Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Interface technology in modular housing DIN rail devices, IM series Solonoid driver, 1‑channel Features ▪▪ ATEX, IECEx, UL, CFMUS TR CU, NEPSI, INMETRO U1 +1 24 V (U1) 15 V (U2) U2 1 +2 11+ 1 YE –3 12 – 1 19...30 VDC <3W ▪▪ Installation in zone 2 ▪▪ Voltage input max. 30 VDC ▪▪ Voltage outuput 15 VDC resp. 24 VDC ▪▪ Output current ≤ 40 mA ▪▪ Switching frequency ≤ 500 Hz ▪▪ SIL3 ▪▪ Removable terminal blocks ▪▪ Galvanic isolation between input cir‑ cuits and output circuits explosive atmospheresvoltage and are adapted to the valves of The 1‑channel solonoid driverpotentially IM72‑11EX/L provides intrinsically safe caused by dust or gas, provided they different manufacturers (see output limited power at the output. This enables comply with the applicable regulations. curve on next page). them to be used directly for supplying loads in the Ex area. Typical applications are the control of Exi The loads are actuated by applying the pilot valves as well as the supply of d is‑ operating voltage. Within the area of applicability of the E u‑ plays and transmitters. The output v alues ropean directive 94/9/EC (ATEX) it is per‑ of the two connections U1 and U2 per A yellow LED indicates the switching mitted to operate connected loads in channel differ in terms of their n o-load state of the associated output. Zone 2: Do not disconnect when live! IM72-11Ex/L 426 Hans Turck GmbH & Co. KG ■ Tel. +49 208 49 52-0 ■ Fax +49 208 49 52-264 Interface technology in modular housing DIN rail devices, IM series Technical data IM72-11EX/L 7520703 Power supply Nominal voltage Power consumption 24 VDC loop-powered ≤ 1.5 W Inputs 0-signal 1-signal Voltage input Current input Input delay 0…5 VDC 19…30 VDC max. 30 VDC 45 mA ≤ 2 ms Outputs Output circuits Output current Output voltage Output voltage Output curve Application area Protection type Max. values: Max.output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [nF] intrinsically safe acc. to EN 60079 40 mA U1=24 V U2=15 V Response characteristic Limit frequency ≤ 500 Hz Approvals and declarations Ex approval acc. to conformity certificate Device designation Max. values: Max. output voltage Uo Max. output current Io Max. output power Po Rated voltage Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co EEx ia Lo [mH] Co [nF] IIC 0.68 62 0.5 70 Max. values: Max. output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co EEx ia Lo [mH] Co [µF] IIC 1.2 0.13 0.5 0.15 Ex approval acc. to conformity certificate TÜV 05 ATEX 2846 X É II (1) GD [EEx ia] IIC Terminal connection: 1+3 ≤ 27 V ≤ 96 mA ≤ 678 mW 250 V Trapezoidal negligibly small IIB 13 260 2 300 Terminal connection: 2+3 ≤ 17.6 V ≤ 96 mA ≤ 678 mW trapezoidal negligibly small IIB 13.0 0.47 0.5 130 Max. values: Max.output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [µF] IIC 0.68 120 IIC 1.2 0.37 0.5 0.42 II 3 G Ex nA [nL] IIC/IIB T4 Terminal connection: 1+3 ≤ 27 V ≤ 96 mA ≤ 678 mW trapezoidal negligibly small IIB 13 570 2 620 Terminal connection: 2+3 ≤ 17.6 V ≤ 96 mA ≤ 678 mW trapezoidal negligibly small IIB 13 1 2.0 2.1 Declaration SIL 3 acc. to EXIDA FMEDA Indication Switching state yellow Environmental Conditions Ambient temperature Storage temperature Test voltage -25…+70 °C -40…+80 °C 2.5 kV Mechanical data Tightening torque Electrical connection Terminal cross-section Housing material Mounting instruction Protection class Flammability class acc. to UL 94 Dimensions Approval | Certification 0.5 Nm 4 x 3‑pin removable terminal blocks, reverse polarity protected, screw connection 1 x 2.5 mm2 / 2 x 1.5 mm2 Polycarbonate/ABS for DIN rail / panel IP20 V-0 18 x 104 x 110 mm ATEX, IECEx, UL, cFMus, TR CU, NEPSI, INMETRO 2.0 1.1 TÜV 06 ATEX 553388 X [email protected] ■ www.turck.com ■ Edition I/2014 427 Interface technology Type Ident no. Interface technology in modular housing DIN rail devices, IM series Solonoid driver, 2‑channel Features ▪▪ ATEX, IECEx, UL, CFMUS TR CU, NEPSI, INMETRO U1 +1 U2 1 +2 11 + 1 YE –3 24 V (U1) 15 V (U2) 12 – 19...30 VDC <3W U1 +4 U2 2 +5 1 8+ 2 YE –6 9– 2 ▪▪ Installation in zone 2 ▪▪ Voltage input max. 30 VDC ▪▪ Voltage outuput 15 VDC resp. 24 VDC ▪▪ Output current ≤ 40 mA ▪▪ Switching frequency ≤ 500 Hz ▪▪ SIL3 ▪▪ Removable terminal blocks ▪▪ Galvanic isolation between input and output circuits IM72‑ The 1‑channel solonoid driver 22EX/L provides intrinsically safe limited power at the output. This enables them to be used directly for supplying loads in the Ex area. potentially explosive atmospheresvoltage and are adapted to the valves of caused by dust or gas, provided they different manufacturers (see output comply with the applicable regulations. curve on next page). Typical applications are the control of Exi pilot valves as well as the supply of d is‑ Within the area of applicability of the E u‑ plays and transmitters. The output v alues ropean directive 94/9/EC (ATEX) it is per‑ of the two connections U1 and U2 per mitted to operate connected loads in channel differ in terms of their n o-load The loads are actuated by applying the operating voltage. A yellow LED indicates the switching state of the associated output. 428 Hans Turck GmbH & Co. KG ■ Tel. +49 208 49 52-0 ■ Fax +49 208 49 52-264 Interface technology in modular housing DIN rail devices, IM series Technical data IM72-22EX/L 7520702 Power supply Nominal voltage Power consumption 24 VDC loop-powered ≤ 2.2 W Inputs 0-signal 1-signal Voltage input Current input Input delay 0…5 VDC 19…30 VDC max. 30 VDC 45 mA ≤ 2 ms Outputs Output circuits Output current Output voltage Output voltage Output curve Application area Protection type Max. values: Max.output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [nF] intrinsically safe acc. to EN 60079 40 mA U1=24 V U2=15 V Response characteristic Limit frequency ≤ 500 Hz Approvals and declarations Ex approval acc. to conformity certificate Device designation Max. values: Max. output voltage Uo Max. output current Io Max. output power Po Rated voltage Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co EEx ia Lo [mH] Co [nF] IIC 0.68 62 0.5 70 Max. values: Max. output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co EEx ia Lo [mH] Co [µF] IIC 1.2 0.13 0.5 0.15 Ex approval acc. to conformity certificate TÜV 05 ATEX 2846 X É II (1) GD [EEx ia] IIC Terminal connection: 1+3 / 4+6 ≤ 27 V ≤ 96 mA ≤ 678 mW 250 V Trapezoidal negligibly small IIB 13 260 2 300 Terminal connection: 2+3 / 5+6 ≤ 17.6 V ≤ 96 mA ≤ 678 mW trapezoidal negligibly small IIB 13.0 0.47 0.5 130 Max. values: Max.output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [µF] IIC 0.68 120 IIC 1.2 0.37 0.5 0.42 II 3 G Ex nA [nL] IIC/IIB T4 Terminal connection: 1+3 / 4+6 ≤ 27 V ≤ 96 mA ≤ 678 mW trapezoidal negligibly small IIB 13 570 2 620 Terminal connection: 2+3 / 5+6 ≤ 17.6 V ≤ 96 mA ≤ 678 mW trapezoidal negligibly small IIB 13 1 2.0 2.1 Declaration SIL 3 acc. to EXIDA FMEDA Indication Switching state yellow Environmental Conditions Ambient temperature Storage temperature Test voltage -25…+70 °C -40…+80 °C 2.5 kV Mechanical data Tightening torque Electrical connection Terminal cross-section Housing material Mounting instruction Protection class Flammability class acc. to UL 94 Dimensions Approval | Certification 0.5 Nm 4 x 3‑pin removable terminal blocks, reverse polarity protected, screw connection 1 x 2.5 mm2 / 2 x 1.5 mm2 Polycarbonate/ABS for DIN rail / panel IP20 V-0 18 x 104 x 110 mm ATEX, IECEx, UL, cFMus, TR CU, NEPSI, INMETRO 2.0 1.1 TÜV 06 ATEX 553388 X [email protected] ■ www.turck.com ■ Edition I/2014 429 Interface technology Type Ident no. Interface Technology in Modular Housing DIN rail mounted devices of the IME series Solonoid driver, 1‑channel Features ▪▪ ATEX, IECEx, TR CU, NEPSI ▪▪ Installation in zone 2 ▪▪ Solonoid driver (intrinsically safe pow‑ er source), 1‑channel +6 U1: 24 VDC U2: 15 VDC 1 +5 U1 U2 8+ 1 YE –4 7– 1 24 VDC <3W ▪▪ 2 output values selectable per channel ▪▪ LED status indication ▪▪ Complete galvanic isolation The 1‑channel solonoid driver IME-DO11Ex/L provides limited current and volt‑ age at the intrinsically safe output. This enables them to be used d irectly for sup‑ plying loads in the Ex area. potentially explosive atmospheresterms of their no-load voltage (see out‑ caused by dust or gas, provided they put curve on next page). They are adapt‑ comply with the applicable regulations. ed to the valves of different m anufactur‑ Typical applications are the control of ers. The loads are actuated by applying Ex i pilot valves as well as the supply of the operating voltage. displays and transmitters. Within the area of applicability of the E u‑ A yellow LED indicates the switching ropean directive 94/9/EC (ATEX) it is per‑ The output values of the two connec‑ state of the associated output. mitted to operate connected loads in tions U1 and U2 per channel differ in 458 Hans Turck GmbH & Co. KG ■ Tel. +49 208 49 52-0 ■ Fax +49 208 49 52-264 Interface Technology in Modular Housing DIN rail mounted devices of the IME series Technical data IME-DO-11EX/L 7541196 Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Power supply Nominal voltage Power consumption 24 VDC loop-powered ≤ 1.5 W Inputs 0-signal 1-signal Voltage input Current input Input delay 0…5 VDC 20…30 VDC max. 30 VDC 45 mA ≤ 0.4 ms Outputs Output current Output voltage Output voltage Output curve Ex nL Lo [mH] Co [µF] Ex nL Lo [mH] Co [µF] Ex ia Lo [mH] Co [µF] IIC 0.68 0.067 0.5 0.076 Max. output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex ia Lo [mH] Co [µF] IIC 1.2 0.13 0.5 0.15 Ex approval acc. to conformity certificate Application area Protection type Characteristic É II (1) GD [Ex ia] IIC/IIB ≤ 25.4 V ≤ 96 mA ≤ 678 mW 250 V Trapezoidal negligibly small IIB 13.0 0.31 0.5 0.91 trapezoidal negligibly small IIB 5.0 1.6 1.0 2.5 SIL 3 acc. to EXIDA FMEDA Indication Switching state yellow Mechanical data Electrical connection TÜV 06 ATEX 2977 X 0.5 0.42 IIB 5.0 0.75 Declaration ≤ 500 Hz Approvals and declarations Ex approval acc. to conformity certificate Device designation Max. output voltage Uo Max. output current Io Max. output power Po Rated voltage Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co IIC 2.0 0.3 Environmental Conditions Ambient temperature Storage temperature Test voltage MTTF 0.5 0.14 Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co 40 mA U1=24 V U2=15 V Response characteristic Limit frequency IIC 1.0 0.11 negligibly small -25…+70 °C -40…+80 °C 2.5 kV 363 years acc. to SN 29500 (Ed. 99) 40 °C Terminal cross-section Housing material Mounting instruction Protection class Flammability class acc. to UL 94 Dimensions Spring terminal made of Beryllium- Bronze 1.5 mm2 Polycarbonate/ABS for DIN rail IP20 V-0 18 x 112 x 110 mm Approval | Certification ATEX, IECEx, TR CU, NEPSI Interface technology Type Ident no. 2.0 0.34 ≤ 17.6 V ≤ 96 mA ≤ 678 mW Trapezoidal negligibly small IIB 13.0 0.47 2.0 1.1 TÜV 06 ATEX 2979 X II 3 G Ex nA [nL] IIC / IIB T4 trapezoidal [email protected] ■ www.turck.com ■ Edition I/2014 459 Interface Technology in Modular Housing DIN rail mounted devices of the IME series Solonoid driver, 2‑channel Features +6 1 U1: 24 VDC U2: 15 VDC 2 +5 U1 U2 +2 8+ 1 YE –4 +3 ▪▪ ATEX, IECEx, TR CU, NEPSI ▪▪ Installation in zone 2 ▪▪ Solonoid driver, 2‑channel, (intrinsical‑ 7– 24 VDC <3W U1 U2 10 + 2 YE –1 1 9– ly safe power source) ▪▪ 2 output values selectable per channel ▪▪ LED status indication ▪▪ Complete galvanic isolation 2 The 2‑channel solonoid driver IME-DO22Ex/L provides limited current and volt‑ age at the intrinsically safe output. This enables them to be used d irectly for sup‑ plying loads in the Ex area. potentially explosive atmospheresterms of their no-load voltage (see out‑ caused by dust or gas, provided they put curve on next page). They are adapt‑ comply with the applicable regulations. ed to the valves of different m anufactur‑ Typical applications are the control of Ex ers. The loads are actuated by applying i pilot valves as well as the supply of dis‑ the operating voltage. plays and transmitters. Within the area of applicability of the E u‑ A yellow LED indicates the switching ropean directive 94/9/EC (ATEX) it is per‑ The output values of the two connec‑ state of the associated output. mitted to operate connected loads in tions U1 and U2 per channel differ in 460 Hans Turck GmbH & Co. KG ■ Tel. +49 208 49 52-0 ■ Fax +49 208 49 52-264 Interface Technology in Modular Housing DIN rail mounted devices of the IME series Technical data IME-DO-22EX/L 7541195 Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Power supply Nominal voltage Power consumption 24 VDC loop-powered ≤ 3 W Inputs 0-signal 1-signal Voltage input Input delay 0…5 VDC 20…30 VDC max. 30 VDC ≤ 0.4 ms Outputs Output current Output voltage Output voltage Output curve Ex nL Lo [mH] Co [µF] 40 mA U1=24 V U2=15 V Response characteristic Limit frequency Ex ia Lo [mH] Co [µF] IIC 0.68 0.067 0.5 0.076 Max. output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex ia Lo [mH] Co [µF] IIC 1.2 0.13 0.5 0.15 Ex approval acc. to conformity certificate Application area Protection type Characteristic TÜV 06 ATEX 2977 X É II (1) GD [Ex ia] IIC/IIB ≤ 25.4 V ≤ 96 mA ≤ 678 mW 250 V Trapezoidal negligibly small IIB 13.0 0.31 IIC 2.0 0.3 0.5 0.42 IIB 5.0 0.75 0.5 0.91 trapezoidal negligibly small IIB 5.0 1.6 1.0 2.5 Declaration SIL 3 acc. to EXIDA FMEDA Indication Switching state yellow Environmental Conditions Ambient temperature Storage temperature Test voltage MTTF Mechanical data Electrical connection ≤ 500 Hz Approvals and declarations Ex approval acc. to conformity certificate Device designation Max. output voltage Uo Max. output current Io Max. output power Po Rated voltage Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co 0.5 0.14 Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [µF] IIC 1.0 0.11 negligibly small -25…+70 °C -40…+80 °C 2.5 kV 363 years acc. to SN 29500 (Ed. 99) 40 °C Terminal cross-section Housing material Mounting instruction Protection class Flammability class acc. to UL 94 Dimensions Spring terminal made of Beryllium- Bronze 1.5 mm2 / 0.75 mm2 с flexible Polycarbonate/ABS for DIN rail IP20 V-0 18 x 112 x 110 mm Approval | Certification ATEX, IECEx, TR CU, NEPSI Interface technology Type Ident no. 2.0 0.34 ≤ 17.6 V ≤ 96 mA ≤ 678 mW Trapezoidal negligibly small IIB 13.0 0.47 2.0 1.1 TÜV 06 ATEX 2979 X II 3 G Ex nA [nL] IIC / IIB T4 trapezoidal [email protected] ■ www.turck.com ■ Edition I/2014 461 Distributed interface modules in IP67 housing For direct field installation, IMC series Solonoid driver, 1‑channel Features ▪▪ ATEX, IECEx, TR CU ▪▪ Installation in zone 2/22 ▪▪ Valve control module with M12 x 1 connectors, 1‑channel The device must be protected against mechanical load on connector and housing when mounted in zone 2 or 22. For this, use the TURCK cover plate IMC-SG (ident no. 7560016). Zone 2/22: Do not disconnect, when live! IMC-DO-11Ex/L The device is loop-powered. External power supply is not required. Pin assignment female M12 (intrinsically safe end) 2 2 3 490 Typical applications are the control of Ex i pilot valves and pilot lights as well as the supply of transmitters. Pin assignment male M12 The 1‑channel solonoid driver IMC-DO11Ex/L features an intrinsically safe output circuit. The device can be m ounted in zone 2. ▪▪ Complete galvanic isolation ▪▪ Protection class IP67 4 1 1 5 5 3 4 Hans Turck GmbH & Co. KG ■ Tel. +49 208 49 52-0 ■ Fax +49 208 49 52-264 Distributed interface modules in IP67 housing For direct field installation, IMC series Technical data IMC-DO-11EX/L 7560008 Power supply Nominal voltage Power consumption 24 VDC loop-powered ≤ 1.3 W Inputs 0-signal 1-signal Voltage input Current input Input delay Max. values: Max.output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [nF] 0…5 VDC 20…30 VDC max. 30 VDC 45 mA ≤ 1 ms Outputs Output circuits Output current Output voltage Output curve intrinsically safe acc. to EN 60079 40 mA 24 V Response characteristic Limit frequency Measuring accuracy ≤ 500 Hz ≤ 0.1 % of full scale Approvals and declarations Ex approval acc. to conformity certificate Device designation Max. values: Max. output voltage Uo Max. output current Io Max. output power Po Rated voltage Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex ia Lo [mH] Co [nF] IIC 0.75 60 0.5 70 Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [nF] IIC 4.0 74 0.5 130 Ex approval acc. to conformity certificate Application area Protection type TÜV 07 ATEX 553265 É II (1) GD [Ex ia] IIC/IIB M12 female connection: 1+3 ≤ 27 V ≤ 95 mA ≤ 674 mW 250 V Trapezoidal negligibly small IIB 2 310 IIC 4.0 74 0.5 130 M12 female connection: 1+3 ≤ 27 V ≤ 95 mA ≤ 674 mW trapezoidal negligibly small IIB 20 490 5 630 max.Output voltage Uo max. Output current Io max. Output power Po Approval ≤ 27 V ≤ 95 mA ≤ 674 mW SIL3 acc. to EXIDA FMEDA Indication Switching state yellow Environmental Conditions Ambient temperature Storage temperature Test voltage MTTF -25…+70 °C -40…+80 °C 2.5 kV 326 years acc. to SN 29500 (Ed. 99) 40 °C Mechanical data Tightening torque Electrical connection Housing material Mounting instruction Protection class Dimensions 3.5 Nm M12 flange connection Polycarbonate/ABS for panel IP67 32 x 100 x 25 mm Approval | Certification ATEX, IECEx, TR CU Interface technology Type Ident no. 0.5 450 Trapezoidal negligibly small IIB 20 490 5 630 TÜV 07 ATEX 553647 X II 3G, II 3D Ex nA [nL] IIC/IIB T4 or rather Ex tD A22 IP67 T86 °C [email protected] ■ www.turck.com ■ Edition I/2014 491 Distributed interface modules in IP67 housing For direct field installation, IMC series Solonoid driver, 1‑channel Features ▪▪ ATEX, IECEx, TR CU ▪▪ Installation in zone 2/22 ▪▪ Valve control module with M12 x 1 connectors, 1‑channel The device must be protected against mechanical load on connector and housing when mounted in zone 2 or 22. For this, use the TURCK cover plate IMC-SG (ident no. 7560016). Zone 2/22: Do not disconnect, when live! IMC-DO-11Ex/L The device is loop-powered. External power supply is not required. Pin assignment female M12 (intrinsically safe end) 2 2 3 490 Typical applications are the control of Ex i pilot valves and pilot lights as well as the supply of transmitters. Pin assignment male M12 The 1‑channel solonoid driver IMC-DO11Ex/L features an intrinsically safe output circuit. The device can be m ounted in zone 2. ▪▪ Complete galvanic isolation ▪▪ Protection class IP67 4 1 1 5 5 3 4 Hans Turck GmbH & Co. KG ■ Tel. +49 208 49 52-0 ■ Fax +49 208 49 52-264 Distributed interface modules in IP67 housing For direct field installation, IMC series Technical data IMC-DO-11EX/L 7560008 Power supply Nominal voltage Power consumption 24 VDC loop-powered ≤ 1.3 W Inputs 0-signal 1-signal Voltage input Current input Input delay Max. values: Max.output voltage Uo Max. output current Io Max. output power Po Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [nF] 0…5 VDC 20…30 VDC max. 30 VDC 45 mA ≤ 1 ms Outputs Output circuits Output current Output voltage Output curve intrinsically safe acc. to EN 60079 40 mA 24 V Response characteristic Limit frequency Measuring accuracy ≤ 500 Hz ≤ 0.1 % of full scale Approvals and declarations Ex approval acc. to conformity certificate Device designation Max. values: Max. output voltage Uo Max. output current Io Max. output power Po Rated voltage Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex ia Lo [mH] Co [nF] IIC 0.75 60 0.5 70 Characteristic Internal inductance/capacitance Li/Ci External inductance/capacitance Lo/Co Ex nL Lo [mH] Co [nF] IIC 4.0 74 0.5 130 Ex approval acc. to conformity certificate Application area Protection type TÜV 07 ATEX 553265 É II (1) GD [Ex ia] IIC/IIB M12 female connection: 1+3 ≤ 27 V ≤ 95 mA ≤ 674 mW 250 V Trapezoidal negligibly small IIB 2 310 IIC 4.0 74 0.5 130 M12 female connection: 1+3 ≤ 27 V ≤ 95 mA ≤ 674 mW trapezoidal negligibly small IIB 20 490 5 630 max.Output voltage Uo max. Output current Io max. Output power Po Approval ≤ 27 V ≤ 95 mA ≤ 674 mW SIL3 acc. to EXIDA FMEDA Indication Switching state yellow Environmental Conditions Ambient temperature Storage temperature Test voltage MTTF -25…+70 °C -40…+80 °C 2.5 kV 326 years acc. to SN 29500 (Ed. 99) 40 °C Mechanical data Tightening torque Electrical connection Housing material Mounting instruction Protection class Dimensions 3.5 Nm M12 flange connection Polycarbonate/ABS for panel IP67 32 x 100 x 25 mm Approval | Certification ATEX, IECEx, TR CU Interface technology Type Ident no. 0.5 450 Trapezoidal negligibly small IIB 20 490 5 630 TÜV 07 ATEX 553647 X II 3G, II 3D Ex nA [nL] IIC/IIB T4 or rather Ex tD A22 IP67 T86 °C [email protected] ■ www.turck.com ■ Edition I/2014 491