IM-010 LEAVE A CLEARANCE OF AT LEAST 12” AROUND THE CONTROLLER BOX TO ALLOW THE COVER TO BE REMOVED FOR MAINTENANCE. VOLTAGE SELECTOR 115/230 VAC NOTES: INSTALLATION OF A GOOD QUALITY ALARM SYSTEM IS STRONGLY SUGGESTED TO WARN OF POWER FAILURES AND HIGH/LOW TEMPERATURES. 230V CONNECTION FOR COMMUNICATIONS BOARD COMLINK-1 CARD 4 POT. + 0-10V IN GND + GND ALARM NC C NO L1 L2/N DO NOT GROUND THE SHIELD ON THE POTENTIOMETER WIRE. ISOLATE THE WIRE FROM ALL HIGH VOLTAGE SOURCES. { REFER TO THE DIAGRAMS BELOW TO CONNECT THE POTENTIOMETER { GND L2 ( N ) L1 ALARM SUPPLY REFER TO THE DIAGRAMS BELOW TO CONNECT THE ACTUATOR 0-10V0-10V+ to MODULE 3 terminal of the ventilation controller to MODULE 2 terminal of the ventilation controller 0-10V ALARM NC C NO CONNECT THE PROPER TERMINALS (0-10V OR MODULE) DEPENDING ON THE CHOSEN COMMUNICATION METHOD. 1 L1 L2/N 2 3 4 POT. + 0-10V IN GND + GND ACTUATOR ALARM NC C NO IN OPN CLO RET IT IS IMPORTANT TO CONNECT THE WINCH RETURN TERMINAL TO THE ACTUATOR L1 IT IS IMPORTANT TO CONNECT THE WINCH RETURN TERMINAL TO THE ACTUATOR { L1 WHITE (N) GREEN GND THE RESISTANCE INCREASES ON “GND” and “IN” WHEN OPENING N 18AWG SHIELDED CABLES ACTUATOR POWER SUPPLY 115 VAC { ACTUATOR POWER SUPPLY 115 VAC RED BLACK { POTENTIOMETER THE RESISTANCE INCREASES ON “GND” and “IN” WHEN OPENING L1 L2/N GND YELLOW 18AWG SHIELDED CABLES Vic Jack Actuator with potentiometer (1, 5 or 10 Kohms, 10 Turns) To communication (MODULE) terminals 1 of a ventilation controller . MODULES ACTUATOR IN OPN CLO RET OPEN = RED IN GND + GND OR WHITE POT. + { 1 COMMUNICATION BETWEEN THE IM-010V AND THE VENTILATION CONTROLLER CAN EITHER BE ESTABLISHED WITH A 0-10V SIGNAL OR BY USING THE COMMUNICATION BUS. To 0-10V output of the ventilation controller 1 . CLOSE = BLACK 4 RED 3 BLACK 2 YELLOW (WIPER) MODULES { CONTROLLER POWER SUPPLY 230 VAC (115VAC) VON WEISE V-76-115 ACTUATOR- AC MOTOR VIC JACK ACTUATOR- AC MOTOR 1 PROVIDE A SURGE PROTECTION (INCLUDING LIGHTNING PROTECTION) FROM THE POWER SUPPLY TO THE CONTROLLER AND FROM THE CONTROL TO THE SENSORS. CONSULT A CERTIFIED ELECTRICIAN IF REQUIRED. ACTUATOR IN OPN CLO RET OPEN 3 CLOSE 2 ORANGE MODULES 1 BLUE (WIPER) DO NOT DRILL THE SIDE OF THE UNIT CONTROL. USE AVAILABLE KNOCKOUTS AT THE BOTTOM OF THE UNIT. Von Weise Actuator V-76-115 115 VAC with potentiometer (1, 5 or 10 Kohms, 10 Turns) WIRING DIAGRAM IM-010 #891-00081 Rev.01 WIRING DIAGRAM #891-00081 IM-010 Rev.01 WHITE ORANGE 3 4 + 4 + THE RESISTANCE INCREASES ON “GND” and “IN” WHEN OPENING 0-10V THE RESISTANCE INCREASES ON “GND” and “IN” WHEN OPENING ACTUATOR POWER SUPPLY 115 VAC { ACTUATOR IN OPN CLO RET ALARM IN OPN CLO RET NC C NO 18AWG SHIELDED CABLES { L1 N GND L1 L2/N ACTUATOR N { GND + + G FILTER ACTUATOR - G ACTUATOR POWER SUPPLY 230 VAC (115 VAC) ACTUATOR L1 L2 ( N ) 18 TO 36 VDC TRANSFORMER L - FILTER 18 TO 36 VDC TRANSFORMER N IT IS IMPORTANT TO CONNECT THE WINCH RETURN TERMINAL TO THE ACTUATOR L1 L2/N IT IS IMPORTANT TO CONNECT THE WINCH RETURN TERMINAL WITH THE ACTUATOR L1 L2/N L1 N L IN OPN CLO RET GND ACTUATOR ACTUATOR POWER SUPPLY 115 VAC ALARM 18AWG SHIELDED CABLES ALARM NC C NO 18AWG SHIELDED CABLES NC C NO IN GND + GND POT. 0-10V IN GND + GND POT. 0-10V + IN GND + GND POT. 4 POTENTIOMETER (1, 5 or 10 Kohms, 10 Turns) 3 POTENTIOMETER (1, 5 or 10 Kohms, 10 Turns) 2 2 WIPER MODULES 1 1 MODULES Von Weise actuator V-76-30 36VDC Motor with potentiometer (1, 5 OR 10 Kohms, 10 Turns) { BLUE (WIPER) BLACK RED 3 THE RESISTANCE INCREASES ON “GND” and “IN” WHEN OPENING WIPER OPEN 2 OPEN CLOSE MODULES CLOSE OPEN +18VAC 1 +18VAC POTENTIOMETER VON WEISE V-76-30 ACTUATOR - DC MOTOR -18VAC CLOSE -18VAC