freq.: 10MHz ~ 20GHz - Freq.: 10MHz ~ 40GHz Frequency Meters/Sources: - * Frequency / Universal Counters - * Microwave / Time Interval Counters - * Frequency Standards / Quartz Testers - * Frequency Sources from Other Instrument - * Digital Multimeters (Frequency) / Frequency Meters - Timers / Stopwatches - Tachometers / Stroboscopes Range: 1Hz~40GHz Remark: Calibration No. 0132 Standard Equipment - Power Sensor, HP 8484A - Power Sensor, HP 8481A - Power Sensor, HP 8482A RF Power Ranges: - 50Ω: 0.1nW~10µW (10MHz~18GHz) - 50Ω, 1µW~100mW (10MHz~18GHz) - 50Ω, 1µW~100mW-(100kHz~4.2GHz) Standard Equipment RF Power Ranges: - Power Sensor, HP E4413A - 50Ω, 0.1nW~100mW(100MHz~26.5GHz) - Power Sensor, HP 8487A - 50Ω, 1µW~100mW (50MHz~50GHz) - Power Sensor, HP 8483A - 75Ω, 1µW~100mW (100kHz~2GHz) Standard Equipment: - RF Power Meter, HP436A, E4419B, EPM442A RF Power Meter, Anritsu ML4803A Power Sensor, HP 8482A, HP 8482B Power Sensor, HP E4412A, HP E9301A Power Sensor, Anritsu MA4601A, Anritsu MA4602A Range Calibrator, HP 11683A, HP 8477A Range Calibrator, Anritsu MA4001A Measuring Receiver, HP 8902A/11722A Spectrum Analyzer, HP8593E ,HP8564E, HPE4406A Spectrum Analyzer, Advantest R3465 Selective Level Meter, Anritsu ML422C Signal Generator, HP 3325B, HP ESG-4000A, HP E4433B, HP 8340B Signal Generator, HP 83620A, HP 83640A Syntesized Level Generator, Anritsu MG443B, RF Power Amplifier, 25WI000M7 RF Power Splitter, HP 11667A, HP 11667B RF Power Meters: Example of Instrument (RF Measurement Function): - RF Power Meters - RF Power Sensors - Spectrum Analyzers - RF Level Meters - Modulation Analyzer - Radio Communication Analyzers - Site Masters - Network Analyzers Range: -100dBm~44dBm, 100Hz~40GHz, 50Ω, 75Ω, 600Ω NEC Purchasing Ltd. (Japan) Functions/Ranges: - RF RF RF RF RF RF RF RF RF RF RF RF RF RF RF RF Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: Power: 50Ω, 0.1nW - 25W (100kHz - 40GHz) 75Ω, 0.1nW - 100mW (100kHz - 2GHz) 50Ω, 0.1µW - 100mW (10MHz - 18GHz) 50Ω, 0.1µW - 100mW (10MHz - 6GHz) 75Ω, 0.1nW - 100mW (100kHz - 2GHz) 50Ω, 0.1nW - 25W (100kHz - 40GHz) 75Ω, 0.1nW - 100mW (100kHz - 2GHz) 50Ω, -127dBm~30dBm (100kHz - 1.3GHz) 50Ω, -120dBm~30dBm (30Hz - 40GHz) 75Ω, -120dBm~30dBm (30Hz - 40GHz) 50~600Ω, -120dBm~30dBm (50Hz - 30MHz) 50Ω, -120dBm~30dBm (100kHz - 40GHz) 50Ω, -120dBm~30dBm (100kHz - 40GHz) 50~600Ω, -120dBm~30dBm (50Hz - 30MHz) 50Ω, Max. 25W (25MHz - 1GHz) 50Ω, -120dBm~30dBm (100kHz - 40GHz) RF Power Sources: Example of Instrument (RF Source Function): - Signal Generators / Function Generators - Synthesized Sweepers - Pulse Generators - RF Oscillators - Synthesized Level Generators - Network Analyzers - RF Power Amplifier / Splitter Range: -100dBm~44dBm, 100Hz~40GHz, 50Ω, 75Ω, 600Ω * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). # No traceability to national standard FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Approved by: Traceability Chart 22-Nov-07 (TM) Date: 24-Mar-09 Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 24-Mar-09 Scope: Electrical Calibration (5) (RF Att./SWR/TV/Tel/Flutter/Jitter/LF) National Standard NEC's Highest Standards NEC Purchasing Ltd. (Japan) Standard Equipment Ranges: - 50Ω: - Fixed Attennuator Set, Weinschel 44's - 50Ω: - Fixed Attennuator Set, Agilent 8493C - 50Ω: - Fixed Attennuator Set, Wiltron 41KC-S - 75Ω: - Decade Attennuator, Anritsu MN61B - 50Ω: - Termination, Wiltron 26N50, 26NF50 - 50Ω: - Termination, Wiltron 28A50 - 50Ω: - Termination, Maury 351A, 351B - 50Ω: - Termination, Wiltron 28K50, 28KF50 - 75Ω: - Termination, Wiltron 26N75, 26NF75 - 50Ω: - Termination, HP 902C, 902D Standard Equipment: NEC's Working Standards Standard Equipment: 10~40dB (DC~18GHz) 30~40dB (DC~26.5GHz) 3~20dB (DC~40GHz) 0~91dB (DC~1.5GHz) Type N (DC~18GHz) Type APC 7mm (DC~18GHz) Type BNC (DC~10GHz) Type K (DC~40GHz) Type N (DC~8GHz) Type 3.5mm (DC~26.5GHz) Ranges: - Fixed Att. Set, HP 8492A Series Fixed Att. Set, Tektronix 011-0059 Fixed Att. Set, Weinschel Model 2 Series VHF Attennuator, HP 355C/355D Decade Attenuator, Ando AL352 - Network Analyzer, HP 8753D Network Analyzer, Wiltron 360 Calibration Kit, HP85031B,85032B,85036B Calibration Kit, Wiltron 3652 - RF RF RF RF RF RF RF RF RF Attenuators Attenuators Attenuators Attenuators Termination/Calibration Kit Termination/Calibration Kit Impedance from Signal Sources Impedance from Signal Meters Attenuation from Signal Sources - RF Attenuation from Signal Meters Remark: - - Noise Generator Agilent N4001A Standard Equipment: - 50Ω BNC, N, APC 3.5mm (0~120dB, DC~40GHz) - 600/75Ω Balance (0~91dB, DC~700kHz) - Noise Figure Meter, Agilent N8972A - PowerAmplifier, Agilent 8447D - 50Ω BNC, N, APC 3.5mm (0~120dB, DC~40GHz) RF Attenuation/Impedance From RF Power Sources/Meters: Customer's Equipment National Institute of Metrology (Thailand), NIMT National Metrology Institute of Japan (NMIJ), Japan Accredited Laboratories Calibration No. 0132 50Ω: 0~100dB, DC~40GHz 75Ω: 0~90dB, DC~1.5GHz 75Ω Balance: 0~91dB, DC~700kHz 600Ω Balance: 0~91dB, DC~150kHz 50Ω: DC~40GHz 75Ω: DC~1.5GHz 50Ω: DC~40GHz, 75Ω: DC~1.5GHz 50Ω: DC~40GHz, 75Ω: DC~1.5GHz 50Ω: 0~100dB, DC~40GHz, 75Ω: 0~90dB, DC~1.5GHz - 50Ω: 0~100dB, DC~40GHz, 75Ω: 0~90dB, DC~1.5GHz Noise Meters/Sources: - Noise Figure Analyzers - Noise Sources/Generators Standard Equipment: Ranges: Level: - Digital Multimeter, Agilent 3458A - AC Measureing Standard, Fluke 5790A+Wide Band - Multi-Function Calibrator, Fluke 5720A - Multi-Function Calibrator, Fluke 57020A+Wide Band Level: - DCV/ACV: Up~700V (10Hz~10MHz) - ACV: Up~1kV (10Hz~30MHz) - DCV/ACV: Up~1kV (10Hz~1MHz) - DCV/ACV: Up~1kV (10Hz~30MHz) Frequency: - Rubidium Frequency Standard, R&S XSRM Frequency: - Freq.: 0.1MHz, 1MHz, 5MHz, 10MHz Standard Equipment: - Signal Generator, Tektronix TG2000 - Mixed Signal Audio Measurment Set, Tektronix AM700 - NTSC TV Generator, Tektronix 1410 - PAL TV Generator, Tektronix 1411 - Video Measurement System,Tektronix VM700T TV Signal Analyzers/ Sources Instruments: - * PAL Pattern Generators - * NTSC Pattern Generators - * PAL Vector Scopes - * NTSC Vector Scopes - * Video Generators - * Video Analyzers - * Video Noise Meters - * Video Pattern Generators - * Video Sweep Generators Standard Equipment: - Multimeter, HP3458A, 34411A, 34401A Multi Product Calibrator, 5520A, 5500A Oscilloscope,Tektronix TDS684B,TDS540A Measuring Receiver HP8902A Modulation Analyzer 8901B Audio Analyzer, VP7725A, HP 8903B Telephone Unit Tester, Ando AE9303 Impulse Sender, Ando AE-3106 Wow Flutter/CD/DVD Jitter Calibrator,Minato 3101, Act 3901 Rubidium Frequency Standard, Sansei FSR-101 Universal Counter, HP53132A.012.030, Advantest TR5822 Other LF/Audio/Modulation Instruments: - * Audio Analyzers/Generators - * CD Jitter Meters/Calibrators - * CD/MD Tracking Offset/Phase Meters/Generators - * DVD Jitter Meters/Calibrators - * VTR Jitter Meters/Generators - * WOW Flutter Meters/Generators - * Telephone Unit Analyzers/Generators - * Bell Ringer Analyzers/Generators - * Digital/Analog Radio Testers/generators - * AM/FM/Phase Modulation Analyzers/Generators - * Distortion Analyzers/Generators - * Oscilloscopes/Oscilloscopes Calibrators * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). * Accredited scopes only ACV, DCV and frequency only FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Approved by: Traceability Chart 22-Nov-07 (TM) Date: 24-Mar-09 Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 24-Mar-09 Scope: Electrical Calibration (6) (Optical) National Standard Accredited Laboratories NEC's Highest Standards National Metrology Institute of Japan (NMIJ), Japan National Institute of Metrology (Thailand), NIMT Japan Quality Assurance Organization (JQA) / Agilent Technologies (Japan) / EXFO Asia Pacific PTE Ltd. (Japan) Primary Wavelength Meter WA-1150/WFM-601M Primary Optical Attenuator Agilent 8158B/8156A - Lightwave Multi-Meter, Agilent 8153A - Multi-Wavelength Meter, Agilent 86120C - Lightwave Measurement System, Agilent 8164A - Lightwave Multimeter, Agilent 8163A - Optical Multimeter, Ando AQ2140 (1300~1550 nm +/- 0.003 nm, 1~60dB) NEC's Working Standards Optical Attenuator, Agilent 8156A (1300~1550 nm, 1~60dB) Optical Power Sensors, Agilent 81624A (1300~1550 nm, +10~-90dB) Optical Attenuator, Agilent 8156A / Anritsu MN9605C (1300~1550 nm, 1~60dB) Optical Power Sensors, Agilent 81521B/81525A/81532A (1300~1550 nm, +27~-110dB) - Laser Source, Agilent 81640A/81650A/81689A - LD Source, Anritsu MG0938C / Ando AQ4212 / Anritsu MG9002A (1310, 1510~1640 nm) - Optical Component/Optical Time Domain Reflectmeter Polarization Controller Return Loss Module Optical Directinal Coupler - Data Communication/Digital Communication Analyzer - 20GHz Optical/Electrical Converter - SONET/SDH Analyzer Optical Wavelength / Optical Components / Optical Powers: - Optical Attenuators - Laser Sources / Lightwave Meters - Optical Direction Couplers - Lightwave Switchs - Optical Grating Filters - Lightwave Transmitters / Receivers - N2X Card - Optical Spectrum Analyzers - NIC - Optical Time Domain Reflectmeters - Pulse Pattern Gen - Plug in Modules - Return Loss - Polarization Power Attenuation Wavelength Customer's Equipment Calibration No. 0132 Optical Spectrum Analyzer, Anritsu MS9710B (1300~1550 nm, -10~-50dB) - Agilent 8147 Agilent 8169 Agilent 81534A Anritsu MN9604B - Agilent 83480A/83485A (2.488Gb/s), 83480A/83485B (9.953Gb/s) - Agilent 83440C (DC~20GHz) - Anritsu MP1570A (10G) - Communication Test Sets Error Detectors Infiniium DCA Laser Diode Drivers OmniBER Communication Analyzers Optical Power Meters / Power Sensors OTDR - Single Mode Clock Recovery SONET Transmittion Test Set SpectralBER DWDM Module SPLTR SunSet SunLite T-Bird T-Carrier Analyzers FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: (TM) Traceability Chart Approved by: Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 02-Mar-09 Date: 02-Mar-09 Scope: Dimensional Calibration (1) National Standard NEC's Highest Standards NEC's Working Standards Customer's Equipment National Metrology Institute of Japan (NMIJ) National Measurement Institute (NMIA), Australia - Long Gauge Block Set (Grade K, Range 100~500mm) (Uncertainty: 0.04~0.20µm) - Gauge Block Set (Grade K, Range 0.1~100mm) (Uncertainty: 0.02~0.04µm) - Laser Hologauge - Gauge Block Set (Grade K, 0, 1) - Electronic Comparator - Precision Surface Plate (Grade 0) - Gauge Block Set (Grade 0, 1, 2) - Long Gauge Block Set (Grade 0, 1) - Caliper Checkers - Depth Micro-Checkers - Precision Surface Plates (Grade 0) - Small Angle Generator - Laser Hologauge - Digimatic Indicator - Gauge Block Set (Grade 0, 1, 2) (Uncertainty: 0.02~0.20µm) (Uncertainty: 0.1~0.2µm) (Uncertainty: 0.02~0.20µm) (Uncertainty: 0.07~3.0µm) (Uncertainty: 0.07~2.0µm) - Gauge Blocks * - Long Gauge Block (Steel, Ceramic, Carbide) Grade 0, 1, 2 - Calibration Testers * - Dial Gauge Testers * - Coating Thickness Plates - Linear Probes - Caliper Checkers* - Depth Micro-Checkers* - Height Masters - Riser Blocks - Check Masters - Master Bars - Setting Bars Range: 0~500mm Range: 0~600mm Remark: National Institute of Metrology (Thailand), NIMT - Gauge Block Set (Grade K, 0) - Electronic Comparator - Laser Hologauge Range: 0.1~300mm Calibration No. 0132 - Outside Micrometers (0~1000mm)* - Inside Micrometers (0~300mm)* - Depth Micrometers (0~300mm)* - Thickness Gauges (0~100mm)* - Height Gauges (0~1000mm)* - Calipers (0~ 1500mm)* - Depth Gauges (0~600mm) - Caliper Gauges (0~300mm) - Micrometer Heads (0~100mm) - Electrical Comparators (0~10mm)* - Precision Levels (0~5mm/m)* - Electric Levels (0~5mm/m)* - Gauge Block Set (Grade 0, 1, 2) - Long Gauge Block Set (Grade 0, 1) - Precision Surface Plates (Grade 0) (Uncertainty: 0.07~0.20µm) Others - Snap Gauges - Straightness Edge - Horizontal Machines - Length Measuring Machines - Coating Thickness Gauges * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: (TM) Traceability Chart Approved by: Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 02-Mar-09 Date: 02-Mar-09 Calibration No. 0132 Scope: Dimensional Calibration (2) NEC's Highest Standards Swiss Federal Office of Metrology (OFMET), Switzerland National Institute of Metrology (Thailand), NIMT National Standard Gauge Block Set (Grade K) (Uncertainty: 0.02~0.04µm) Laser Hologauge (Uncertainty: 0.1~0.2µm) NEC's Working Standards Calibration Testers - Standard Pin Gauge Set - Laser Scan Micrometer - Standard Glass Scale 3-D Master Standard Tape Uncertainty: 0.4µm Uncertainty: 0.2~0.5µm Uncertainty: 0.3µm Uncertainty: 0.5µm Uncertainty: 0.5µm Digimatic Digital Indicator Indicator Uncertainty: 1.0µm - Profile Projector - Angle Gauge Ring Gauge Set Uncertainty: 1.0µm Uncertainty: 1.0µm Uncertainty: 1.0µm Uncertainty: 0.5µm - Feeler Gauges* - Dial Gauges* - Dial Test Indicators* - Bore Gauges - Cylinder Gauges - Pin Gauges* - Plug Gauges* - Laser Scan Micrometers - Three Wires* - Thread Plug Gauges - Thread Ring Gauges - Profile Projectors - Measuring Microsocopes - Scale Loops - Glass Scales - Protactors - Angle Gauges - Radius Gauges - Taper Gauges - Metal Rules Range: 0.1~10mm Range: 0~100mm Range: 0.1~100mm Range: 1~100mm Range: 0~300mm Range: 0~300mm Range: 0~300mm Customer's Equipment Remark: - Working Glass Scale - Microscope Calibrator - 3-W Set - Thread Plug Gauge Set Electronic Level Meter Uncertainty: 0.5µm - Holtest* - CMM - Steel Tape - Metal Rule Text Tile Tape - Surface Plates Range: 2~100mm Range: 0~1000mm Range: >300mm Size: 300*300mm up * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Approved by: (TM) Traceability Chart Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 19-Mar-09 Date: 19-Mar-09 Scope: Force & Torque Calibration National Institute of Metrology (Thailand), NIMT National Standard NEC's Highest Standards NEC's Working Standards Calibration No. 0132 - Standard Weight Set, OIML Class E2 (Mettler-Toledo) Range : 1mg~20kg - Standard Weight Set, OIML Class E2, F1 (Mettler-Toledo) - Standard Weight Set, OIML Class F1 (Kern) - Standard Weight Set, OIML Class F2 (Moriya) - Standard Weight Set, OIML Class M1 (Moriya) - Hook / Slot Weight Set (RRK) - Gauge Block Set Grade K Range : 0.5mm~500mm - Hook / Slot Weight Set (SSK) Range: 0~200kg - Beam Standard (Hios, Kanon) Range: 1cm~20cm - Digital Torque Tester (HIOS) - Digital Torque Tester (KANON) - Digital Torque Tester (Tohnichi) - Digital Force Indicator (HBM) - Load Cell Standard (HBM) Range: 0~10kN Range: 0~2,000kg.cm Range: 1mg~500kg Customer's Equipment Force Measuring Instrument - Push-Pull Scales * - Tension Gauges * - Dial Tension Gauges * - Force / Digital Force Gauge * Torque Instrument - Digital / Mechanical Torque Testers - Torque Gauges - Torque Wrenches - Torque Drivers - Torque Screw Drivers Force Machines (On-site) - Tensile Testing Machines - Autograph Machines Range: 0~10kN Range: 0~500kgf Range: 0~2,000kgf.cm Remark: * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: (TM) Traceability Chart Approved by: (TM Leader) Date: 16-Mar-09 Date: 16-Mar-09 Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Scope: Mass Calibration National Standard National Institute of Metrology (Thailand), NIMT Swiss Federal Office of Metrology (OFMET) - Standard Weight Set, OIML Class E2 (Mettler-Toledo) Range : 1mg~20kg NEC's Highest Standards NEC's Working Standards Physikalisch Technische Bundesanstalt (PTB), Germany Calibration No. 0132 - Standard Weight Set, OIML Class E2 (Mettler-Toledo) - Mass Comparator, Mettler-Toledo, AT201 - Mass Comparator, Mettler-Toledo, PR2004 - Mass Comparator, Mettler-Toledo, KA30-3/P - Standard Weight Set, OIML Class F1 (Mettler-Toledo) - Standard Weight Set, OIML Class F1 (Kern) - Mass Comparator, Mettler-Toledo, AT201 - Mass Comparator, Mettler-Toledo, PR2004 - Mass Comparator, Mettler-Toledo, KA30-3/P Range: 1mg~20kg - Standard Weight Set, OIML Class E2, F1 (Mettler-Toledo) - Standard Weight Set, OIML Class F1 (Kern) - Standard Weight Set, OIML Class F2 (Moriya) Standard Weight Set, OIML Class M1 (Moriya) Range: 1mg~20kg Range: 1mg~500kg Customer's Equipment Remark: - Steel Weights * - Brass Weights * - Stainless Steel Weights * - Other Material Made Weights * OIML Class F1, F2 - Steel Weights * - Brass Weights * - Stainless Steel Weights * - Other Material Made Weights * OIML Class F2, M1, M2, M3, No-Class - Electronic Balances * - Spring Balances * - Other Balances * Range: 1mg~20kg Range: 1mg~20kg Range: 0g~500kg * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: (TM) Date: 19-Mar-09 Traceability Chart Approved by: (TM Leader) Date: 19-Mar-09 Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 Scope: Other Scopes of Calibration National Institute of Metrology (Thailand), NIMT National Standard NEC's Highest Standards NEC's Working Standards Standard Weight Set, OIML Class E2 (Mettler-Toledo) Duro Meter Tester (Teclock) Range: 0~100o Customer's Equipment (JIS / ASTM Type) (0~100 o) National Institute of Standard and Technology, U.S.A. National Metrology Institute of Japan (NMIJ), Japan pH Solution Standard (Mettler-Toledo) Standard Liquid for Calibrating Viscometers (Nippon Grease) (pH 4~10) (JS 500 / 1,000 / 2,000 / 14,000 / 160,000) Digital Multimeter (Agilent 3458A) - Hydraulic Dead Weight Tester (Nagano) - Pressure Calibrator (Fluke) - Pressure Module (Fluke) Master Ball (Tokyo Semitsu) E-MG-R054) Roughness Standard (Tokyo Semitsu) Standard Block for Hardness (NIMT) - Pressure Gauges - Pressure Transducer - Pressure Switch - Pressure Indicator (0~50kgf.cm2) or quivalent unit - Conductivity Solution Standard (Mettler-Toledo) - Decade Resistance Boxes Range: 0~50kgf.cm2 - Rubber Hardness Testers - Duro Meters Calibration No. 0132 (0.1nS~1S) Roundness Testers Roughess Testers Hardness Testing Machines (Vicker / Rockwell) Conductivity (With Probes) pH Meter (With Probes) - Viscosity Testers - Viscosity Meters (HMV, HRC, HRB) (0.1nS~1S) (pH 4~10) (125~147,877 mPa.s) (Ra, Ry) Remark: FEZ-0009-G-Form-03/V5 /01/04/08 Prepared by: Traceability Chart Approved by: (TM) Calibration Center NEC Corporation (Thailand) Ltd. 75/107 M. 11, Paholyothin Rd., Klong 1, Klong Luang, Pathumthani 12120 Tel. (66) 2-529-2460, Fax. (66) 2-529-2466 (TM Leader) Date: 20-Mar-09 Date: 20-Mar-09 Scope: Temperature Calibration National Institute of Metrology (Thailand), NIMT National Standard - SPRT Standard (Hart Scientific, 5626) - Type S Standard Thermocouple (High Temp.) - High Precision Thermo-Hygrometer (Fluke 1621A) NEC's Highest Standards NEC's Working Standards Customer's Equipment Standard Sensors and Thermometers: - PRT Standard Sensor (Asahi), Pt-100 - PRT Standard Sensor (Anritsu), Pt-100 - PRT Standard Sensor (Netsushin), Pt-100 - Type S Thermocouple (High Temp.) - Type T Thermocouple Set (RS) - High Precision LIG Thermometers (Nippon Kei) - Black Stack Thermometer (Hart 1560, 2562) - Reference Junction Set (Type E, J, K, N, R, S, T) - Data Logger With RTD Sensor (Agilent 34970A) - Hybrid Recorder With Type T Sensors (Yokogawa) - Digital Thermometer (Yokogawa 7563-21) - Humidity Transmitters (Rense) Temperature Sensors: - Thermocouple Sensors * - Thermocouple Extension Wire* (Type E / J / K / N / R / S / T) - RTD Sensors * Range: -20oC~700oC Remark: Calibration No. 0132 Thermometers: - Liquid-in-glass Thermometers * - Thermometer With Sensors * (Analog / Digital) - Recorder With Sensors * - Surface Thermometers Range: -20oC~700oC - Multi-Function Calibrator (Fluke 5720A) - DCV Standard (Fluke 732B) Temperature Sources: - Dry Block Calibrator (Hart Scientific, 9105) Dry Block Calibrator (Hart Scientific, 9122A) Surface Calibrator (Anritsu ACSII) Liquid Bath (Jubalo) Micro Bath (Hart Scientific, 6102 7103) Temperature / Humidity Controlled Chamber (Espec, PR1KP) Temperature Sources: - Dry Block Calibrators * - Liquid Bath * - Chambers, Oven * - Incubators, Autoclave * Range: -40oC~1,000oC Thermo-Hygro: - Thermo-Hygrographes - Thermo-Hygrometers (Analog / Digital) - Humidity Transmitter Range: Tem. -20oC~50oC Hum. 20%~90%rh Standard Simulators: - Multi-Product calibrators (Fluke 5520A) - Process Calibrator (Fluke 744) Standard Indicators: - Digital Multimeter (Agilent 3458A) - Digital Multimeter (Fluke 8846A) Temperature Indicators / Simulators: - Hybrid Recorders * - Reflow / Soldering Testers * - Data Logger / Thermometer * - Process Calibrators * - Temperature Calibrators * Range: TC all type, RTD all type * ISO/IEC 17025 accredited scopes by Thai Laboratory Accreditation Scheme (Thai Industrial Standards Institute, Ministry of Industry). FEZ-0009-G-Form-03/V5 /01/04/08