NovaLynx Corporation 4055 Grass Valley Highway, Suite 102 Auburn, CA 95602-9156,U.S.A. www.novalynx.com 110-WS-16 Modular Weather Station The Model 110-WS-16 Modular Weather Station is a computer-based meteorological system designed as a “user friendly” solution for data storage and real-time monitoring of weather conditions. Sensors & Accessories:• Wind Speed • Wind Direction • Air Temperature • Relative Humidity • Leaf wetness • Solar Radiation Sensor • Rain Gauge • Soil Moisture Sensor • Soil Temperature Sensor • Evaporation Gauge • Barometer • Data Logger • Wireless Spectrum Radio System • Tripod & Mast • Cables & Mounts • Solar Panel • windows based Graphical Display Software 110-WS-16 Modular Weather Station Additional sensor options include, water or soil temperature, rain gauge upgrade, evaporation, soil moisture, water level, gas detection, and others. The unique modular system design provides simple menu selections for adding or replacing sensors. The 110-WS-16D Data Acquisition Module features nonvolatile memory, selectable averaging intervals, 12 bit analog conversion, 0.1% F.S. accuracy, two alarm outputs, & optional modem communications. The WS-16 is supplied with an attractive desktop data acquisition module with a memory capacity of 640KB RAM. The standard system includes a 120Vac power adaptor and RS232 serial port for connection to a personal computer. For outdoor or remote applications, two enclosure options are available. One is for sites with AC power and the other utilizes a solar panel. Both options include a NEMA-4X enclosure and rechargeable battery to allow continued operation in the event of power failure. Data can be viewed using Windows Based Graphical Display Software. A one page real-time text display, an ASCII row and column format, or ALOHA format may be selected. A menu is provided for setting the date and time, alarms, logging interval, etc. Optional graphical display software is available for viewing real-time and historical data charts and graphs. DATALOGGER SPECIFICATIONS Specifications:Data Acquisition Module Reporting units: Selectable, °F, °C, mph, knots, m/s, km/hr Operating power: 10-16 Vdc Power consumption: 60 mA maximum, w/o power saver enabled < 5 mA, with power saver enabled Serial port: 9-pin d-sub connector, selectable baud rate, flow control Memory: 640 KB RAM, nonvolatile (225 days at 15 minute intervals ). Analog Inputs Number of channels: 7 voltage inputs, 3 inputs for 10K thermistor Input ranges: 100 mV, 1.0 V, 2.0 V, 5.0 V Accuracy: 0.1% F.S., 5 V range (-40 to 60 °C) Sample rate: 1 KHz maximum Resolution: 12 bit Digital Inputs/Outputs Frequency inputs: 3 counters, 16-bit each independent of 110-WS-16N Data Logger in NEMA-4X processor Enclosure Maximum count rate: 10 KHz Input modes: 2 high speed inputs for sine wave or square wave The unique modular system design provides anemometers, 1 input for contact closure rain gauges simple menu selections for adding or replacing Alarm outputs: 2 open collector @ 2 A max for high or low sensors. The 110-WS-16D Data Acquisition threshold events Module features nonvolatile memory, Serial Channels selectable averaging intervals, 12 bit analog RS232C port: 1 port with hardware and software conversion, 0.1% F.S. accuracy, two alarm handshaking, baud rates 110 bps to 56 Kbps, 9 pin d-sub outputs, and optional modem communications. connector The WS-16 is supplied with an attractive desktop data acquisition module with a memory capacity of 640KB RAM (approximately 225 days at 15 minute intervals with 6 sensors). The standard system includes a 120Vac power adaptor and RS232 serial port for connection to a personal computer. For outdoor or remote applications, two enclosure options are available. One is for sites with AC power and the other utilizes a solar panel. Both options include a NEMA-4X enclosure and rechargeable battery to allow continued operation in the event of power failure. Power Requirements Input voltage: +7 to 40 Vdc Operating current: < 55 mA @ 12 Vdc Power saver mode: .5 mA @ 12 Vdc Input protection: Fuse, surge protection, reverse polarity, and over-voltage Supply sources: Battery, solar power, unregulated DC Environmental Characteristics Operating temperature: -40 to 60 °C , Humidity: 0-90% RH non-condensing Timekeeping Format: MM/DD and HH:MM Accuracy: ± 30 seconds/month 110-WS-16STR Graphical Display Software The Model 110-WS-16STR Graphical Display Software is a Windows software program for data logger applications. It communicates with WS-16 data loggers for monitoring and display of sensors and devices. WS16STR includes the graphical design and terminal software runtime interface in one package. There are no limits on the number of loggers or sensor data points you can set or use. The standard Windows interface and setup tools make it easy to design new screens with graphs and indicators for your application. Data that has been stored in the WS-16 can be downloaded and the historical trend graph charts can be analyzed for daily or monthly highs and lows. With the optional HTML output, screens can be sent to a shared network drive on a timed basis, allowing anyone to view the various pages using an internet browser. Features include: • Real-time graphical software • Powerful data presentation • Supports real-time and stored archived data • Built-in terminal program, direct connect and dial-up • Scheduled automatic downloading • Can display minimum, maximum, averages, graphs, alarms, time of min-max, etc. • Calculated outputs, e.g. albedo, daily evaporation, delta temperature, etc. • Your own images can be added • Can be customized for special applications • All types of graphs, line, bar, area, 3-D • Full color and font support • Can easily be set-up and customized with a little typing and a few clicks of the mouse System requirements: • Runs on Windows 98/ME/XP/NT/2000 • Requires a minimum of 32MB RAM • For use with the WS-16 Data Logger