Cellex TubeTrace HTX ® ® Tubing Bundles HPT Power-Limiting Heating Cable TM Product Specifications Application . . . Freeze Protection 5°C. Suitable for steam service to 595°C. TubeTrace HTX is a pre-engineered electric traced tube bundle for steam sample lines and impulse lines to pressure transmitters. TubeTrace HTX will provide water freeze protection during -40°C 10 m/s wind conditions. HTX is suitable for superheat steam service temperatures up to 595°C. In the past, bundles subject to high temperature exposure were heat traced with series resistance mineral insulated (MI) heater cables that were custom made to length to fit each application. Measurement errors rendered bundles with MI heater cable unusable. TubeTrace HTX solves this problem with Thermon parallel resistance HPT heater cable. Bundles may be purchased in long rolls and “cut-to-length” into smaller sections in the field for any application. This minimizes waste and speeds up installation and engineering time. HPT is contained within TubeTrace with a “double layer thermal insulation system” that isolates it from extreme heat exposure. TubeTrace HTX bundles can be controlled with ambient sensing systems that turn heater cables on when outdoor conditions approach freezing. TubeTrace HTX bundles are designed to withstand 595°C superheat steam service even when power is applied to the heater cable during ambient conditions of 5°C, no wind. Ratings/Specifications . . . Watt density 33 W/m @ 10°C Supply voltages1 230 Vac Nominal Tube temperature Ambient controlled at 5°C Minimum ambient -40°C Superheat steam service temp. 595°C Bend radius 1 2 3 4 5 6 7 Construction . . . 1 Process Tube 2 High Temperature Woven Glass Fiber Thermal Insulation 3 Heat Reflective Layer 4 HPT Heater Cable 5 Thermal Diffusion Layer 6 Non-hygroscopic Glass Fiber 7 Polymer Outer Jacket 500 mm Note . . . 1. Higher voltages up to 480 Vac may be possible: contact Thermon for design assistance. 89 mm Product Features . . . THERMON . . . The Heat Tracing Specialists® www.thermon.com European Headquarters Boezemweg 25 2641 KG Pijnacker PO Box 205 2640 AE Pijnacker The Netherlands Phone: +31 (0) 15-36 15 370 Facsimile: +31 (0) 15-36 15 379 • • • • • “Cut-to-Length” • Suitable for Superheat Steam Service Temperatures to 595°C • Designed for Ambient Sensing Control • Will Freeze Protect in Low Ambient of -40°C Corporate Headquarters 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 U.S.A. Phone: +1 512-396-5801 Facsimile: +1 512-396-3627 • • • Cellex TubeTrace HTX ® ® HPT Power-Limiting Heating Cable TM Product Specifications Power Output Curves . . . Circuit Breaker Sizing and Type . . . The power outputs shown apply to cable installed on insulated metallic pipe (using the procedures outlined in IEEE Standard 515-1997) at the service voltages stated below. Power output will increase due to the thermal efficiency of TubeTrace. Maximum circuit lengths for various circuit breaker amperages are shown below. Circuit breaker sizing and earth-fault protection should be based on applicable local codes. For information on design and performance on other voltages, contact Thermon. Catalog Number 230 Vac Zone Length cm Power Output at 10ºC W/m H PT 10-2 61 28 Earth-fault protection of equipment should be provided for each branch circuit supplying electric heating equipment. Type B and C Circuit Breakers HPT at 230 Vac 230 Vac Service Voltage 60 Product Type Watts per Metre 50 40 H PT 10-2 30 20 Max. Circuit Length* vs. Breaker Size Metres Start-Up Temperature °C 10 0 -20 16 A 124 120 112 25 A 199 199 182 32 A 199 199 199 40 A 199 199 199 * Maximum circuit lengths shown are based on an instantaneous trip current characteristic per IEC 60898 at the referenced start-up temperature and a 10°C maintenance temperature. For maximum circuit lengths with other trip current characteristics contact Thermon. HPT 10-2 10 0 0 30 60 90 Pipe Temperature °C 150 120 How to Specify . . . SEI-6F1-53-1-ATPVC-1-HTX-M Bundle Type M or I SEI = Single Tube MEI = Multiple Tubes Process Tube O.D. Process Tube Material 2 = 1/4" A = 316 SS Welded Metric or Imperial Indication 1 High Temperature 3 = 3/8" As = 316 Ti SS Welded 4 = 1/2" D = Monel 2 Number of Tubes 6 = 6 mm E = Titanium 1 10 = 10 mm F = 316 SS Seamless 2 12 = 12 mm Fs = 316 Ti SS Seamless G = 304 SS Welded H = 304 SS Seamless HTX = 595°C Continuous Heater Cable Option 1 = BN Nickel Plated Braid 7 = OJ/Fluoropolymer Heater Cable Type Jacket Option Type Process Tube Wall Thickness 035 = .035" ATPVC 3 049 = .049" PE 065 = .065" TPU 53 = HPT 10-2 (28 W/m) @ 230V 1 = 1 mm 1.5 = 1.5 mm J = Hastaloy C276 K = Inconel 825 Notes . . . R = 316H SS Seamless 1. Seamless tubing has a standard quality K3, other qualities are available on special request. Tubing meets the ASTM standards, tubing that meets DIN standards is available on special request. X = Special 2. Monel and Inconel are trademarks of Inco Alloys International, Inc. Heating Cable Certifications/Approvals . . . 3. Black ATPVC is standard, other jacket materials are available. ATPVC is similar to PVC with improved low temperature flexibility. European Organisation for Electrotechnical Standardisation Hazardous (Classified) Locations II 2 G/D EEx e T2 to T6 02 ATEX 012337X Factory Mutual Research Hazardous (Classified) Locations HPT has additional hazardous area approvals including: • DNV • Lloyd’s • SAA • JIS • CCE/CMRS Underwriters Laboratories Inc. Hazardous (Classified) Locations Contact Thermon for additional approvals and specific information. Form CLX0018U-0403 © Thermon Manufacturing Co. Printed in U.S.A.