Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Hoffman |Controls 708-BVmA and 708-CVmA Series Electronic Fan Speed Controllers Product Data Application The variable speed Controller is used for adjustment of motor RPM within a limited range of operating temperatures that assure adequate ventilation of the motor. Motors should always be evaluated at minimum reduced speed at the highest ambient operating temperature anticipated. The Controller is designed for air moving applications using squirrel cage or propeller type fans. However, it may be suitable for other, non air-moving, direct drive motor applications. Motors should be open, drip-proof types. 708-BVmA Series Electronic Fan Speed Controller The Controller heat sink is designed to operate in ambient temperatures up to 120° F. The component housing should be enclosed inside an electrical box or wiring compartment. The Controllers should not be mounted in an airtight, unventilated panel or on a heat producing surface. The Controller should be mounted to electrically conductive material and/or be electrically grounded. Description Squirrel Cage The NEW 708-BVmA and 708-CVmA Series electronic Controllers are designed to provide proportional speed control of single phase motors for variable air volume applications. The Controller may be used with shaded pole or permanent split capacitor type motors from 120V to 480VAC. Propeller (blade type) The Controller phase proportions (modulates) the single phase power to regulate RPM as determined by a 2 – 10V DC or 4 – 20mA DC input signal provided by the customer. The 708-BVmA and 708-CVmA Series Controllers provide independent “maximum” and “minimum” speed limit adjustments. Also included, a separate continuous minimum speed or “drop out” function at minimum input. Variable Air Volume controls offer the optimum flow of air for the prevailing loads encountered. VAV provides maximum flow for effectively accomplishing sensible heat loads at design conditions. Minimum flow occurs when lighter loads are encountered. In the cooling mode, an added benefit can be obtained. As air flow decreases with load, additional latent cooling capacity is utilized to provide extra dehumidification. This function is most beneficial when light loads are experienced and increased dehumidification is required. Page 1 of 2 Features and Benefits • Applicable for shaded pole or permanent split capacitor motors. • Multi-voltage applications. • Minimum/Maximum speed adjustments. • Motor cut-out adjustment. • Optional 265-PI Interface (Proportional Integration). – Shown in Product Illustration. 708-BVmA & 708-CVmA Product Data Specifications Full Speed Line 15% ≈ 24VAC Frequency 60 Hz Voltage, Line (nominal) 120 – 480VAC Current (maximum) 708-BVmA 708-CVmA Recommended Operating Range (Full Speed to 50% of 90%) Good Speed Regulation 10 Amps 15 Amps To rq ue 1.0 VA 90% Motor Speed (RPM) Power ≈ 85% Volts Voltage, Input (nominal) RMS Voltage Reduction effects ≈10% RPM Reduction nt re ur C 50% Potential Operating Range (50% to 30% of full speed) Good Speed Regulation Possible ≈ 30% Not Recommended Operating Range Motor Typically Stalls Input Signals DC Volts Load Impeadance DC milliAmps Load 2 – 10V DC 10,000 Ohms Min. 4 – 20 mA DC 500 Ohms Stall ≈ 30% Current Torque Min. Operating Ambient FLA ≈ 135% of FLA Max. 32°F to 120°F Humidity Typical Motor Volts / RPM vs. Current / Torque Non-condensing Dimensions (L x W x H) 5.52” x 4.15” x 3.15” 4 – 20mA DC Volts / mA inputs when optional 265-PI Interface is not installed 2 – 10VDC ! 24V AC J1 J9 J8 265-PI Interface RA J4 GND 24V AC PI H1 DA Grounded secondary (if applicable) MAX TP1 Jumper either RA or DA as applicable TB3 YEL/4–20 R6 BLK / GND AS RED / 2–10 R4 TB2 TIME CONST ADJ. +12 SETPOINT ADJ. TB1 OS J2 R17 CUTOFF CAUTION MIN ! mA in J3 R28 R23 Transformer primary must be connected to same power line as motor / Controller (L1 – L2). Vin 4 – 20mA DC J2 0 – 10V DC GND TP1 J1 Transducer / Aux Equipment Power LINE +12V LOAD P2 P1 J4 J6 J7 J3 LOAD L1 Motor 120V AC 208V AC 230V AC 277V AC 460V AC 480VAC LINE L2 or Neutral 708-BVmA and 708-CVmA Series Product Illustration with Optional 265-PI Interface Installed Hoffman|Controls 2463 Merrell Road, Dallas, Texas 75229 • Phone: (972) 243-7425 • Fax: (972) 247-8674 • Toll Free: 1-888-HCC-1190 www.hoffmancontrols.com Page 2 of 2 Form: 708-BVmA/708-CVmA 0602-020, Rev. A