Download ELK-980 Instructions

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power inverter wikipedia , lookup

Public address system wikipedia , lookup

Islanding wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Ground (electricity) wikipedia , lookup

Stray voltage wikipedia , lookup

Three-phase electric power wikipedia , lookup

Rectifier wikipedia , lookup

Electrification wikipedia , lookup

Electrical substation wikipedia , lookup

Electric power system wikipedia , lookup

Opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power over Ethernet wikipedia , lookup

Audio power wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Relay wikipedia , lookup

Fault tolerance wikipedia , lookup

Power electronics wikipedia , lookup

Power engineering wikipedia , lookup

Voltage optimisation wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Metadyne wikipedia , lookup

Earthing system wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Telecommunications engineering wikipedia , lookup

AC adapter wikipedia , lookup

Protective relay wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
* Try these other fine ELK products *
Magic Module Series
MM443 Magic Module, 4 Input, 4 Output, Programmable
MM447 Automation Controller w/Voice,Caddx Interface
MV480
Recordable Voice Module, 400 Channels
MKHOME1 Home Control Kit for Caddx NX Controls
MK400
Starter Kit, Includes MM443 & MK485
MK485
Programming Kit, MB485, Cables, Software
MK410
X-10® Transceiver Kit, Programmed MM443
iButton™ Access Kit w/ MM443, MA100, MA101
MK420
MA100
iButton™ ‘Touchkey’ Reader & Interface Pack
MA101
iButton™ ‘Touchkeys’,10 pcs w/keyring holders
MA290
Proximity / Wiegand Data Interface to MM443
MB485
Data Bus Interface, RS232 to RS485
MC100
Clock / Calendar Module for MM443
ML8
Link Interface to Caddx NX Controls
MT100
Temperature Sensor Module for MM443
MM220 Magic Module, 2 Input, 2 Output, Programmable
Rust Free Sirens / Speakers
1RT
Speaker & Stainless Steel Enclosure
150RT Siren & Stainless Steel Enclosure
155RT Voice Siren in Stainless Steel Box
Speakers & Sirens
44
Speaker, 30 W,8 Ohm Compact Horn
45
Siren, Compact Horn, 118db
55
Voice Siren, Compact Horn
M120 Siren, Single Tone, 107db, Mini Horn
SP15
Speaker, 15 watt, Small Horn
SP30
Speaker, 30 watt, Horn
SP35
Speaker, 20 watt, Interior
SP40
Speaker, 40 watt, Horn
SS15
Siren, Dual Tone, 110db, Horn
SS30
Siren, Dual Tone, 120db, Horn
SS36
Siren, Dual Tone, 105db, Interior
ECHO™ Sirens & Speakers
73
ECHO Speaker, 20 Watt, Interior
74
ECHO Dual Tone Siren, Interior
75
ECHO Voice Siren, Interior
870
ECHO Speaker, Self Amplified
Siren & Voice Drivers
100
High Performance Siren Driver
110
Voice Siren Driver, English & Spanish
120
Recordable Voice Module and Siren
124
Recordable Voice Module, 4 Channels
Surge Suppressors
950
Surge Suppressor, Phone & Power Line
951
Surge Suppressor, Phone - Single Line
955
Surge Suppressor, Phone - Dual Line
Relay Modules
912
Compact Relay,12 Vdc, SPDT
912B
Heavy Duty Compact Relay,12/24 Vdc, SPDT
924
Sensitive Relay, 12/24 Vdc, DPDT
941
Alarm Output Director
960
Delay Timer Relay, 1 sec. to 60 min.
Power Products
1240
Battery, Lead Acid, 12v, 5Ah
1270
Battery, Lead Acid, 12v, 8Ah
12100 Battery, Lead Acid, 12v, 12Ah
12170 Battery, Lead Acid, 12v, 18Ah
12250 Battery, Lead Acid, 12v, 25Ah
P112
12 Volts DC, 1 Amp Power Supply w/Enclosure
P124
24 Volts DC, 800mA Power Supply w/Enclosure
P1216 12 Volts DC, 1.5 Amp Power Supply
P412
12 Volts DC, 4 Amp Power Supply
P624
Power Supply & Battery Charger
PD9
Power Distribution Module
965
Low Battery Cutoff and Power Switch
TRG1640 Transformer, 16.5VAC @ 40 VA
TRG2440 Transformer, 24VAC @ 40 VA
Accessories
129
Computer Sound Card Interface
800
Audio Amplifier, 10 Watts
900-2 “B” Connectors,Unfilled,500 pcs
902-2 “B” Connectors,Gel filled,500 pcs
980
Telephone Line Fault Monitor
998
Warning Alarm System Decals
999
Double Sided Tape
SL1
Strobe Light, 4 colors available
WK1
Wall Mount Kit for SL1 Strobes
For more information contact your local Distributor or:
ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415
http://www.elkproducts.com
Email: [email protected]
01/03
Telephone Line
Fault Monitor
ELK-980
APPLICATION:
The ELK-980 triggers a relay output upon sensing a dead telephone line. Circuitry monitors
phone line voltage as well as current in order to
protect against false sensing. It installs easily
between the incoming telephone block and the
equipment using standard 8 conductor modular
cables (not supplied).
Telephone Line
Fault Monitor
ELK-980
FEATURES:
• Detects a Faulted Telephone Line.
• Monitors Phone Line Voltage and Current.
• Selectable Time Delay period on the relay.
• Built-in LED displays Status / Fault Memory.
• Unit is Powered by 12 or 24 Volts D.C.
• Provides Form "C" Relay Output on Fault.
• Dual RJ31/38X 8 Position Modular Jacks.
• Lifetime Limited Warranty, call for details.
SPECIFICATIONS:
• Operating Voltage: 12 or 24 Volts D.C.
• Current Draw: 30mA.
• Dimensions: 4.4" x 3.0" x 1.125".
• Relay Contact Rating: 1A @ 250VAC.
• Requires (2) 8 Pin Modular Cables
(not included).
This device complies with Part 68 of the FCC rules. FCC Reg. No.
5K6USA-25252-KX-N Ren No. 0.0B. It has been tested and found
to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC rules. See label on ELK-980 for Canadian DOC
Certification Number.
Features and Specifications subject to change without notice.
828-397-4200 Voice
828-397-4415 Fax
http://www.elkproducts.com
email: [email protected]
PO Box 100 • Hwy. 70W • Hildebran, NC 28637 • USA
Instructions Printed On Inside
INSTALLATION
1. Connect the ELK-980 to the incoming phone jack using a standard 8 wire full modular "male to male" phone cord (J2).
2. Connect the security equipment using a second 8 wire cord (J1). Depending on the equipment, this cord may be identical or
it may have a male plug on one end and spade terminals on the other end. (PHONE CORDS ARE NOT SUPPLIED)
3. Connect two (2) wires from the ELK-980 to 12 Volts D.C. To power from 24 VDC, move Jumper JP3 to the 24V position.
4. Connect two (2) wires from the relay output to the device that is to be activated when a dead phone line is detected.
Option: Power and relay connections can be made using the four (4) extra wires in modular cord J1. This requires a cord
with a male plug on one end and spade terminal wires on the other. This is not possible if the security equipment requires a
male plug ended cord. See FIGURES 1 and 2 below for details on the various jumper options and wiring configurations.
OPERATION
A typical on-hook phone line will measure around 48 volts. The voltage is lower during a call in process (off-hook), however the
telephone instrument will then draw current on the line. The ELK-980 utilizes both telco voltage and current to properly detect a
faulted line while reducing incidents of false detects. The ELK-980 considers the phone line to be faulted whenever the
line voltage falls below 3 volts and the line current draw is less than 18mA.
PHONE LINE OK STATUS LED blinks once per second as line is tested. Relay energized, contacts COM and NC are closed.
PHONE LINE FAULT - STATUS LED steady ON. Relay de-energized, contacts COM and NC are open, COM and NO are closed.
FAULT MEMORY Upon restoral of a phone line fault the LED remains predominantly ON and blinks OFF once every 3
seconds. To reset memory indication, momentarily short (for 2 seconds) the two small pins beside the
STATUS LED. LED should return to 1 blink per second if phone line is OK.
FIGURE 1: USING SCREW TERMINALS AND WIRES FOR POWER AND RELAY
JUMPERS JP2 AND JP4 MUST BE SET AS SHOWN FOR THIS CONFIGURATION
JUMPER JP3: INPUT VOLTAGE
JUMPER JP2: POWER HOOKUP
SET TO "NO" TO
CONNECT POWER
USING POS. & NEG.
SCREW TERMINALS
SECURITY/PHONE
EQUIPMENT
3 & 6 (NOT USED)
2 & 7 (OPTIONAL)
PLUG TAMPER LOOP
RING
TIP
TELCO
R1
T1
AUX
POWER
SET JUMPER ON "B"
THIS CREATES A CLOSED
LOOP ON WIRES 2 & 7 OF J1
AB C
ELK-980
Telephone Line
Fault Module
MALE PLUG MAY
BE REQUIRED WITH
SOME EQUIPMENT
TO J1
A B C
JP4
JUMPER JP1: DELAY AFTER FAULT
JP1
JP2
24V 12V
JP3
YES
NO
WIRE WIRE
NO. COLOR
3 BLACK
6 YELLOW
8 PIN
JACK
OUT
J1
2 ORANGE
7 BLUE
4 RED
5 GREEN
1 SLATE
8 BROWN
J1
8 PIN
JACK
IN
J2
SETS TIME DELAY BEFORE RELAY
OPENS AFTER LINE FAULT
5 MIN
30 SEC
K1
JP5
NEG POS N/O COM N/C
POWER ALARM RELAY
YES
NO
JUMPER JP4: SUPERVISION HOOKUP
THE ELK-980 CAN BE
24V 12V
POWERED FROM A 12V OR
24VDC POWER SUPPLY
30 SEC
K1 RELAY IS ENERGIZED WHILE
PHONE LINE IS GOOD (CLOSED
CIRCUIT: COM TO NC)
RJ31X JACK
D7
(ELK-950 Recommended)
RESET
STATUS
R1
1
2
3
8
7
T1
6
CORD MAY BE
(MALE TO MALE) OR
(MALE TO SPADE)
R
INCOMING
TELCO
LINE
4
J2
NEGATIVE (GND)
+12V AUX POWER
24HR N/C ZONE INPUT
ALARM
ZONE (COM)
ZONE
5 MIN
JP5: MEMORY RESET
MOMENTARILY SHORT
TO RESET LINE FAULT
MEMORY
5
T
HOUSE
PHONES
8 WIRE FULL
MODULAR CABLE
(MALE TO MALE)
FIGURE 2: USING WIRES IN PHONE CORD J1 FOR POWER AND RELAY
JUMPERS JP2 AND JP4 MUST BE SET AS SHOWN FOR THIS CONFIGURATION
JUMPER JP2: POWER HOOKUP
NO
JUMPER JP4: RELAY HOOKUP
A B C
SET JUMPERS ON "A & C" TO
CONNECT RELAY NC & COM
USING WIRES 2 & 7 ON J1
(CLOSED CIRCUIT ONLY)
RELAY OPENS ON FAULT
JUMPER JP3: INPUT VOLTAGE
SET TO "YES" TO
HOOKUP POWER USING
WIRES 3 & 6 ON J1
YES
24V 12V
THE ELK-980 CAN BE
POWERED FROM A 12V OR
24VDC POWER SUPPLY
AB C
JP4
JP1
5 MIN
30 SEC
JP2
24V 12V
JP3
YES
NO
SECURITY/PHONE
EQUIPMENT
RING
TELCO
WIRE WIRE
NO. COLOR
4 RED
TIP
5 GREEN
R1
1 SLATE
T1
8 BROWN
24HR N/C ZONE INPUT
ALARM
ZONE (COM)
ZONE
NEGATIVE (GND)
AUX
POWER +12V AUX POWER
7 BLUE
8 PIN
JACK
OUT
J1
8 PIN
JACK
IN
J2
JP5
D7
RESET
STATUS
JUMPER JP1: DELAY AFTER FAULT
NEG POS N/O COM N/C
POWER ALARM RELAY
ELK-980
Telephone Line
Fault Module
SETS TIME DELAY BEFORE RELAY
OPENS AFTER LINE FAULT
30 SEC
THESE TERMINALS ARE NOT
USED IN THIS CONFIGURATION
RJ31X JACK
(ELK-950 Recommended)
R1
1
2
3
8
7
8 WIRE QTR.
JP5: MEMORY RESET
8 WIRE FULL
T1
MODULAR CABLE MOMENTARILY SHORT
MODULAR CABLE
(MALE TO SPADE) TO RESET LINE FAULT
(MALE TO MALE)
REQUIRED
MEMORY
6
J1
6 YELLOW
R
4
J2
2 ORANGE
3 BLACK
5 MIN
INCOMING
TELCO
LINE
5
T
HOUSE
PHONES