[preliminary design data] TC 201 Advanced Trigger Unit TC 201 TO 255! Tactical Controls Tactical Controls Scale (mm) 0 35mm Tactical Controls Features Special Design for Networking Capability Digital Remote Control Local Analogue Control Windows Based Software Available Fully Isolated Protected Inputs Auxiliary 5V Supply Internal Supply Conforms to UL, CSA and VDE Requirements Short-circiut Protected High Specification Easy to Use and Install © Tactical Controls Limited Unit 4, Parkland Business Centre, Chartwell Road, Lancing, West Sussex, BN15 8UE Tel: 01903-750800 Fax: 01903-750678 Email: [email protected] page 1 of 4 General Description TC201 is one of the new generation of Intelligent Communication Thyristor PhaseAngle Trigger Modules. Using the RS485 communication link via any standard PC, up to 254 separate loads can be controlled. Each load can have up to 1024 control levels of resolution. Alternatively, each thyristor controlled load can be varied by an externally connected potentiometer, providing a variable 0-5Vdc analogue input to the TC201. When the 05Vdc I/P terminal of the TC201 is switched to the wiper of an external potentiometer, the 05Vdc I/P input will automatically over-ride the phase-angle trigger level from the RS485 Communication Up to 255 trigger units can be connected Windows Based Software Available The TC201 supports digital communication based on RS485 multi-slave bus configuration using two wires. The bus master is usually a PC with a serial RS485 communication port. Each TC201 connected to the RS485 bus acquires a unique address from the bus master during the setup phase. The addressing scheme allows a maximum of 255 units to be connected on the same bus. The communication protocol supports various commands that allow each TC201 output level to be set by the master, status interrogation, or change of configuration. The following commands are supported: Level: The output level of the TC201 can be set by the master between 0 to 1023. Status: 50/60Hz - the mains frequency detected. local/remote - local if the analogue I/P is connected. softstart cycle - the number of cycles used to ramp the output from 0 to setpoint during power up or when the zero crossing pulse is re-established. The range is 0 to 100 cycles. setpoint filter - (0 to 10) the number of cycles used to filter the setpoint step changes. Configuration: softstart cycle - the number of cycles used to ramp the output from 0 to setpoint during power up or when the zero crossing pulse is re-established. The range is 0 to 100 cycles. setpoint filter - (0 to 10) the number of cycles used to filter the setpoint step changes. © Tactical Controls Limited Unit 4, Parkland Business Centre, Chartwell Road, Lancing, West Sussex, BN15 8UE Tel: 01903-750800 Fax: 01903-750678 Email: [email protected] page 2 of 4 Specification Technical Specification Operating Supply Voltage . . . . . . . . . . . . . . . . Operating Frequency . . . . . . . . . . . . . . . . . . . Nominal +10%, -15% 45-65 Hz Peak Gate Output Current . . . . . . . . . . . . . . . Critical dv/dt . . . . . . . . . . . . . . . . . . . . . . . . . . .................................... Reference Output Aux. Voltage . . . . . . . . . . . Input/Output Isolation . . . . . . . . . . . . . . . . . . . 1.9A @ Vs=max @ 90 degrees 500V/uS min for 240V type 100V/uS min for 440V type 5V @ 10mA minimum 2.5kV rms Analogue Control Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-5V dc 100K ohm min Digital Communication . . . . . . . . . . . . . . . . . . RS 485 Commissioning Input Voltage . . . . . . . . . . . . . 5V dc to enable; open to disable Mechanical Specification Storage Temperature . . . . . . . . . . . . . . . . . . . Operating Temperature . . . . . . . . . . . . . . . . . . Humidity Level . . . . . . . . . . . . . . . . . . . . . . . . Flame Retardant Specification . . . . . . . . . . . . Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware Supplied . . . . . . . . . . . . . . . . . . . . . -40 C to +125 C 0 to +55 C 80% RH UL94-V0 320 g 100mm (diagonal), 2Nm torque 2 x M5 Mounting Screws Tactical Controls 80mm 92mm 33mm Communication Specification Levels Supported . . . . . . . . . . . . . . . . . . . . . . 0-1023 Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz, local/remote Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . Softstart: 0-100 cycles Setpoint filter: 0 - 10 cycles Address: 1-255 © Tactical Controls Limited Unit 4, Parkland Business Centre, Chartwell Road, Lancing, West Sussex, BN15 8UE Tel: 01903-750800 Fax: 01903-750678 Email: [email protected] page 3 of 4 Typical Network Configuration Upto 255 Trigger Units A RS485 B See below for load connection A SETUP +5v Press to setup I/P 0v ANALOGUE B SET-UP +5 I/P 0V Controls AC to DC Control +VE G1 A B SETUP A A1 TH1 LOAD B +5v I/P 0v G2 SET-UP TH2 +5 A2 F2 HRC FUSE I/P 0V -VE Controls F1 0.5A N/ ~ L/ Main AC Supply AC to AC Control TH2 A2 A B SETUP G2 LOAD A B +5v I/P 0v TH1 SET-UP A1 +5 G1 F2 HRC FUSE I/P 0V Controls F1 0.5A N/ ~ L/ Main AC Supply Copyright (C) 2000 Tactical Controls Limited This document contains proprietary information which is protected by copyright. All rights reserved. This documen t or parts thereof may not be reproduced in any form without written permission of the publishers. The information in this document is subject to change withoutnotice and should not be construed as a commitment by Tactical Controls Limited. Tactical Controls Limited shall not be liable for errors contained hereinor for incidental or consequential damages in connection with the furnishing, performance or use of this material. Document information: TC201 data-sheet version 2.2 (18/01/01) © Tactical Controls Limited Unit 4, Parkland Business Centre, Chartwell Road, Lancing, West Sussex, BN15 8UE Tel: 01903-750800 Fax: 01903-750678 Email: [email protected] page 4 of 4