REVISIONS
NOTES:
1. 1-SIDED INSTRUCTION SHEET
2. PRINT COLOR: BLACK
3. MATERIAL: PER SPEC 4080190
REV.
ECN NO.
2
ITEM A, UPC 40783643454826 WAS
783643454828.
3 ADDED ITEM 600635C
4 REMOVED REFERENCE TO QLD3
AND BX140HL
5 600635B FIXED TYPO FROM “A” TO “B”
4.25"
CATALOG NUMBER
CATALOG NUMBER
ECPLD1R
electriCenter
ACCESSORIES
1" Wide - Padlocking Device
Same As:
INSTALLATION INSTRUCTIONS
BARBS
83643 49636
7
1
Package contains 3 devices.
Same As:
BARBS
Turn off power supplying this
equipment before working inside.
SAFETY INSTRUCTIONS
FIG. 2
Note: This instruction outlines the
recommended installation procedure.
FIG. 1
Hazardous Voltage.
Will cause death,
serious injury or substantial
property damage.
FIG. 2
BARBS
Note: This instruction outlines the
recommended installation procedure.
BARBS
BARBS
1. Turn off and lock off the power supplying this enclosure before
working inside.
2. To install, press the padlocking assembly onto the circuit breaker
(Fig.1). (The barbs on the lock mount will cause this to be a snug
fit).
2. To install, press the padlocking assembly onto the circuit breaker
(Fig.1). (The barbs on the lock mount will cause this to be a snug
fit).
2. To install, press the padlocking assembly onto the circuit breaker
(Fig.1). (The barbs on the lock mount will cause this to be a snug
fit).
3. The circuit breaker can be locked in the "OFF" or "ON" position.
Once the padlocking assembly is installed, the lock plate must be
3. The circuit breaker can be locked in the "OFF" or "ON" position.
Once the padlocking assembly is installed, the lock plate must be
3. The circuit breaker can be locked in the "OFF" or "ON" position.
Once the padlocking assembly is installed, the lock plate must be
600635A Rev.X
600635B Rev.X
Norcross, Georgia U.S.A.
Assembled in Mexico
Siemens Industry, Inc.
PART NO. 600635A
Norcross, Georgia U.S.A.
Siemens Industry, Inc.
WHERE “X”
DENOTES
REVISION
LEVEL
600635C Rev.X
© 2007 Copyright Siemens Industry, Inc.
Assembled in Mexico
PART NO. 600635B
WHERE “X” DENOTES
REVISION LEVEL
R. Martinez
4
1. Turn off and lock off the power supplying this enclosure before
working inside.
Siemens Industry, Inc.
02/16/10
Package contains 3 devices.
DANGER
BARBS
40892 09060
0
1. Turn off and lock off the power supplying this enclosure before
working inside.
© 2007 Copyright Siemens Industry, Inc.
Rm RM
ACCESSORIES
ECPLD1, PLD1
FIG. 1
Turn off power supplying this
equipment before working inside.
SAFETY INSTRUCTIONS
FIG. 2
Note: This instruction outlines the
recommended installation procedure.
10-010J1
6/8/09
INSTALLATION INSTRUCTIONS
Hazardous Voltage.
Will cause death,
serious injury or substantial
property damage.
5.50"
Turn off power supplying this
equipment before working inside.
RS
RS
This kit fits SIEMENS and MURRAY breaker types:
ECPLD1, PLD1
DANGER
FIG. 1
11/20/08
1/28/09
electriCenter
BAF, BAFH, BE, BLE, BLEH, BLF, BLHF,
BQ, BQHF, BQAF, BQAFH, BQH, BQP, HBQ,
HQP, MH-T, MP-AT, MP-ET, MP-GT, MP-HAT,
MP-HET, MP-HGT, MP-HT, MP-MT, MP-T,
QAF, QAFH, QE, QEH, QG, QP, QPF, QPH,
QPHF, QT.
INSTALLATION INSTRUCTIONS
Hazardous Voltage.
Will cause death,
serious injury or substantial
property damage.
08-204NC
09-016NC
1" Wide - Padlocking Device
This kit fits SIEMENS and MURRAY breaker types:
40783643454826
SAFETY INSTRUCTIONS
ACCESSORIES
BAF, BAFH, BE, BLE, BLEH, BLF, BLHF, BQ,
BQHF, BQAF, BQAFH, BQH, BQP, HBQ, HQP,
MH-T, MP-AT, MP-ET, MP-GT, MP-HAT, MP-HET,
MP-HGT, MP-HT, MP-MT, MP-T, QAF, QAFH,
QE, QEH, QG, QP, QPF, QPH, QPHF, QT.
PLD1
DANGER
ECPLD1P
electriCenter
Package contains 3 devices.
This kit fits SIEMENS and MURRAY breaker types:
OO
CATALOG NUMBER
1" Wide - Padlocking Device
BAF, BAFH, BE, BLE, BLEH, BLF, BLHF,
BQ, BQHF, BQAF, BQAFH, BQH, BQP, HBQ,
HQP, MH-T, MP-AT, MP-ET, MP-GT, MP-HAT,
MP-HET, MP-HGT, MP-HT, MP-MT, MP-T,
QAF, QAFH, QE, QEH, QG, QP, QPF, QPH,
QPHF, QT.
02/12/08
4.25"
5.50"
ECPLD1
APPROVED
5.50"
4.25"
DATE
07-243J1
09-057J1
CHANGED "SIEMENS ENERGY & AUTOMATION" FOR "SIEMENS INDUSTRY, INC.
CHANGED "CIRCUIT PROTECTION & CONTROL DIVISION" FOR "SIEMENS BUILDING
TECHNOLOGIES" CHANGED "ALPHARETTA"
FOR "NORCROSS"”
6
Same As:
DESCRIPTION
Norcross, Georgia U.S.A.
Assembled in Mexico
PART NO. 600635C
CONFIDENTIAL- PROPERTY OF Siemens Industry, Inc.
WHERE “X” DENOTES
REVISION LEVEL
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
DO NOT SCALE DRAWING
Siemens Industry, Inc.
TOLERANCES:
.XX ±
.12
INSTRUCTION SHEET
.XXX ±
ANGULAR ±
THIRD ANGLE PROJ.
DWN
O.RANGELDATE
CHKB.GARCIA DATE
APVD
B.GARCIA DATE
12/03/03
12/04/03
12/05/03
SIZE
FSCM NO.
SCALE
1:1
B
DWG NO.
CORELDRAW FILE:
REV.
600635
SHEET
1
6
OF
1