* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Energy Plus Heater
Power engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Thermal runaway wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electrical substation wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Rectiverter wikipedia , lookup
Earthing system wikipedia , lookup
Mains electricity wikipedia , lookup
Energy Plus Heater Owner’s Guide %HQH¿WV<RX&DQ'HSHQG2Q Information is also available on our website: http://www.cadetheat.com/products/wall-heaters/energy-plus • 6HQVLEOHDQGHQHUJ\HI¿FLHQWXVHXSWROHVV energy (QHUJ\3OXV0RGHOV • %ULQJV\RXRQO\WKHKHDW\RXQHHGZKHQ\RXQHHGLW and adjusts automatically to save you money /LQH 9ROWDJH 0RGHO :DWWV $PSV 120 (37 1000 8.3 • <RXGH¿QH\RXUFRPIRUW²PDLQWDLQV\RXUURRPWHPperature within one degree Energy Plus Model With Built-In Controller :DOO7KHUPRVWDW1RW5HTXLUHG • Our most thoughtful design features: Large digital display shows your room temperature and heating mode Before pushing RESET button see Owner’s Guide for display fault 3108579 codes and other conforms troubleshooting to UL STD information. 2021 072xxx Disconnect power at circuit breaker before servicing. Do not operate without grill. ,PSURYHDLUFLUFXODWLRQDGGFRPIRUWLQRIIVHDVRQ with three fan speeds WARNING! TO AVOID ELECTRICAL SHOCK Night/Away option for extra savings Model: Volts: Watts: cadetheat.com Vancouver, WA Mfg Date: (DV\LQWXLWLYHRQHWRXFKFRQWUROV Rating Label NO F • ,QVWDOOVLQHDV\VWHSV NO HEAT Controller with Digital Display and Push Buttons • Common sense components designed with you in mind: Peace of mind safety with automatic high temperature shutoff Side Grill Front Wall Can Side No sharp edges Corrosion resistant Our sturdiest element provides comfortable warmth for years of reliable use 12” 30.5cm + • Your Energy Plus heater has been thoroughly tested and is guaranteed with a \HDUH[WHQGHGZDUUDQW\ 10” 25.4cm 111/8” 28.3cm NO F NO HEAT 3¼” 8.3cm SLEEP 5 /8” 1.6cm 1¼” 3.2cm FAN ONLY HEAT 9” 22.9cm Wall Can Bottom 7 7/8” 20.0cm 3” 7.6cm 4” 10.2cm COM-PAK 1¾” 4.5cm Conforms to UL Std. DQG&HUWL¿HGWR CAN/CSA Std. C22.2 No. 46 1¼” 3.2cm PATENT PENDING TOOLS REQUIRED: • Phillips Screwdriver • Straight Screwdriver • Wire Strippers • Utility Knife • (4) 1½" Wood Screws • (2) Insulated Wire Connectors • (1) Strain Relief Connector SAVE THESE INSTRUCTIONS cadetheat.com Tel: 855.CADETUS PO Box 1675 Vancouver, WA 98668-1675 Page 1 IMPORTANT INSTRUCTIONS :$51,1* :KHQXVLQJHOHFWULFDODSSOLDQFHVEDVLFSUHFDXWLRQVVKRXOGDOZD\VEHIROORZHGWRUHGXFHWKHULVNRI¿UH HOHFWULFVKRFNDQGLQMXU\WRSHUVRQVLQFOXGLQJWKHIROORZLQJ 1. Read all instructions before installing or using :$51,1* this heater. Risk of Electrical Shock. Do not insert or allow foreign objects to enter any ventilation or exhaust 2. :$51,1* opening as this may cause an electric shock or Risk of Fire. This heater is hot when in use. &DXWLRQ²+LJK 7HPSHUDWXUH 5LVN RI )LUH .HHS ¿UHRUGDPDJHWKHKHDWHU HOHFWULFDO FRUGV GUDSHU\ IXUQLVKLQJV DQG RWKHU :$51,1* FRPEXVWLEOHVDWOHDVWIHHWPIURPWKHIURQW 5LVN RI )LUH 7R SUHYHQW D SRVVLEOH ¿UH GR QRW RIWKHKHDWHUDQGLQFKHVFPDERYHDQG block air intakes or exhaust in any manner. on both sides. :$51,1* :$51,1* Fire or explosion may occur. A heater has hot and %XUQ+D]DUG7RDYRLGEXUQVGRQRWOHWEDUHVNLQ arcing or sparking parts inside. Do not use it in touch hot surfaces. Extreme caution is necessary DUHDVZKHUHJDVROLQHSDLQWRUÀDPPDEOHYDSRUV when any heater is used by or near children or or liquids are used or stored. invalids and whenever the heater is left operating 8VH WKLV KHDWHU RQO\ DV GHVFULEHG LQ WKLV and unattended. manual. Any other use not recommended by the 4. :$51,1* PDQXIDFWXUHUPD\FDXVH¿UHHOHFWULFDOVKRFNRU Risk of Electrical Shock. Do not operate any injury to persons. heater after it malfunctions. Disconnect power 11. The heater must be properly installed before at service panel and have heater inspected by a it is used. TXDOL¿HGHOHFWULFLDQEHIRUHUHXVLQJ 12. :$51,1* :$51,1* Risk of Electrical Shock and Fire. Do not operate Do not use outdoors. without grill. 7RGLVFRQQHFWKHDWHUWXUQFRQWUROVWRRIIDQG 6DYHWKHVHLQVWUXFWLRQV turn off power to heater circuit at main disconnect panel. Wiring Diagram 1 2 3 4 1 2 3 4 RED WHITE BLACK HEATING ELEMENT BLACK MANUAL RESET HIGH TEMPERATURE LIMIT VOLTAGE KEY MOTOR THERMOSTAT CONTROL THERMISTOR RED WHITE WHITE YELLOW BLACK YELLOW BROWN MODE SWITCH L1 L2 or N ORANGE SAVE THESE INSTRUCTIONS cadetheat.com Page 2 Tel: 855.CADETUS PO Box 1675 Vancouver, WA 98668-1675 %HIRUH\RXEHJLQ\RXVKRXOGNQRZ DERXWWKH&DGHW(QHUJ\3OXVKHDWHU 7KH&DGHW(QHUJ\3OXV+HDWHUSURYLGHVZDUPWKDQGFRPIRUWWRDURRPE\XVLQJDQHI¿FLHQW YDULDEOHVSHHGIDQWRFLUFXODWHWKHZDUPDLUDQGDQLQWHOOLJHQWWKHUPRVWDWWRGHOLYHUSUHFLVH temperature control. The Cadet Energy Plus heater is designed to save energy and run at a low speed and heat output once the desired room temperature is reached. This is normal operation for maintaining and regulating desired room temperature. This low speed fan movement also provides better DLUPL[LQJZLWKLQWKHURRPDQGIHZHURQRIIF\FOHV + NO F NO HEAT A 6DIHW\LV&DGHW¶V¿UVWSULRULW\$OOKHDWHUVIHDWXUHDKLJKWHPSHUDWXUHOLPLWVZLWFKWKDWVKXWVWKH heater off when excessive operating temperatures are detected. SLEEP FAN ONLY HEAT )RUHIIHFWLYHDQGVDIHRSHUDWLRQDQGWRSURORQJWKHOLIHRIWKHKHDWHUUHDGDOOLQVWUXFWLRQVDQG VDIHW\LQIRUPDWLRQDQGIROORZWKHPDLQWHQDQFHLQVWUXFWLRQVLQWKLV2ZQHU¶V*XLGH VRPHJHQHUDOWLSV NO SLEEP NO HEAT A + F FAN ONLY HEAT 7KHKHDWHUKDVDFRROGRZQIHDWXUHWKDWZLOOUXQWKHIDQIRUXSWRPLQXWHVDIWHUVZLWFKLQJWR FAN ONLY mode or if set point is reached and mild outdoor temperatures create low demand. 7KLVLVQRUPDO7KHDLUEHLQJGLVFKDUJHGPD\IHHOFRROEXWLVDFWXDOO\URRPWHPSHUDWXUHUHVLGXal heat moving into the room. %HFDXVHWKHGLJLWDOWKHUPRVWDWLVEXLOWLQWKH(QHUJ\3OXVKHDWHULWLVYHU\LPSRUWDQWWRFRQGXFWSURSHUPDLQWHQDQFH6HH3DJHRIWKHKHDWHUWRPDLQWDLQSHDNSHUIRUPDQFHDQGVDIHW\ 7KH&DGHW(QHUJ\3OXVKHDWHU¶VXQLTXHYDULDEOHVSHHGEORZHUZLOODXWRDGMXVWEDVHGRQWKH URRPUHTXLUHPHQWVDQGKHDWRXWSXW,WZLOOTXLHWO\GHOLYHUKHDWDWDORZVSHHGIRURSWLPXPSHUformance and energy savings once desired temperature setpoint is reached. VRPHLQVWDOODWLRQIDFWV )RUQHZLQVWDOODWLRQ\RXVKRXOGEHSUHSDUHGWRUXQZLUHRUHOHFWULFDOFRQGXLWWR\RXUGHVLUHG location for your heater. $TXDOL¿HGRUGHGLFDWHGFLUFXLWIURPWKHPDLQGLVFRQQHFWSDQHOLVUHTXLUHG $QLQZDOOHOHFWULFIDQKHDWHULVDSHUPDQHQWVDIHKDUGZLUHGVROXWLRQWKDWUHTXLUHVDFXWRXW LQ\RXUZDOOWRUHFHVVWKHKHDWHUXQOHVVD&DGHWVXUIDFHPRXQWDGDSWHULVXVHG • The Cadet Energy Plus heater must only be installed vertically in a wall. 7KHKHDWHUPXVWQRWEHLQVWDOOHGLQWKHÀRRURUFHLOLQJHYHQLI\RXDUHUHSODFLQJDQH[LVWLQJ heater that was installed in either of these locations. • Installation on an inside wall is recommended. )RUEHWWHUFRPIRUWGRQRWLQVWDOOZKHUHDLULVOLNHO\WRFRQWLQXRXVO\EORZGLUHFWO\RQWR\RXRU another person. 7KHUHFRPPHQGHGKHLJKWIURPWKHÀRRULVLQFKHVFPIRUHDV\DFFHVVWRWKHGLJLWDO WKHUPRVWDW,WZLOOIXQFWLRQSURSHUO\LQORZHUSRVLWLRQVEXWPXVWQRWEHORZHUWKDQòLQFKHV FPDERYHWKHÀRRU + • The Cadet Energy Plus heater must only be installed with a Com-Pak style wall can model CC. %HVXUHWKDW\RXUZDOOFDQLVPRXQWHGÀXVKZLWKWKHRXWVLGHRIWKHVKHHWURFN NO F NO HEAT A SLEEP FAN ONLY HEAT WKDWDZDOOWKHUPRVWDWLVQRWUHTXLUHG A wall thermostat may not be used to control this heater. The Energy Plus heater is equipped with a unique built-in thermostat that both regulates the heater output and provides precise WHPSHUDWXUHFRQWURO,IUHSODFLQJDKHDWHUFRQWUROOHGE\DQH[LVWLQJZDOOWKHUPRVWDWUHPRYHZDOO thermostat from the heater circuit and cover hole with a faceplate. Black wires To breaker To heater All ground wires Remove thermostat 725(029($1(;,67,1*:$//7+(50267$7)520+($7(5&,5&8,7 1. Make sure power is off at the main disconnect panel. 2. Remove wall thermostat mounting screws. 3XOOWKHWKHUPRVWDWDZD\IURPWKHZDOODQGFRXQWWKHZLUHV $,I\RXFRXQWEODFNVXSSO\ZLUHVDQGZKLWHVXSSO\ZLUHVLQWKHER[GLVFRQQHFW thermostat and connect the 2 black wires together with one wire connector (not included). Connect the 2 white wires together with another wire connector (not included). Connect all ground wires together. Junction %,I\RXKDYHEODFNVXSSO\ZLUHDQGZKLWHVXSSO\ZLUHGLVFRQQHFWWKHUPRVWDWDQG box cover connect the black and white wires together with a wire connector (not included). Connect (not included) all ground wires together. &,I\RXKDYHPRUHWKDQEODFNRUZKLWHZLUHVSOHDVHFRQVXOWDTXDOL¿HGHOHFWULFLDQ ,I\RXKDYHDPHWDOMXQFWLRQER[LWPXVWEHJURXQGHGXVHDJURXQGLQJVFUHZRUFOLS 6. Install a blank faceplate (not included) over the exposed junction box. White wires 3DJH INSTALLATION INSTRUCTIONS 1. :$51,1* Verify that the electrical supply wires are the same voltage as the heater. ,IUHSODFLQJDQH[LVWLQJKHDWHUFKHFNWKHODEHO of the old heater. $OO HOHFWULFDO ZRUN DQG PDWHULDOV PXVW FRPSO\ ZLWKWKH1DWLRQDO(OHFWULF&RGH1(&WKH2FFXSDWLRQDO 6DIHW\ DQG +HDOWK$FW 26+$ DQG DOO state and local codes. 4. If you need to install a new circuit or need addiWLRQDOZLULQJLQIRUPDWLRQFRQVXOWDTXDOL¿HGHOHFtrician. 8VHFRSSHUFRQGXFWRUVRQO\ 6. :$51,1* Risk of Electrical Shock. DO NOT install the heater directly above bathtub or sink. DO NOT install in shower stall area. Manufacturer recommends a minimum 2 foot (61 cm) clearance. +HDWHUPXVWEHLQVWDOOHGLQDZDOOFDQ Model EP Wall Can CC __________________________ :$51,1* 5LVNRI)LUH'2127LQVWDOOWKHKHDWHULQDÀRRU LQ WKH FHLOLQJ EHORZ D WRZHO EDU EHKLQG D GRRU or anywhere the air discharge may be blocked in any manner. :$51,1* Fire or Explosion May Occur. A heater has hot and arcing or sparking parts inside. Do not use it LQDUHDVZKHUHJDVROLQHSDLQWRUÀDPPDEOHYDpors or liquids are used or stored. :$51,1* Risk of Electrical Shock. Connect grounding lead to grounding screw provided. Keep all foreign objects out of heater. 11.:$51,1* Risk of Fire. This heater is hot when in use. &DXWLRQ²+LJK 7HPSHUDWXUH 5LVN RI )LUH .HHS HOHFWULFDO FRUGV GUDSHU\ IXUQLVKLQJV DQG RWKHU FRPEXVWLEOHVDWOHDVWIHHWPIURPWKHIURQW RIWKHKHDWHUDQGLQFKHVFPDERYHDQG on both sides. 3DUW2QH __________________________ PLACEMENT: Install vertically. Heater is not approved for horizontal or ceiling mount applications. CONTROLS: A built-in digital thermostat is included. May not be used with a wall thermostat. How do I install for new construction? STEP 1 0RXQW7KH:DOO&DQ 5(48,5('0,1,080GLVWDQFHRIôLQFKHVFPIURP DGMDFHQWVXUIDFHVVXFKDVZDOOVDQGòLQFKHVFPIURP WKHÀRRU6HH)LJXUH+RZHYHU&DGHWUHFRPPHQGVLQFKHV FPIURPDGMDFHQWVXUIDFHVDQGÀRRUIRUORQJHUDQGFOHDQHU SHUIRUPDQFH+HDWHUVPXVWEHVSDFHGDWOHDVWIHHWP apart. Secure the wall can to the stud with 2 screws (not included). (See )LJXUHV$VDQRSWLRQWKHUXEEHUVKLPSURYLGHGPD\EH attached to side of wall can to square the wall can to the stud. )LJXUH Face of wall can must extend òLQFKFP RUǫLQFK cm) from face of stud to allow for thickness of sheetrock. How do I install in an existing wall? STEP 1 &XW$+ROH,Q7KH:DOO 5(48,5('0,1,080GLVWDQFHRIôLQFKHVFPIURP DGMDFHQWVXUIDFHVVXFKDVZDOOVDQGòLQFKHVFPIURP WKHÀRRU6HH)LJXUH+RZHYHU&DGHWUHFRPPHQGVLQFKHV FPIURPDGMDFHQWVXUIDFHVDQGÀRRUIRUORQJHUDQGFOHDQHU SHUIRUPDQFH+HDWHUVPXVWEHVSDFHGDWOHDVWIHHWP apart. &XWDKROHLQFKHVFPZLGHE\óLQFKHVFP high next to a wall stud. STEP 2 5RXWH6XSSO\:LUHV Route supply wire from the circuit breaker to the heater. Remove a knockout from the wall can and attach the supply wire with a strain relief connector (not included) leaving a minimum of 6 inchHVFPZLUHOHDG&RQQHFWVXSSO\JURXQGZLUHWRJURXQGLQJ VFUHZLQZDOOFDQ6HH)LJXUH SUPPLY WIRE )LJXUH Attach wall can to stud with screws (not included) through holes provided in wall can. IMPORTANT: wall FDQVKRXOGEHPRXQWHGÀXVKZLWK outside of sheetrock. KNOCK-OUT (TWIST TO REMOVE) ¾" (1.9cm) Min. STRAIN RELIEF CONNECTOR GROUNDING SCREW )LJXUH STEP 2 5RXWH6XSSO\:LUHV Route supply wire from the circuit breaker to the heater. Remove a knockout from the wall can and attach the supply wire with a strain relief connector (not included) leaving a minimum of 6 inchHVFPZLUHOHDG&RQQHFWVXSSO\JURXQGZLUHWRJURXQGLQJ VFUHZLQZDOOFDQ6HH)LJXUH Proceed to Part Two. Page 4 )LJXUH 67(3 0RXQW7KH:DOO&DQ ,QVHUWZDOOFDQLQWRRSHQLQJNHHSLQJZDOOFDQÀXVKZLWKZDOOVXUface. Secure can to wall stud with 2 screws (not included) through holes provided in can. IMPORTANT: wall can should be mounted ÀXVKZLWKRXVLGHRIVKHHWURFN Proceed to Part Two. INSTALLATION INSTRUCTIONS (continued) __________________________ __________________________ 3DUW7ZR STEP 1 9HULI\6XSSO\9ROWDJH $TXDOL¿HGRUGHGLFDWHGFLUFXLWIURPPDLQGLVFRQQHFWSDQHOLVUHTXLUHG %HIRUHLQVWDOOLQJYHULI\SRZHUVXSSO\LVYROWV How do I insert the heater assembly into the wall can? STEP 2 ,QVWDOO+HDWHU$VVHPEO\ 7XUQKHDWHUDVVHPEO\VRWKDWWKHIURQWLVIDFLQJWKHÀRRUHOHPHQWGRZQZLWKPRWRUIDFLQJXS<RXFDQWKHQUHVWERWWRPHGJHRIWKH KHDWHUDVVHPEO\RQWKHERWWRPRIWKHZDOOFDQZKLOHVXSSRUWLQJWKHHGJHFORVHVWWR\RX6HH)LJXUH Connect the supply wires to the heater wires with wire connectors (not included). (See Figure 6). Now rotate heater assembly into wall FDQVRWKDWWKHERWWRPHGJHGURSVLQWRWKHKDOIURXQGVORWVLQERWWRPOLSRIZDOOFDQ6HH)LJXUH ,03257$17 Push wires into bottom and left side of wall can during insertion. Be sure supply wires are not caught between motor and wall can. $IWHUFRQ¿UPLQJWKDWWKHERWWRPHGJHRIKHDWHULVSRVLWLRQHGLQWKHVORWVLQERWWRPOLSRIZDOOFDQDWWDFKDVVHPEO\DWWRSZLWKVFUHZ provided. 67(3 ,QVWDOO*ULOO $OLJQSXVKEXWWRQVDQGGLJLWDOGLVSOD\ZLWKJULOOFXWRXWVEHIRUHWLJKWHQLQJZLWKJULOOVFUHZVSURYLGHG'RQRWRYHUWLJKWHQ6HH)LJXUH STEP 4 &RQ¿UP3URSHU,QVWDOODWLRQ 7XUQHOHFWULFDOSRZHUEDFNRQDWWKHPDLQGLVFRQQHFWSDQHO:$,7VHFRQGVIRUKHDWHUWRSRZHUXSEHIRUHSXVKLQJDQ\EXWWRQV 7KH(QHUJ\3OXVKHDWHULVHTXLSSHGZLWKDVPDUWVHQVRUWKDWZLOOLQGLFDWHLIWKHYROWDJHGRHVQRWPDWFKWKHUHTXLUHGYROWVXSSO\ If the heater has been properly installed: 'LVSOD\EDFNOLJKWZLOOFRPHRQDQGUHDG³´IRUDPRPHQWWKHQÀDVKWKHWHPSHUDWXUHVHWSRLQWLILQ+($7PRGHRURULILQ FAN ONLY mode. $IWHUVHFRQGVURRPWHPSHUDWXUHZLOOEHGLVSOD\HG Proceed to OPERATING INSTRUCTIONS. ,IWKHKHDWHUKDVEHHQLPSURSHUO\LQVWDOOHGD)DXOW&RGHZLOOGLVSOD\6HH)DXOW&RGHVSDJH )LJXUH )LJXUH )LJXUH )LJXUH 3DJH OPERATING INSTRUCTIONS :$51,1*Risk of Electrical Shock and Fire. The heater must be properly installed before it is used. 1. Do not operate without grill. .HHSHOHFWULFDOFRUGVGUDSHU\IXUQLVKLQJVDQG RWKHUFRPEXVWLEOHVDWOHDVWIHHWPDZD\ IURP WKH IURQW RI WKH KHDWHU DQG LQFKHV cm) away from the sides. 'RQRWWDPSHUZLWKWKHRYHUWHPSHUDWXUHOLPLW control. 4. If the heater over temperature limits trip more WKDQRQFHSHUGD\WKHKHDWHUPXVWEHUHSODFHG &OHDQKHDWHUDWOHDVWHYHU\VL[PRQWKV $IWHUDOORZLQJWKHKHDWHUWRFRROWXUQSRZHURII at circuit breaker panel before removing grill. 8VH D KDLU GU\HU RU YDFXXP RQ EORZ F\FOH to blow debris through the top element (do not touch element). ,QVWDOOWKHJULOOEHIRUHWXUQLQJRQSRZHU :$51,1* Any other service not detailed in this Owner’s Guide should be performed by an authorized service representative. &RQWURO%XWWRQV 'LJLWDO'LVSOD\ )DQ0RGH ,QGLFDWRU )DQ2SHUDWLRQ )DKUHQKHLW6HWWLQJ 7HPSHUDWXUH 1LJKW$ZD\0RGH ,FRQ 3URSRUWLRQDO+HDW &RQWURO,QGLFDWRU +HDWLQJ 0RGH ,QGLFDWRU +HDWHU0RGHV 8VLQJWKHURFNHUVZLWFK\RXFDQPRYHWKHVZLWFKWRWZRPRGHV HEAT FAN ONLY 8S%XWWRQ + NO 'LJLWDO'LVSOD\ F NO HEAT A 'RZQ%XWWRQ 1LJKW%XWWRQ 5RFNHU6ZLWFK NIGHT / SLEEP AWAY NO FAN NO HEAT HEAT FAN ONLY 6HWWLQJ'HVLUHG+HDWLQJ7HPSHUDWXUH • Push rocker switch to HEAT mode. • Touch the up button or the down button to set your desired temperature. 7HPSHUDWXUH6HWSRLQW5DQJHÛ)Û) Û&Û& FAN ONLY HEAT 8S 'RZQ 5RFNHU6ZLWFK /()7326,7,21+($702'( Your Com-Pak Energy Plus heater has a unique variable speed blower that auto adjusts the heat output based on the room’s requirements. Once you set the thermostat to your desired temSHUDWXUHWKHKHDWHUZLOOYDU\WKHZDWWDJHRXWSXWIRUPD[LPXP HI¿FLHQF\ The digital display will show the level of heat being output to maintain the room’s temperature. +HDWLQJ)XOO3RZHU +HDWLQJ0LG3RZHU 5,*+7326,7,21)$121/<02'( +HDWLQJ/RZ3RZHU The FAN ONLY mode can circulate air but will not supply heat. Three fan speeds are available. To adjust the fan speed: With URFNHUVZLWFKLQWKH5,*+7SRVLWLRQSXVK8SRU'RZQGLJLWDOEXWWRQV'LVSOD\ZLOOUHDG³´IRUORZVSHHG³´IRUPHGLXP VSHHGRU³´IRUKLJKVSHHGGXULQJWKHVHWXSSURFHVVWKHQ resume to temperature display. )DQ2QO\1R+HDW Page 6 3URJUDPPLQJ<RXU1LJKW$ZD\%XWWRQ You can preset a night or away temperature VHWSRLQWIRUTXLFNDQGHDV\³RQHWRXFK´ NIGHT / energy savings. AWAY • Push rocker switch to HEAT mode. • Push Night button to activate. The moon 1LJKW$ZD\ icon will show in display screen. The “night/ %XWWRQ DZD\´VHWSRLQWWHPSHUDWXUHZLOOÀDVKIRU seconds. • Push the Up or Down button to change your desired night/away set point. • To return to your previous HEAT set point ZKHQ\RXDZDNHRUUHWXUQSXVKWKH1LJKW DJDLQ7KHVHWSRLQWWHPSHUDWXUHZLOOÀDVK IRUVHFRQGV7KHPRRQLFRQZLOOQRORQJHU be in display screen. • To return to your previous night/away set1LJKW$ZD\0RGH SRLQWVLPSO\SXVKWKH1LJKWEXWWRQ (QHUJ\6DYLQJ7LSV • Set your Night/Away set point to as low as you are comIRUWDEOHIRUDFRROHUQLJKWWLPHWHPSHUDWXUH • :KHQ\RXH[LWWKHURRPRUOHDYH\RXUKRPHSXVKWKH1LJKW button to drop the temperature set point. • If your heater is positioned in a drafty area or exposed to GLUHFWVXQOLJKWWHPSHUDWXUHUHDGLQJZLOOEHDIIHFWHG6HWWHPSHUDWXUHWRGHVLUHGFRPIRUWOHYHOQRWD³QXPEHU´RQWKHGLJLWDO display. OPERATING INSTRUCTIONS (continued) Fault Codes Digital Display Reads No Display Problem Solution &KHFNWKDWSRZHULVEHLQJVXSSOLHGWRKHDWHULIRSHUDWLQJRQJHQHUDWRUSRZHU 1RSRZHULQWHUQDOIXVH FRQ¿UPJHQHUDWRUVHWWLQJLIGLVSOD\VWLOOGRHVQ¶WWXUQRQFRQWUROLVIDXOW\5HSODFH EORZQLQWHUQDOFRQWUROIDXOW\ heater assembly. F1 Grill is interfering with buttons 7XUQSRZHURIIDWPDLQGLVFRQQHFWSDQHOUHDOLJQJULOOVREXWWRQVFDQSXVKIUHHO\ Turn power back on at main disconnect panel. F3 Wrong supply voltage (QVXUHVXSSO\YROWDJHLVYROWV F4 1. Line voltage is too low /RRVHZLUHFRQQHFWLRQV or voltage key is not fully engaged 1. Clears automatically when line voltage returns to normal. 2. Check wire connections and that voltage key is securely in place. F6 Line voltage is too high Clears automatically when line voltage returns to normal. F7 Thermal limit (temperature limiting control) tripped ,QVSHFWKHDWHUIRUEORFNDJHREVWUXFWLRQDQGRUSURSHUFOHDUDQFH0RYHURFNHU switch to (FAN ONLY) position and wait for heater to cool. Push manual reset limit EXWWRQSHUWKH0$,17$,1,1*<285+($7(5LQVWUXFWLRQV3DJH F8 Internal control fault 'LVFRQQHFWSRZHUUHFRQQHFWSRZHU,I)FRGHUHWXUQVFRQWUROLVIDXOW\5HSODFH heater assembly. Loose voltage key 7XUQSRZHURIIDWWKHPDLQGLVFRQQHFWSDQHOFKHFNYROWDJHNH\WXUQSRZHUEDFN on at main disconnect panel. 12 or 24 $ERXWWKH0DQXDO5HVHW7HPSHUDWXUH/LPLW&RQWURO The heater is protected by a temperature-limiting control. The manual reset temperature limit control is designed to open the heater cirFXLWDQGVWRSWKHHOHFWULFDOFXUUHQWÀRZ when excessive operating temperatures are detected. The problem must be assessed (typically the heater is blocked or needs cleaning) and the limit must be reset to resume operation. Resetting the Manual Reset Limit Control Before pushing RESET button see Owner’s Guide for display fault 3108579 codes and other conforms troubleshooting to UL STD information. 2021 Manual Reset Limit Button Disconnect power at circuit breaker before servicing. Do not operate without grill. 072xxx WARNING! TO AVOID ELECTRICAL SHOCK Model: Volts: Watts: If the manual reset limit control has opened the heater circuit due to excessive operating temperaWXUHVWKHKHDWHUZLOOQRWZRUNXQWLOWKHPDQXDOUHVHWOLPLWEXWWRQLVSUHVVHG 7KH³PDQXDOUHVHWOLPLWEXWWRQ´LVWKHUHGEXWWRQORFDWHGRQWKHXSSHUOHIWVLGHRI\RXUKHDWHUEHKLQG the grill louvers just above the digital temperature display. $IWHUDOORZLQJWKHXQLWWRFRROIRUDWOHDVWPLQXWHVDQGUHVROYLQJWKHSUREOHPFDXVLQJWKHOLPLWWR trip (typically the heater is blocked or needs cleaning); use a narrow object such as a ball-point pen to access the manual reset button through the upper-left center section of the heater grill. Press ),50/<DQGEHVXUHWROLVWHQDQGIHHOIRUDFOLFNLQGLFDWLQJLWKDVEHHQUHVHW cadetheat.com Vancouver, WA Mfg Date: 5HVHWWLQJWKH0DQXDO5HVHW7HPSHUDWXUH/LPLW&RQWURO NO F NO HEAT Warranty For more effective and safer operation and to prolong the life of WKHKHDWHUUHDGWKH2ZQHU¶V*XLGHDQGIROORZWKHPDLQWHQDQFH instructions. Failure to properly maintain the heater will void any warranty and may cause the heater to function improperly. Warranties are non transferable and apply to original consumer only. Warranty terms are set out below. /,0,7('),9(<($5:$55$17<Cadet will repair or replace DQ\(QHUJ\3OXV(3KHDWHUIRXQGWREHGHIHFWLYHZLWKLQ¿YH years after the date of purchase. 7KHVHZDUUDQWLHVGRQRWDSSO\ 1. Damage occurs to the product through improper installation or incorrect supply voltage; 'DPDJHRFFXUVWRWKHSURGXFWWKURXJKLPSURSHUPDLQWHQDQFHPLVXVH DEXVHDFFLGHQWRUDOWHUDWLRQ 7KHSURGXFWLVVHUYLFHGE\DQ\RQHRWKHUWKDQ&DGHW 4. If the date of manufacture of the product cannot be determined; ,IWKHSURGXFWLVGDPDJHGGXULQJVKLSSLQJWKURXJKQRIDXOWRI&DGHW 6. The use of unauthorized accessories or unauthorized components constitutes an alteration and voids all warranties. Refer to Cadet website RUFDOOFXVWRPHUVHUYLFHDW&$'(786IRUOLVWRIDXWKRUL]HGDFFHVVRries and components. &$'(7¶6:$55$17<,6/,0,7('725(3$,5255(3/$&(0(17 AS SET OUT HEREIN. CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EXPENSES RESULTING FROM BREACH OF THESE WRITTEN WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY. ,17+((9(17&$'(7(/(&76725(3/$&($1<3$572)<285 &$'(7352'8&77+(5(3/$&(0(173$576$5(68%-(&772 THE SAME WARRANTIES AS THE PRODUCT. THE INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES. REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES. 7KHVHZDUUDQWLHVJLYH\RXVSHFL¿FOHJDOULJKWVDQG\RXPD\DOVR KDYHRWKHUULJKWVZKLFKYDU\IURPVWDWHWRVWDWH&DGHWQHLWKHUDVVXPHV QRUDXWKRUL]HVDQ\RQHWRDVVXPHIRULWDQ\RWKHUREOLJDWLRQRUOLDELOLW\LQ connection with its products other than as set out herein. ,I\RXEHOLHYH\RXU&DGHWSURGXFWLVGHIHFWLYHSOHDVHFRQWDFW&DGHW 0DQXIDFWXULQJ&RDW&$'(786GXULQJWKHZDUUDQW\SHULRGIRU instructions on how to have the repair or replacement processed. Warranty claims made after the warranty period has expired will be denied. Products returned without authorization will be refused. 3DUWVDQG6HUYLFH Visit cadetheat.com/parts-service for information on where to obtain parts and service. 5HGXFH5HXVH5HF\FOH This product is made primarily of recyclable materials. You can reduce your carbon footprint by recycling this product at the end of its useful life. Contact your local recycling support center for further recycling instructions. 3DJH MAINTAINING YOUR HEATER Maintenance As Needed, or every six months minimum. :$51,1*%HIRUHUHPRYLQJJULOOWXUQWKHHOHFWULFDOSRZHURIIDWWKHPDLQGLVFRQQHFWSDQHO (circuit breaker or fuse box). Lock or tag the main disconnect panel door to prevent someone from accidentally turning the power on while you are working on the heater. Failure to do so FRXOGUHVXOWLQVHULRXVHOHFWULFDOVKRFNEXUQVRUSRVVLEOHGHDWK :$51,1*Any other service not detailed in this Owner’s Guide should be performed by an authorized service representative. 1. It is important that you verify power has been turned off and no power is going to the heater before proceeding. Circuit breakers are often not marked correctly and turning the wrong breaker off FRXOGPHDQHOHFWULFLW\LVÀRZLQJWRWKHKHDWHUHYHQLIWKHKHDWHU does not appear to be working. If you are uncomfortable working ZLWKHOHFWULFDODSSOLDQFHVXQDEOHWRIROORZWKHVHJXLGHOLQHVRUGR QRWKDYHWKHQHFHVVDU\HTXLSPHQWFRQVXOWDTXDOL¿HGHOHFWULFLDQ 2QFH\RXYHULI\WKHSRZHUKDVEHHQWXUQHGRIIFRUUHFWO\SURceed to the next step. 5HPRYHVFUHZVDQGWDNHRIIJULOO 4. Wash grill with hot soapy water and dry. :KLOHKROGLQJIDQWRDYRLGGDPDJHRUEHQGLQJXVHDKDLUGU\HU or vacuum on blow cycle to blow debris through the top element (do not touch element). 6. Vacuum fan area without touching the elements. 'RQRWOXEULFDWHPRWRU 5HSODFHJULOODQGVHFXUHZLWKVFUHZV 7XUQWKHUPRVWDWWRGHVLUHGVHWWLQJ 7XUQSRZHUEDFNRQDWWKHPDLQGLVFRQQHFWSDQHO Troubleshooting Chart &2168/7/2&$/(/(&75,&$/&2'(672'(7(50,1(:+$7:25.0867%(3(5)250('%<48$/,),(' (/(&75,&$/6(59,&(3(56211(/ Symptom Problem +HDWHULVZRUNLQJ but room does not reach desired temperature. 1. Heat loss from room is greater than heater capacity.* Breaker trips immediately upon energizing heater. 1. Overloaded circuit.* 2. Furniture or other surfaces may be too close to the heater. Solution &ORVHGRRUVDQGZLQGRZV3URYLGHDGGLWLRQDOLQVXODWLRQRULQVWDOODKLJKHU wattage heater or multiple heaters if necessary. (If your circuit is rated for more capacity.) 5HPRYHIXUQLWXUHRURWKHUVXUIDFHVWRDSSURSULDWHFOHDUDQFHVVRDLUFDQÀRZ IUHHO\WKURXJKRXWURRP0DLQWDLQDPLQLPXPGLVWDQFHRIôLQFKHVFPIURP DGMDFHQWVXUIDFHVòLQFKHVFPIURPWKHÀRRUDQGIHHWPIURP furniture or other objects placed directly in front of the heater. 'HIHFWLYHFLUFXLWEUHDNHU 4. Thermostat malfunction. 1. The total amperage of all heaters on a branch circuit must not be more than RIWKHDPSHUDJHUDWLQJRIWKHFLUFXLWEUHDNHUDQGVXSSO\ZLUHUDWLQJV8VHD ORZHUZDWWDJHKHDWHURUUHGXFHWKHQXPEHURIKHDWHUVRQWKHFLUFXLW 2. Shorted supply or heater wires may be accompanied by severe sparking. Inspect all supply and heater wiring insulation for damage. Do not reset the circuit breaker until all electrical shorts have been repaired. 5HSODFHWKHFLUFXLWEUHDNHU 4. Replace heater assembly. Heater fan operDWHVEXWGRHVQRW discharge warm air. 1. Rocker switch is not set to HEAT mode. 2. Element has failed.* 1. Push rocker switch to HEAT mode. 2. Replace element. Heater will not shut off. 1. Heater continues to run at low speed. ,IURRPWHPSHUDWXUHLVEHLQJUHJXODWHGDQGPDLQWDLQHGDORZIDQVSHHGDQGORZ heat output is normal for this energy saving heater. &ORVHGRRUVDQGZLQGRZV3URYLGHDGGLWLRQDOLQVXODWLRQRULQVWDOODKLJKHU wattage heater or multiple heaters if necessary. (If your circuit is rated for more capacity.) 5HSODFHKHDWHUDVVHPEO\ 2. A short circuit exists in the supply or heater wiring.* 2. Heat loss from room is greater than heater capacity.* 7KHUPRVWDWLVQRWIXQFWLRQLQJSURSHUO\ Heater discharges smoke or emits a burnt odor. 'XVWOLQWRURWKHUPDWWHUKDVDFFXPXlated inside heater. 2. Poor or loose electrical connections. &OHDQKHDWHU6HH³0$,17$,1,1*<285+($7(5´VHFWLRQIRULQVWUXFWLRQV 2.Turn off power at circuit breaker. Inspect all supply and heater wires for loose or poor connections. Secure or reconnect all loose connections. Do not reset circuit breaker until all connections have been checked or repaired. Element heats for 1. Defective motor or internal connection.* a moment without 2. Fan is jammed. WKHIDQWXUQLQJWKHQ immediately stops heating. 1. Heater or fan motor requires replacement. 5HPRYHREVWUXFWLRQDQGFRQ¿UPWKDWIDQLVVSLQQLQJIUHHO\3UHVVPDQXDOUHVHW WHPSHUDWXUHOLPLWEXWWRQSHUWKH³23(5$7,1*,16758&7,216´VHFWLRQ Heater does not run. 1. Thermostat is set too low. 1. Adjust thermostat to a higher temperature until heater operates (See Problem #6 if the problem persists). 3UHVVWKHPDQXDOUHVHWWHPSHUDWXUHOLPLWEXWWRQ6HH³23(5$7,1*,16758&7,216´VHFWLRQIRULQVWUXFWLRQV 4. Turn on the correct circuit breaker in the main disconnect panel. 7XUQRIISRZHUDWFLUFXLWEUHDNHU&KHFNVXSSO\ZLUHFRQWLQXLW\DQGSURSHUFRQnection to heater wires. 6. Repair or replace the heater assembly. &RUUHFWWKHFLUFXLWEUHDNHULQVWDOODWLRQ Heater continually trips the manual reset temperature limit control. 'XVWOLQWRURWKHUPDWWHUKDVDFFXPXlated inside heater. $LUÀRZLVEORFNHG +HDWHUKDVWULSSHGWKHPDQXDOUHVHW temperature limit. 4. Power not on at the circuit breaker. %URNHQRUSRRUO\FRQQHFWHGZLUHVWR heater. 6. Defective thermostat. &LUFXLWEUHDNHUQRWLQVWDOOHGFRUUHFWO\ )DQRUPRWRULVMDPPHG 4. None of the above. 3DJH &OHDQKHDWHU6HH³0$,17$,1,1*<285+($7(5´VHFWLRQIRULQVWUXFWLRQV 5HPRYHREVWUXFWLRQ0DLQWDLQDPLQLPXPGLVWDQFHRIôLQFKHVFPIURP DGMDFHQWVXUIDFHVòLQFKHVFPIURPWKHÀRRUDQGIHHWPIURP furniture or other objects placed directly in front of the heater. 5HPRYHREVWUXFWLRQDQGSUHVVKHDWHUPDQXDOUHVHWWHPSHUDWXUHOLPLWEXWWRQ 6HH³23(5$7,1*,16758&7,216´VHFWLRQIRULQVWUXFWLRQV 4. Replace heater assembly. &DGHW3ULQWHGLQ86$5HY