Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Buck converter wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Resilient control systems wikipedia , lookup
Distributed control system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power electronics wikipedia , lookup
Regenerative circuit wikipedia , lookup
Control theory wikipedia , lookup
Hubbell Industrial Controls, Inc. Radio Crane Control Systems Hubbell Radio Remote Control Systems Catalog 31.100 • September 2000 Replaces: Brochure 31100 of June 96 Catalog Sheet 31100 AC Compact Radio Catalog Sheet 31100 Diagnostic Display Catalog Sheet 31132 License-Free Radio 31.110 – AC Compact Style with Micro-Controller Hubbell Radio Control Systems use the latest micro-controller technology and ultra reliable Manchester II (bi-phase) digital FM signal coding. Each radio control system operates on a licensed frequency in the 72 to 76 MHz or the 450 to 470 MHz bands. The security of any remote control system is of the utmost importance. Hubbell radio control systems’ security is enhanced through multiple checks before any function can become operational: 31.120 – DC Compact Style with Micro-Controller • The received signal must be of the proper frequency. • The received message must have the proper address and must be in the correct format. • The receiver calculated CRC code must be identical to the CRC code calculated by the transmitter and sent as part of each message. • The preceding items must be met and all transmitter lever switches must be centered before the Crane Main Contactor can be energized. • To continue or change an energized function, requires the receipt of a “valid message” prior to timeout of the message timer. If no valid message is received, the system turns off all outputs. 31.130 AC License-Free with Belt-Clip Transmitter • Two separate “watchdog timers” assure that all outputs are switched off in case of a receiver malfunction. HUBBELL Radio Crane Control Systems A typical radio crane control system consists of a portable transmitter carried by the operator, and a receiver installed on the crane. Each system operates on a licensed frequency in the 72 to 76 MHz or the 450 to 470 MHz bands. The receiver is crystal controlled. A synthesized receiver is an option for 72– 76 MHz. An 8-bit micro-controller, operating at 4.9 MHz, decodes the signal coming from the rf module and passes the output commands through the I/O boards to the output modules. The ac receiver uses 120V ac Solid State Relay output modules. No interface relays are needed for controllers up to and including size 4 contactors. An LED shows the status of the output module. A stepless, analog output module is available, as is a relay card using electro-mechanical output relays. Input modules monitor the status of the 120V ac Control Power, Main Contactor, plus M, F, R for each motion. The output modules on the dc receiver are 270V dc Solid State Relays. No interface relays are needed for controllers up to and including size 5 contactors. The output module status is shown by LED’s: red = output activated; green = output current flowing. Input modules monitor the status of the 250V dc Control Power, Main Contactor, plus M, F, R for each motion. Diagnostic Display Module Standard Features • For new and existing microprocessor based crane and locomotive controls • 2 line x 20 character backlit LCD display for message and time stamp • English descriptions of faults • Display mounted in receiver rack or on microprocessor unit • Fault logging with local or remote down load capability • Control button for setting battery backed real time clock Each transmitter/receiver pair has their own unique 7–bit address code (the first seven bits of the digital message). Unless the transmitter address and receiver address are identical, the system will not respond to any command, regardless of the frequency. Message integrity is assured by use of an 8-bit Cyclic Redundancy Check (CRC) code. Cyclic redundancy check is a division performed in the transmitter logic, which produces a remainder that is transmitted last as the 8-bit check code. The receiver logic performs a like division on the received message (without the CRC) to produce its own 8–bit CRC code. If the two CRC codes are identical, the received message will be decoded as a “valid message” and the appropriate outputs will be turned on or off, as directed. The crystal controlled transmitter uses an 8-bit micro-controller, operating at 2.5 MHz, to scan the command switches. All major function switches must be in the center or “off” position before the Crane Main Contactor can be energized. When the transmitter is “on” and the command switches are “off” or centered, then the transmitter actually sends a “stop” command to the system. Motion can occur only with the removal of the “stop” command and the addition of a speed point/directional command within a certain time sequence. Using the key-switch to turn off the transmitter power causes the transmitter to send five consecutive “E-STOP” messages before shutting down. The switch position data is transmitted as a digital signal at the licensed frequency, using Manchester II coding. The digital message has a specific format and is repeated 2 to 9 times per second. The repeat rate is programmable. The transmitter is turned off between messages to conserve battery life and rf spectrum. This makes it possible to have several transmitters operating in the same area, on the same frequency, with practically no interference because of the different transmission rates. The unique address code of each transmitter and receiver assures that only the matching receiver responds to the radio commands. All other signals on the same frequency are ignored. The use of Manchester II (bi-phase) digital FM signal coding makes the message less sensitive to corruption from interference. Please consult Tech Info 31.100, page 2, for a detailed discussion on the message format and Manchester II coding. Hubbell Industrial Control Solutions Typical Fault Messages Start-up & Run Mode Status/Faults POWER-UP WAITING NO MSG 16:21:56 DIAG TEST OK NO MSG FROM TX 16:21:56 NORMAL OPERATION MSG OK 6.2 MPS 16:21:56 TIMED OUT NO MSG FROM TX 16:21:56 TROLLEY TX SW NOT CENTERED 16:21:56 BRIDGE M STUCK ON FAULT 16:21:56 BRIDGE M STUCK OFF FAULT 16:21:56 RUN RELAY STUCK OFF RUN FAULT 16:21:56 RUN RELAY STUCK ON RUN FAULT 16:21:56 RUN OUTPUT STUCK ON RESET FAULT 16:21:56 WATCHDOG MONITOR MCB FAULT 16:21:56 MCB SELF TEST RAM FAILURE 16:21:56 31.110 31.120 31.130 120V AC, 72 or 450 mHz, Compact Style with Micro-Controller 250V DC, 72 or 450 mHz, Compact Style with Micro-Controller 120V AC, License-Free with Micro-Controller Hubbell Performance The Hubbell Microprocessor Radio Crane Control Systems features a microcomputer with status display and built-in diagnostics along with our high speed, digital, biphase modulation to provide reliable, efficient and economical operation of electric overhead cranes from a portable transmitter. • System approved for operation under FCC Part 15 rules — no user license required. • Digital FM signal — exceptional immunity to noise. Benefits • State of the art design — surface mount, micro-controller electronics. • High speed microprocessor • Bi-phase, digital signal transmission Increased Flexibility • Very compact receiver • Fits even the smallest crane Internal Diagnostics • Run by microprocessor on internal programs • Run by microprocessor on commands and I/O • Power-up diagnostics • Continuous monitoring Operational Status • English language diagnostic display Transmitter • High speed microprocessor • Compact, light weight • Up to four lever switch control functions • Toggle switch and pushbutton functions • Easy to Maintain — Self diagnostics identify problem areas via the status display. • Fast Response — High Speed data rate offers fast, responsive operation. • Frequency Conservation — Up to four systems can share the same radio frequency, which also saves on spare parts requirements. • Security — 6000+ address codes available. • Auto power off extends battery life. • Extremely compact and cost effective systems. Select one of several single-speed transmitters or a two-speed transmitter: • Key-Ring - with 1 or 4 buttons • Belt-Clip - with 1, 2, 3, 4, or 6 buttons • Improved Control — Remote control takes the operator out of the cab providing him with improved visibility and total control from a ground floor position. • Hand-Held - with 6 or 8 buttons • Simple Operation — Portable, lightweight transmitter is easier to operate than manual cab controls. Select receivers with the number of output relays to match the transmitter functions. A flexible half–wave antenna mounts directly to the receiver by BNC connector. All receivers are rated NEMA 4X for indoor/outdoor use. • Hand-Held -- with 8 two-speed buttons. All transmitters are rated NEMA 3 for indoor/outdoor use. Please refer to Spec Sheet 31.130 for more detailed information on this equipment. Belt-Clip Key-Ring Hand-Held Typical 250V DC Output Section Hubbell Industrial Control Solutions Outline Drawings Specifcations Typical to All Systems 0.44 DIA. 20.00 14.00 3.25 8.00 7 8 9 Frequency Range ......................... 72–76 MHz or 450–470 MHz Channel Availability ...................... 30 @ 72 MHz, 8 protected, over 200 shared @ 450 MHz Frequency Stability ....................... ±10 ppm Sensitivity ................................... 1 µv @ 20 dB quieting nominal Data Reception ............................ compatible with Hubbell transmitters Modulation ................................. Manchester II (bi-phase) Baud Rate .................................. 4800 bps Message Format .......................... preamble, sync, start flag, address, control, CRC check code 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12 4301 Cheyenne Drive, Archdale, N.C. 27263 + - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 0 1 2 3 4 5 6 7 8 9 10 11 23 22 21 20 19 18 17 16 15 14 13 12 P1 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 HUBBELL HUBBELL Hubbell Industrial Controls, Inc. P2 0 23 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20.00 21.25 6 #6/.138;TPI=40/32;CHSD=.147;TDSF=.1130;TDSC=.1065 #10/.190;TPI=32/24;CHSD=.201;TDSF=.1590;TDSC=.1495 A1 13 23 33 43 14 24 34 44 F3-1 5 F2-1 4 F1-1 3 F3-2 2 F2-2 1 F1-2 SER. AC MODEL NO. 015069 PT. HUBBELL 4301 Cheyenne Dr. Archdale, N.C. 27263 - HINGE Hubbell/Industrial Controls, Inc. Radio Receiver REMOTE 4.50 + HINGE MH SERIES RECEIVER MANUAL V Supply Voltage ............................ AC: 108–132V ac, 50/60 Hz. DC: 175–350 V dc Internal Power Requirements ........... +11.9–13.1V dc, 0.2 A & +4.5–5.5V dc, 2 A max Operating Temperature .................. –22°F (–30°C) to 140°F (+60°C) HINGE A2 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 14.00 3.00 Control Section Single board computer consisting of 80C31BH controller, 64k EPROM, EPLD containing circuits for message synchronizing, and processor watchdog 31.110 AC Compact Style Weight — ?? AC Output Section (Triac modules) Panel mounted mother-board to accommodate up to 24 triac ac input or output modules 3.25 1.25 4.25 12.00 0.44 DIA. 30.00 24.00 AC/DC Output Section (Electro-mechanical relays) 3.00 Panel mounted mother-board to accommodate 4 plug-in relay boards, each with 6 output relays, for a maximum of 24 ac output relays and 12 sense inputs UP SCROLL DOWN 4.50 H H S5 S6 WBA4406 WBA4493 WBA4493 WBA4493 WBA4493 S4 S7 H S8 S9 S8 S9 H S7 S10 WBA4493 H S6 H H S10 +6 8-32 8-32 8-32 8-32 8-32 8-32 - +12 MODEL NO. 012012 4301 Cheyenne Drive, Archdale, N.C. 27263 V 250 VDC PT.0012012-302 SER. REMOTE MICRO-CONTROL CRANE RECEIVER CABINET RUN ST A1 JK MH A1 A1 2AH A1 LT A1 A1 13 23 33 43 13 23 33 43 13 23 33 43 13 23 33 43 13 23 33 43 13 23 33 43 14 24 34 44 14 24 34 44 14 24 34 44 14 24 34 44 14 24 34 44 14 24 34 44 A2 A2 A2 A2 A2 A2 31.25 S3 S5 WBA4493 WBA4493 H H 30.00 S2 S4 H WBA4493 WBA4493 H S1 S3 H WBA4493 H SO H WBA4493 S2 WBA4493 WBA4493 A1-J3 H S1 WBA4493 A1-J4 H SO INSERT SYS. ENG. DOCUMENTS WBA4493 WBA4493 CODES Indicators ................................... LED on each output Feedback Sensing ........................ opto-isolated input from: MAIN CONTACTOR; UP, DOWN, FORWARD, REVERSE relay outputs Modules ..................................... Industry standard or equivalent design, solid state Output Rating .............................. 115/230V ac, 50/60 Hz, 2A resistive; 100V ac, 50/60 Hz, 0.5 A dry contact resistive Isolation ..................................... 2500V Indicators ................................... LED on each output Feedback Sensing ........................ opto-isolated input from: MAIN CONTACTOR; UP, DOWN, FORWARD, REVERSE relay outputs Relays ........................................ Standard PC board relays Output Rating .............................. 115/230V ac, 50/60 Hz, 5A resistive; 12/24V dc, 5A resistive Isolation ..................................... 5000V AC/DC Output Section (PNP open collector outputs) 24.00 3.00 31.120 DC Compact Style Weight — ?? Panel mounted mother-board to accommodate 4 plug-in boards, each with 6 output transistors, for a maximum of 24 dc outputs and 12 sense inputs Indicators ................................... LED on each output Feedback Sensing ........................ opto-isolated input from: MAIN CONTACTOR; UP, DOWN, FORWARD, REVERSE relay outputs Output Rating .............................. 12V dc, 100mA Isolation ..................................... 5000V AC/DC Output Section (Stepped analog outputs) Panel mounted mother-board to accommodate 4 plug-in boards, each with 1 analog output. Indicators ................................... LED on each of 8 levels Output Rating .............................. 0–10V dc, 20mA, in 8 steps Isolation ..................................... 5000V AC/DC Output Section (Stepless analog outputs) Panel mounted PC board with 4 analog outputs, and 4 sense inputs Indicators ................................... LED on each output Output Rating .............................. ±10V dc, ±20V dc, into a 600 ohm load Isolation ..................................... 5000V 250V DC Output Section Dual solid state relay PC boards in 10 slot card cage allowing for up to 20 outputs. (WBA 4493) HUBBELL Hubbell Industrial Controls, Inc. a subsidiary of Hubbell Incorporated JPS-100-1M © 2000 Printed in U.S.A. 50 Edwards Street Madison, Ohio 44057 (440) 428-1161 Fax (440) 428-7635 4301 Cheyenne Drive Archdale, NC 27263 (336) 434-2800 Fax (336) 434-2801 Type .......................................... Oscillator driven transformer coupled Indicators ................................... Red: output activated, Green: output on (15 ma min. current flowing in output circuit) Output Voltage ............................ 150–350V dc Reverse Polarity Protection .............. 2kV transient voltage protected, 40 µJ Input Voltage ............................... 4.5–6.5V dc, active high Load .......................................... 1.8A, 250V dc, inductive Arc Suppression ........................... 700V (built-in), 40 J Isolation ..................................... 4000V Feedback Sensing ........................ opto-isolated input from: MAIN CONTACTOR; UP, DOWN, FORWARD, REVERSE 250V DC Input Board Dual input 250V dc voltage sensing PC board (occupies 1 slot in card cage) (WBA 4306) Indicator ..................................... Green: on (250V input present) Input .......................................... 250V nominal Isolation ..................................... 3.5kV into, out, & between sections Output ....................................... Opto-isolated; active low Hubbell Industrial Control Solutions http://www.hubbell-icd.com/radiocontrols/