ArcSystem D4 Driver CC Control Project Type Catalogue Number Technical Data Sheet The D4 Driver forms part of the ArcSystem range of drivers for controlling ArcSystem 1 cell, MR16 LED fittings and almost all third party LED product. It is Constant current driver. A Constant voltage version is available known as the CV range, please refer to separate data sheet. It creates a 100% to absolute zero dimming using wired DMX or wireless ArcMesh protocol. Technical Datasheet. The information and designs contained within this document are the sole ownership of Global Design Solutions Limited. All descriptions represent only particulars of the design and do not form any contract. Global Design Solutions (GDS) reserves the right to change the specification without prior notification Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 2 General Information A compact convention cooled LED driver delivering accurate dimming to absolute zero. The driver has RJ45 in/out connections for local DMX and comes complete with wireless capability for control using the ArcMesh wireless protocol. The D4 driver can run up to 8 x GDS MR16 or 4 x GDS pro/décor 1 cell fittings. Refer to the light fitting datasheets for connection information. The ArcSystem has been specifically developed for auditorium lighting applications where high quality extremely accurate, consistent and smooth dimming is required. The use of onboard Device Management allows the D4 driver to be addressed remotely using the ARCMCT (commissioning tool) with the ARCMTX1 (Wireless Gateway) ensuring installation is fast and simple for electrical contractors. Key Points: Wired DMX and Wireless (ArcMesh) Addressing is achieved using the wireless gateway and commissioning tool. Step less smooth dimming to absolute zero. Universal Mains input = 90-264VAC 50/60Hz Full load power output = 108Watts (when driving at 45VDC) Output Current = 400/600mA Output Voltage = 18-45VDC MAX per channel Control Channels (4 Channels, wired DMX) NOTE: Only 3 control channels are available with ArcMesh, 4 channels available through wired DMX, Please refer further in this data sheet. Standby power = <1W Inrush Current = 120A max Max ambient operational temperature = 40°C Convection Cooled, Silent operation High Frequency Dimming Control (flicker free) Compliant with Part L of building regulations and proposed efficiency levels for energy saving incentives (UK) Note: If Using driver type ‘RDM wired only’, an RDM programmer can be used such as the Enttec RDM USB Pro for setting DMX addresses and other parameters. D4 driver CC - Non Emergency If using the standard wireless ArcMesh driver, the driver has to be used in conjunction with a gateway and commissioning tool even if only wired DMX is used (RDM is not supported currently in the wireless driver version). Please contact GDS for further information and updates. To specify state: A high performance LED driver having 100% to absolute zero dimming, controllable from local DMX or ArcMesh wireless protocol. Designed for 4 x GDS pro or décor 1 cell units, or 8 x GDS MR16 LED units, the driver will deliver 18-45VDC, have 400/600mA adjustment and have a total power delivery of over 100W. The driver will be constructed from powder coated mild steel with conduit knockouts and be designed for wall fixing with all connections enclosed. The DMX data will connect using internal neutrik RJ45 sockets and be complete with a through option for linking DMX data. The driver will be silent in operation and convection cooled. Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 3 Options Matrix Part Number Description ARCMD4ACC D4 Driver, Non Emergency [ArcMesh] ARCMD4ACCE D4 Driver, Emergency (Dual Input) [ArcMesh] ARCMD4WCC D4 Driver, RDM Wired Only ARCMD4WCCE D4 Driver, RDM Wired Only, Emergency Note. These part numbers are for the constant current version, for constant voltage drivers please refer to separate data sheet. Cable Adapter Kit The channel outputs from the D4 CC are 2 pole phoenix screw connectors that accept ferruled singles. A cable adapter kit allows use of the standard ArcSystem 4 pole connector system. This kit allows for standard 1 cell downlights to connect directly to the driver, or use the extension leads below. D4 Output Screw Terminals Part Number Description ARCD4CK D4 Cable Adapter Kit D4 Cable Kit Accessories Extension Cables. Used between the driver and the pro range/decor 1 cell light fitting MR16 Y Split Adaptor Used between the driver and 2x MR16 light fittings. This splitter connects both MR16s in series for use on one channel. Part Number Description ARCDAHBC1 1M Extension Cable ARCDAHBC2 2M Extension Cable ARCDAHBC3 3M Extension Cable ARCDAHBC5 5M Extension Cable ARCDAHBC10 10M Extension Cable ARCDAMYSA MR16 Y Split Adaptor Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Extension Lead Splitter Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 4 DMX Connectivity DMX Connection Inside the enclosure there are 2 x RJ45 sockets for termination of standard RJ45 plugs, in and thru. This allows for easy DMX termination, testing and commissioning. Standard patch leads can also be used for interconnects as required. DMX RJ45 Pinout 1 2 7 8 Data + Data GND GND Indications are presented as follows: Status (top)—processor running Link (bottom)—Arcmesh linked or DMX data ok. Connectivity Overview 230VAC, Main input Standard Driver ARCMD4ACC ARCMD4WCC DMX, RJ45 link through (thru) DMX, RJ45 input (in) 230VAC, Sense Input (local non maintained input) 230VAC, Main input (maintained input from battery system) Emergency Driver ARCMD4ACCE ARCMD4WCCE DMX, RJ45 link through (thru) DMX, RJ45 input (in) LED Channel Outputs Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 5 Non Emergency Connection Non Emergency D4 drivers have 1 x mains connection. This connects to a normal mains supply and in the event of power failure the driver will naturally turn off as there is now no power. However, the driver can be set to recall a level in the event of losing a wireless or DMX signal using the commissioning tool options. Supply Input 90-264VAC 50/60Hz D4 Driver Emergency Connection Emergency D4 drivers have 2 x mains leads connections, these have the following functions: 1. 2. Mains sense Maintained supply Note: Input 2 (Maintained supply) circuit must be wired in fire rated cable to the driver connection point. Please consult with a qualified electrical engineer for correct installation procedures. 1 2 90-264VAC 50/60Hz 90-264VAC 50/60Hz Sense Input D4 Driver Maintained Input Note: For reliable emergency operation, when the mains sense input power is lost, the driver will bypass all electronic processing from the wireless/DMX system. The mains sense is used to detect whether the power has been lost. This will force the light fitting to a full on state running from the maintained supply. There is no control of the light fitting from the Wireless or DMX until the Mains sense input is turned back on. This configuration will be sufficient for a central battery system that provides a maintained supply at input 2 regardless of whether power has been lost or not. If the central battery system only provides power upon mains failure at input 2, a change over relay will be required to switch the maintained input from a normal supply over to the battery system. This is required as the light fitting always requires power at the maintained input for correct operation. In this case, please see the information below. Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 6 Emergency Connection - Cont The below example shows a typical changeover relay (Cooper Controls ACM1) being used to ensure the driver always has constant power at the maintained input ensuring correct operation. This is required if the central battery system does not provide power in normal operating conditions. Supplies D4 Driver Light Fitting Please see ACM1 manufacturers Appendix at the end of this specification sheet. Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 7 Pro 1 cell and MR16 Connection Examples X4 X8 Pro 1 Cell/Decor The D4CC can drive 4 x 1 cell downlights. MR16 The D4CC can drive 8 x MR16 units using the splitter described above. Channel Current Select Warning! Do NOT attempt to carry out the following procedures unless authorised to do so. Always ensure power is isolated prior to commencing any setting changes. If in doubt, please contact your supplier or GDS directly. Each channel of the driver will produce 600mA constant current output (standard GDS 1 Cell Décor/Pro Cell operation) when not in ‘Low Select’ mode. When in low select mode the driver will deliver 400mA. Dip switch 1 selects between the drive currents, ON is the lower 400mA setting, OFF is the higher 600mA setting. If using GDS MR16 fixtures, the ‘Low current Select’ MUST be enabled otherwise damage to the GDS MR16 fitting will result with either one or two units connected to a channel. Channel DIP Switches Location of each channel DIP switch blocks Current Select, DIP Switch 1 OFF = 600mA ON = 400mA Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 8 Driver Board DIP Switch Settings There are a number of other control options which can be changed within the driver. There is a DIP switch block per output channel. The options are as follows in order of switch positions: 1. [400/600mA] OFF=600mA, ON=400mA Adjustment of drive current for this channel. This is always set to off when this driver is used in a 4 cell fitting, as described above. 2. 3. 4. [PWM Ch.1] OFF=No response to Channel 1 ON=Responds to Channel 1 [PWM Ch.2] OFF=No response to Channel 2 ON=Responds to Channel 2 [PWM Ch.3] OFF=No response to Channel 3 ON=Responds to Channel 3 The PWM channel switches select which control channel will drive this output on the driver card. As an example, if PWM Ch.1 is set to ON for an output, then this will respond to channel 1 DMX address in the device configuration, see example below: This is a screen shot taken from the Commissioning tool software. In this example, the channel DMX data will be 1, 5 and 10 respectively. If the Driver card channel is selected to PWM 2, the cell will respond to DMX 5. If there are more than 1 DIP switches selected ON, the driver card will listen to the highest level of all the selected channels. It will operate on an HTP (Highest Takes Precedence) basis. The ability to have more than one DMX channel within a D4 driver means each channel can be allocated a DMX address enabling different level control. For further information on Commissioning ArcSystem products please refer to the ARCMCT help file. 5. [OVERRIDE] OFF=Cell will not light in emergency state, ON=Cell will light in emergency state. Refers to how each cell behaves when the mains sense input is turned off, and the fitting goes into emergency override. Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 9 3 and 4 Channel Modes Each D4 driver has 4 output channels that can be connected to a number of control channels via the DIP switches as described above. D4 drivers under Wireless ArcMesh control have 3 individually addressable channels. The 4th channel will need to have the same address as one of the other 3 output channels. Example: Output 1 set to control channel 1 Output 2 set to control channel 2 Output 3 set to control channel 3 Output 4 set to control channel 1,2,3 (DIP switch set to 1) (DIP switch set to 2) (DIP switch set to 3) (depending on DIP switch setting) Currently, only wired RDM versions of the D4 driver can be individually addressed on all 4 channels, IE have 4 separate control channels. To obtain control channel 4, the emergency override DIP switch is used. Example: Output 1 set to control channel 1 Output 2 set to control channel 2 Output 3 set to control channel 3 Output 4 set to control channel 4 (DIP switch set to 1) (DIP switch set to 2) (DIP switch set to 3) (Emergency override set to on) Override Input When using a wired RDM driver that requires the 4th control channel, the override header needs to be shorted using the shorting plug provided with the driver. NOTE If the driver is an emergency version, regardless of driver type, there will only be 3 control channels available, as the 4th control channel is used to activate the emergency control on the selected outputs of the driver, using the DIP switch settings on each output. Please see our commissioning technical bulletins for more details on multiple channel addressing. Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 10 Control using ArcMesh If using wireless control with the D4 driver, a wireless gateway will be required, part number ARCMTX1. When using the wireless control option, the system can be configured using the software and USB dongle (ARCMCT). In this case, DMX is connected to the gateway and then the fittings are controlled wirelessly. The ARCMTX1 allows for other settings to be configured as listed below: Patching of groups of light fittings to DMX channels. Minimum and maximum dimming levels per group Power fail/recovery options per group Pre set recall when using button panels such as the ARCMCP8 If using the wired control option, DMX can be wired directly to the D4 driver using RJ45 connectors. Each driver has IN and THRU options, using 2 separate connectors. The commissioning tool along with the gateway allows for addressing of each driver remotely. CT Tool D4 Driver D4 Driver Wireless Gateway AC Mains Power 90-264VAC Dimmer and other wired Fittings DMX out Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 DMX512 From Lighting console AUX Input DMX In Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 11 RDM Control Commissioning For Wired Only RDM drivers, each unit can be connected using the RJ45 IN and THRU connectors with a maximum of 30 drivers on one DMX line. An RDM compliant DMX Buffer can be used if more DMX Lines are needed. Connecting the RDM programmer to the DMX input of the buffer will allow you to identify and change driver settings In the RDM Controller Software. We recommend using an Enttec RDM Controller and software. For more information on this see or RDM commissioning Technical Bulletin. Laptop running RDM software RDM Programmer RDM Buffer D4 Drivers The RDM Controller software and programmer can be found at: https://www.enttec.com Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 12 Dimensional Data - D4 CC Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 13 Appendix 1 - ACM1 Manufacturers Data (Cooper Controls) Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 14 Appendix 1 - ACM1 Manufacturers Data (Cooper Controls) - Continued Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 15 Appendix 1 - ACM1 Manufacturers Data (Cooper Controls) - Continued Important - Please Read Global Design Solutions (GDS) cannot be held responsible for incorrect information from third parties such as datasheets and schematics added as appendixes to the ArcSystem data Sheets. This third party information is added to aid the reader only. Do not assume this information is accurate. It is advised the relevant company is contacted to ensure up to date correct information be obtained. Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6 ArcSystem D4 Driver CC Technical Data Sheet Page 16 Global Design Solutions Limited www.gds.uk.com Vat No. 8271985 96 Reg Number 508 6550 Tel: +44 (0) 1173250063 Sales: [email protected] Riverside Business Park St Annes Road Bristol BS4 4ED Version 6