* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download CSPD - Chip Surge Protection Devices
Integrating ADC wikipedia , lookup
Nanofluidic circuitry wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Operational amplifier wikipedia , lookup
Josephson voltage standard wikipedia , lookup
Schmitt trigger wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Current source wikipedia , lookup
Opto-isolator wikipedia , lookup
Power electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Current mirror wikipedia , lookup
Voltage regulator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
CSPD(Chip-SPD) SMD TYPE Over Voltage Protection Device Seems Similar, But Exactly Different SFI Electronics Technology Inc. What is CSPD ? CSPD (Chip Surge Protection Device) is a kind of surface mount surge voltage protector. SFI utilized exclusive powder material and product technology to develop a creative new concept . We also get many patents from many countries, including the ”A” innovation patent (Material Composition Having core-Shell microstructure used for Varistor) and ”B” innovation patent (Surge Absorbing Material with Dual Function ). That’s why CSPD has the better non-linear ohm with higher withstanding peak current compared to conventions [Description]: The non-linear impedance of ceramic comes from Schottky barrier between two piece of ZnO particles (double Schottky barrier). It means, in sintering process of ZnO , it also realizes the semi-conductive of ZnO particle and makes the grain boundary more tight. (Fig. (1) & (2)) CSPD peak current protection mode as below. Fig. (1) Fig. (2) “” Conventional “” process VS. “” CSPD “”process (1) 、Mixture of ZnO: Convention: At same sintering process, 1.The ZnO particle becomes ion mixture and increase semi-conductive. 2.Forming the boundary of covering ZnO particles. (2) 、Distribution of boundary: CSPD: The ZnO mixture and covering and the high impedance materials of particle are divided to two individual process (innovation) and ZnO particle mixture to make more semi-conductive. Convention: If the particle of ZnO is too rough and few, it’s difficult to cover on surface evenly. The result will make the high resistance of Bi2O3 not evenly and affect dispersion higher, alpha value lower, clamping voltage higher and affect functions of varistor. CSPD: The product is made by nanotech process and makes the boundary grains in nano to make a chemical compound. It makes the boundary cover the ZnO evenly and makes each double Schottky barrier more higher and even the same height, the function more concentrative, dispersion lower, higher alpha, low clamping voltage. The functions of varistors is upgraded. (3)、Additional PTC: Convention: The product has one feature: the non-linear α value will go down rapidly and the leakage current will exceed 100μA when the temperature rises. It’s the weakness. CSPD: To add PTC factors between boundary ,the resistance of PTC will become large when the temperature rises. Within a range of temperature, the resistance increases 102 ~108 times rapidly. It upgrades the operation temperature of CSPD. Advantages 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Micro Package Size (SMD ) type: to achieve large space and solve height Limit High Surge Current: Stand 10X700uS 6KV Surge Low BDV: 12V can provide the best solution for protective systems High reliability: Low leakage after high reliability Low Clamping Electric Distribution Concentricity High Non-linear α Value: Over 25 and it will upgrade IV curve sensitivity Quick respond Time: Solve the problem “extinguish” of GDT High performance: Many times surge sparks over 30 times on waveform 10/700us Good Temperature Features : With operating range -55 ℃~125 ℃ New product Content( CSPD Family) : Type Transient Load Dump Series New Design ESD Standard Remark Auto Power ISO7637-2 Pulse 5 Load Dump 80J Can replace TVS ,MOV SHC Industrial Control IEC61000-4-5 Surge Current: 3000A(8x20 us) Can replace MOV , MLV SHN Network Security IEC61000-4-5 K21 Surge Voltage: 6KV (10X700 uS) Can replace GDT, Sidactor SHV Power IEC61000-4-5 Breakdown Voltage: 470V / Surge: 800A Can replace MOV, GDT SEA Auto CAN BUS ISO10650 ISO7637-2 Pulse 1, 2, 3 ESD 30KV Available SEM Mobile Clamping Voltage <12.5V Under Developing Breakdown voltage : 100V / Cap. 0.05pF Under Developing IEC61000-4-2 Dual Function Max. value parameter SHA Enhance Surge Main Application SEC Ultra High Speed ESD+EMI SML I/O port (CSPD+Inductor) IEC61000-4-2 ESD: 8KV EMI : 300M Hz Available Surge +Current Limited SMP Power (CSPD+PTC) IEC61000-4-5 Fail mode at open circuit Under Developing SMC Power (CSPD+E-cap) IEC61000-4-5 Breakdown Voltage: 270~470V Cap: 1uF~4.7uF Under Developing Surge+EMI CSPD MOV GDT TVS Sidactor The Comparison Table Type SFI CSPD MLV TVS MOV GDT 5V~470V Low 100A~3000A -55℃~150 ℃ 1.5J~ 50J Low Low 5V~100V Low 20A~1200A -45℃~125 ℃ 12J~25J Low Low 5V~100V Low N.D. -45℃~125 ℃ N.D. Low Low 18V~1800V High 250A~10000A -45℃~125 ℃ 12J~50J High High 75V~6KV High 2KA~15KA -45℃~125 ℃ N.D. Low Low <0.5ns Yes Yes Bi-Direction <0.5ns Yes Yes second Bi-Direction <0.5ns Yes No primary side/ second Single Direction <10ns No Yes primary Bi-Direction <50ns No Yes Primary Bi-Direction >10 Times <0.5ns No High <0.5ns Yes Low <0.5ns No High <10ns Yes High <50ns No No No No No No No N0 No Yes No Yes No Yes No No Electric Functions Operating Volt. Clamping Volt. Surge Current Operating Temp. Load Dump (J) Leakage Current Inductance Effective Applications Functions Response Time ESD Protection Surge Protection Design Position Polarity Reliability Sparks Response Time Degradation Potential Issues Extinguish Explosion Temperatue Derating Our Patents Primary side/ Second SFI is a professional manufacturer with the ability to produce various overvoltage protection devices . The excellent ability of innovation makes the new products own more and better electric functions compared to competitors. Normal SMD size 2220 , Surge is 1200A GDT, bigger size and higher operation voltage can reach above 200V, SFI –SHN series with ”high surge and low clamping votlage” can stand : 1210/ 47V~75V/ 4KV~6KV(10x700us) 1206/ 12V / 4KV~6KV(10x700us) SFI-SHC (High Current Series) is 2220/ 24V~75V/ 3000A (8x20us) 1812/ 24V~75V/ 2000A (8x20us) 1210/ 24V~75V/ 1000A (8x20us) 1206/ 24V~75V/ 500A (8x20us) Higher surge ability more than 2~3 times compared to other products Higher Surge , lower clamping voltage , more protection SHC SHN CSPD SHV Higher voltage compared to conventional SMD Type SHA Higher Load Dump ability more than one time SMD 3220 , Surge max value is 500A SMD 2220 ,Load Dump max is 25J, SFI –SHV (High Voltage Series) can stand : 3220 / 470V / 800A 2220 / 470V / 500A~800A 1812/ 300V / 500A 1210/ 150V~220V/ 500A SFI-SHA(Automotive) can stand 80J, and with various models : 3220 / 24V~47V/80J 2220 / 24V~47V/50J 1812/ 24V~47V/ 20J 1210/ 24V~47V/ 12J 1206/ 24V~47V/ 6J 0805/ 24V~47V/ 1.5J Remarks : SHV Series is UL approval SFI 1812 SC 240 Logo Size Series Breakdown voltage (V) SFI 1206 1210 1812 2220 SHC 12 24 47 75 1210 SN 750 Breakdown voltage (V) SFI Logo Size Series SFI 1206 1210 SHN SFI 2220 SV 431 Logo Size Series Breakdown voltage (V) SFI 1210 1812 2220 3220 SHV 391=39X10 431=43X10 471=47X10 SFI 2220 SA 240 Breakdown voltage (V) Logo Size Series SFI 0805 1206 1210 1812 2220 3220 SHA - - A Surge Current (8x20 us) Inner Code 501=500 102=1000 202=2000 302=3000 - - 120=12V 470=47V 750=75V 24 36 47 102 060 K Surge Voltage (10x700us) Inner Code 060=6KV 040=4KV - - 501 A Surge Current (8x20us) Inner Code 201=20X10 501=50X10 801=80X10 - - 250 J Load Dump (J) Inner Code 1R5=1.5J 030=3J 060=6J 090=9J 120=12J 250=25J 500=50J 800=80J SHC Series Description This series has the Highest Transient Current and Energy Absorption The construction and technical makes the products to stand ultra high transient current and high energy absorption. The size 0805 can stand over 250A in waveform 8/20us and the size 2220 can stand 6500A in some special size . Therefore, under the same current and energy conditions, the size of SUPER Series is much smaller than other products. The sparks can be over 10 times in order to make sure the surge ability. In the global market, the protection components reach such high current ability products only the disk type, we use the high professional technical ability for the multilayer technology to provide higher products at the small size. To compare the market MLV series products, new SHC Series upgrade the current ability and also to show the higher product characteristic than all the OVP products Features 1. 2. 3. 4. 5. 6. Application Ultra high current handle ability , up to 6500A Several Surge Voltageand Surge Current ability. Breakdown Voltage Concentration ratio higher 99.5% High nonlinear exponent α up to 50 Ultra low leakage current < 5 uA Ultra high temperature up to 125 degree 1. Telecom equipment RJ45/LAN connector 2. Outdoor/ Indoor AP/ IAD 3. Security system IP CAM 4. Base station 5. Low voltage power line SHC Series Specification Part No. Size Working Voltage Breakdown Voltage Clamping Voltage Leakage Current Surge Current SFI1206SC120-501A 1206 DC 9V 12V <25V 10 uA 500A SFI1206SC240-501A 1206 DC 18V 24V <47V 10 uA 500A SFI1206SC470-501A 1206 DC 38V 47V <75V 5 uA 500A SFI1206SC750-501A 1206 DC 60V 75V <100V 10 uA 500A SFI1210SC120-102A 1210 DC 9V 12V <25V 15 uA 1000A SFI1210SC240-102A 1210 DC 18V 24V <47V 15 uA 1000A SFI1210SC470-102A 1210 DC 38V 47V <75V 10 uA 1000A SFI1210SC750-102A 1210 DC 60V 75V <100V 10 uA 1000A SFI1812SC240-202A 1812 DC 18V 24V <47V 15 uA 2000A SFI1812SC470-202A 1812 DC 38V 47V <75V 15 uA 2000A SFI1812SC750-202A 1812 DC 60V 75V <100V 15 uA 2000A SFI2220SC240-302A 2220 DC 18V 24V <47V 15 uA 3000A SFI2220SC470-302A 2220 DC 38V 47V <75V 15 uA 3000A SFI2220SC560-302A 2220 DC 60V 56V <90V 15 uA 3000A SFI2220SC750-302A 2220 DC 60V 75V <100V 15 uA 3000A SFI2220SC820-302A 2220 DC 65V 82V <135V 15 uA 3000A SHN Series Description Telecom systems are all connected by ethernet. The surge suppressors can pass the overvoltage to earth and clamping the voltage to a level acceptable to the systems. Since the standard of 100/1000M of Ethernet speed, these precise devices and connectors can be subject to voltage shocks. These series are design for this ethernet and telecom application and best surge protection for the circuit for these with the high performance. Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Application SMD type to save space (1206 & 1210) Pass 10/700 us/ 40ohm surge 6KV test Lower clamping voltage than GDT Faster response time < 0.5 ns than GDT & Sidactor No extinguish problem Bi-directional Surge strike ability over 30 times Wide operation temperature - 55 ~ +125°C Ultra low leakage current < 1 uA 1.Telecom equipment RJ45/Lan connector / Ethernet 2. Outdoor/ Indoor AP/ IAD 3. Security system IP CAM 4. Low voltage power line DC 12V / AC24V/ PoE 5. ADSL/ XDSL telecom equipment 6. PoE Module 7. HUB Switch 8. VOIP Phone 9. Other Network SHN Series Specification SFI Part No. Size Application Voltage Breakdown Voltage Surge Current Surge Voltage SFI1206SN120-060K 1206 DC 3.3V 12V 150A 6KV SFI1206SN120-040K 1206 DC 3.3V 12V 100A 4KV SFI1210SN470-060K 1210 AC 24V 47V 150A 6KV SFI1210SN470-040K 1210 AC 24V 47V 100A 4KV SFI1210SN750-060K 1210 DC 57V 75V 150A 6KV SFI1210SN750-040K 1210 DC 57V 75V 100A 4KV CSPD vs GDT Function CSPD (GDT) Size 1206, 1210 Φ5 x5.6 1206(3216) 1812(4532) BDV 12 V 75V 200V 75V Clamping Voltage <25 V >300V >500V >300V Surge (10/700μs) 6 KV 6 KV 4 KV 4 KV Respond time <1 ns > 500ns >100 ns >100 ns No Yes Yes Yes Extinguishment SHV Series UL File No. E334409- VZCA Description The general LED lighting with AC input driver will configure a MOV (Varistor) for overvoltage protection, which can provide surge protection at minimum level. However, there has been a traditional degradation problem of MOV. Not only increase costs of maintenance, but also not assemble on LED board due to height limit. Therefore, it will cause loss for production and assembly. SFI provides excellent and total solution of overvoltage protection for LED light application. We suggest to use level one or multi-level surge protection components as further protection for sensitive LED driver. Also, we recommend to use ESD protection component in LED. Application Features 1. UL Approval and meet UL requirement 2. Pass surge strike 15 times 8*20uS and keep ability of 500A 3. Pass 6KV/500A 4 times 8/20uS strikes and keep stable function 4. High voltage type up to 470V 5. Easy to design with surface mount design without lead 6. Save labor cost and easy mass production 7. Space and weight savings on PC board 8. No plastic coating guarantees better flammability rating 7 Available in tape and reel for automatic production 1. LED Lighting 2. Power Board 3. Base Station 4. AC power supply 5. Industrial equipment and controller SHV Series Specification Part Number Size Working voltage (V)) Clamping Voltage (V) Surge Current 8/20uS (1 times) Breakdown Voltage Surge Current Max Energy 8/20uS 10/100uS (15 times) capacitance AC DC V(1mA) V A A J Pf(at 1Khz) 1210SV391-201A 1210 250 320 390 647 200 100 7.2 105 1812SV471-501A 1812 275 385 470 775 500 250 13.5 200 2220SV391-501A 2220 250 320 390 647 500 250 19.8 235 2220SV431-501A 2220 275 350 430 705 500 250 21.6 215 2220SV471-801A 2220 300 385 470 775 800 500 23.7 195 2220SV391-801A 2220 250 320 390 647 800 500 31.8 320 2220SV431-801A 2220 275 350 430 705 800 500 34.7 305 2220SV471-801A 2220 300 385 470 775 800 500 38.0 290 3220SV431-501A 3220 275 350 430 705 500 250 21.0 120 3220SV391-501A 3220 250 320 390 647 500 500 20.5 125 3220SV471-501A 3220 300 385 470 775 500 250 21.6 115 3220SV431-801A 3220 275 350 430 705 800 500 65.0 490 3220SV471-801A 3220 300 385 470 775 800 500 71.2 450 SHA Series Description Surge is the voltage happen the abnormal rise or down in short time. Also in the automotive environment have more strictly request in the Load Dump ability. Our SHA series products have the world highest level load dump ability and also meet ISO7637 standard pulse 5a requirement. These series have the products for 12V and 24V systems for automotive Load Dump protection and requirement. Features Application 1. Power train System 2. Safety System 3. Comfort System 4. Driver Assistant System 5. Security System 6. Hybrid Electrical 7.Other ECU 1. Meet AEC-Q200 Rev-C requirement 2. Products can withstand ISO-7637-2 pulse 5a/5b 3. Load Dump up to 50 Joule ability highest clamping voltage function. (Ud 87V, Ri :0.5 ohm , Td: 400ms) 4. Have a good high temperature characteristic 。 (-40℃~125℃) 5. Bidirectional clamping function SHA Series Specification for 12V/24V Automotive Part Number Symbol Workin Breakdown g Voltage Voltage V(1mA) (±10%) DC Clamping Voltage Peak Current V A (for ±1 times) Load Dump Jump Start Voltage(5min) W LD(J) (for 10 times) V JUMP (V) SFI1206SA240-1R5J 12 24 <40 400 1.5 24.5 SFI1206SA240-030J 12 24 <40 400 3 24.5 SFI1206SA240-060J 12 24 <40 500 6 24.5 SFI1210SA240-030J 12 24 <40 800 3 24.5 SFI1210SA240-060J 12 24 <40 800 6 24.5 SFI1210SA240-120J 12 24 <40 1000 12 24.5 SFI1812SA240-060J 12 24 <40 1600 6 24.5 SFI1812SA240-120J 12 24 <40 1600 112 24.5 SFI1812SA240-250J 12 24 <40 2000 25 24.5 SFI2220SA240-120J 12 24 <40 3000 12 24.5 SFI2220SA240-250J 12 24 <40 3000 25 24.5 SFI2220SA240-500J 12 24 <40 5000 50 24.5 SFI3220SA240-500J 12 24 <40 5000 50 24.5 SFI3220SA240-800J 12 24 <40 5000 80 24.5 SFI2220SA470-250J 24 47 <77 3000 25 45.0 SFI2220SA470-500J 24 47 <77 4000 50 45.0 SFI3220SA470-500J 24 47 <77 5000 50 45.0 SFI3220SA470-800J 24 47 <77 5000 80 45.0 SEA Series Description CAN Bus is automotive ESD requirement. It is one of the widely used international bus and it’s smart electrical control equipment to transfer data between every electronic devices in automobile. It achieves a regional network control systems in whole vehicle and exchanges information between ECU electronic controls to become the automotive electronic control network. This series is design for this request. Features Application •Compliant with IEC61000-4-2 contact +/-30 kV •CAN Bus A, B, C • LIN •Other special requirements •Quick response time<0.5 ns •Low reverse leakage current (<0.1uA) •Operating temperature exceeds 125 ° C •Bi-directional, Bi-clamping •SMD package •Products with Lead-Free •Different capacitance values correspond to the different speed signal bus (CAN Bus) •Compatible with (ISO7637-2: 2004(E): •Pulse 1 (max. -50 V), •Pulse 2 (max. 125 V), •Pulses 3a and 3b SEA Series Specification for 12V Automotive CAN BUS Part Number Stand-off Breakdown voltage Voltage Clamping Voltage Typical capacitance ESD ability Symbol VRWM(V) V(1mA) V Typ(pf) VR=0V KV SFI0603EA240-LSP 12 22~30 <40 50 40 SFI0603EA240-MSP 12 22~30 <40 25 40 SFI0603EA240-HSP 12 22~30 <40 10 40 SEA Series Specification for 24V Automotive CAN BUS SFI0603EA240-LSP 24 22~30 <40 50 40 SFI0603EA240-MSP 24 22~30 <40 25 40 SFI0603EA240-HSP 24 22~30 <40 10 40 IP Camera Application Circuit Security control systems incorporate outdoor and indoor units. The outdoor equipment must incorporate protective components to prevent damage to the circuit and equipment by the lightning protection. It’s essential to install suitable overvoltage protection components. Here have some recommend part for the IP camera ESD and Surge solution. IP CAM ESD & Surge Solution Interface Noise Test STD. Type Recommend Part Package RJ45 Data (L-G) Surge 10/700us / 40Ω / 6KV SHN SFI1210SN750-060K 1210 RJ45 Data (L-L) Surge 10/700us / 40Ω / 2KV SHN SED323-3R30D0R4-A-11 SOD-323 RJ-45 POE Surge 10/700us / 40Ω / 6KV SHN SFI1210SN750-060K 1210 DC12V (L-G) Surge 1.2/50us / 2Ω / 4KV SHC SFI1812SC470-202A 1812 AC24V (L-G) Surge 1.2/50us / 2Ω / 4KV SHC SFI1812SC470-202A 1812 AC24V (L-L) Surge 1.2/50us / 12Ω / 2KV SHC SFI1210SC470-102A 1210 DC48V Surge 1.2/50us / 2Ω / 4KV SHC SFI1812SC470-202A 1812 Line In Surge 10/700us / 40Ω / 6KV SHN SFI1206SN120-060K 1206 Line In ESD IEC61000-4-2 / 8KV MLE SFI0402-050E101NP 0402 Alarm In Surge 10/700us / 40Ω / 6KV SHN SFI1206SN120-060K 1206 Alarm In ESD IEC61000-4-2 / 8KV MLE SFI0402-050E101NP 0402 Speaker Output Surge 1.2/50us / 42Ω / 2KV SHC SFI1206SC120-040K 1206 Speaker Output ESD IEC61000-4-2 / 8KV MLE SFI0402-050E101NP 0402 Alarm Output Surge 1.2/50us / 42Ω / 2KV SHC SFI1206SC120-040K 1206 Alarm Output ESD IEC61000-4-2 / 8KV MLE SFI0402-050E101NP 0402 RS485 Power Contact special Case MOV 14D471K 14Φ RS485 Surge 10/700us / 40Ω / 6KV GDT RS485 ESD IEC61000-4-2 / 8KV MLE SED323-150D100-B-10 SOD-323 BNC Surge 10/700us / 40Ω / 6KV GDT BNC ESD IEC61000-4-2 / 8KV MLE SFI0402-050E050PP 0402 Reset Pin ESD IEC61000-4-2 / 8KV MLE SFI0402-050E101NP 0402 SD Card ESD IEC61000-4-2 / 8KV MLE SFI0402-240E0R8PP 0402 USB ESD IEC61000-4-2 / 8KV MLE SUC0402-240E0R2PP 0402 HDMI ESD IEC61000-4-2 / 8KV MLE SUCTD1004-050S0R4P- Array IP Camera Application Circuit Security and control systems including the main front parts、transmission、control、alarm parts、 systems power supply parts, list the recommend parts as following: IP CAM interface for ESD & Surge Solution Interface Type Requirements Part No. Size Ref. Circuit RJ45 Data Surge 10x700 μs/40 Ω/6KV SHN SFI1206SN120-060K 1206 Ckt(1) RJ45 PoE Surge 10x700 μs/40 Ω/6KV SHN SFI1210SN750-060K 1210 Ckt(1) AC 24V/DC12V Surge 10x700 μs/40 Ω/6KV SHN SFI1210SN470-060K 1210 Ckt(2) SD Card ESD IEC61000-4-2/8KV MLE SFI0402-120E050PP-LF 0402 Ckt(3) USB ESD IEC61000-4-2/8KV MLE SFI0402-240E2R5PP-LF 0402 Ckt(4) Video ESD IEC61000-4-2/8KV MLE SFI0402-120E050PP-LF 0402 Ckt(2) Audio ESD IEC61000-4-2/8KV MLE SFI0402-050E330NP-LF 0402 Ckt(2) Others I/O ESD IEC61000-4-2/8KV MLE SFI0402-050E330NP-LF 0402 Ckt(2) Indoor I/O Surge IEC61000-4-5/8x20μs MLE SFI0805-120E560NP-LF 0805 Power End Station Series Lan Transformer SHN 1 CKT(1) Data Pair 2 MLE 3 1A 2A 3A 4A 5A 6A 7A 8A Data Pair 6 R R PoE(+) RJ45 Spare Pairs CKT(2) PoE(-) Power // I/O 4, 5 for 48V+ PoE(+) Spare Pairs PoE(-) CKT(3) 7, 8 for Vss The power surge protection solution depends if the ground is connected to earth. CKT(4) 1 2 3 4 Vbus D+ DUSB CLK CMD Data0 Data1 Data2 Data3 6 5 4 3 2 1 SD Card Telecom Application Circuit The traditional surge solution is to use GDT for protection, when transient voltage occurred, GDT will have a period of delay between direct current discharge and exact working. Therefore, it’s generally not only use GDTs to protect electronic equipments and add some protective components after GDT. That’s the reason why GDT has slow response and remains voltage. Due to GDT extinguish problem, original Solution GDT have to add MOV or Sidactor Original Circuit RJ45 1 2 3 4 5 6 7 8 RX2RX2+ TX1TX2- Old TX2+ TX1+ RX1- + RX1+ NEW=== Our super solution GDT Disadvantage : On application of PoE, due to the arc voltage is less than working after GDT discharge. Bcause the GDT will break and burned out and short, it becomes huge damage due to it’s extinguish problem. In order to solve the issue, it’s usually to put series of varistors or Sidactor after GDT to to prevent extinguishment. Our CSPD strong characteristic in 1. Chip Size 2. High flow ability 3. Low clamping volt 4. Quick response time and provide better solution than that. Circuit Recommend Power End Station Ethernet(RJ45) Lan Transform Lan Transformer 1 2 1 (Fig. 2) 3 Data Pair (Fig.3) 4 5 2 6 7 8 RX2RX2+ TX1TX2TX2+ TX1+ RX1RX1+ 3 1A 2A 3A 4A 5A 6A 7A 8A 1236 / 4578 Data Pair 6 R R PoE(+) RJ45 Spare Pairs PoE(-) 4, 5 for 48V+ PoE(+) Spare Pairs PoE(-) 7, 8 for Vss For 10/100 M For 1G The circuit of negative power depends if there is connected to earth. RJ 45 connector application circuit Power over Ethernet (PoE) is a technology which transfer power and data through ethernet cables. They are including telecom systems, IP phone, wireless station, IP camera, hub, computers which get power by PoE. Therefore, it must be use surge protection for Ethernet RJ45 connectors. In telecom systems are connected by Ethernet and will also have the surge or voltage problem caused by power off by the surge. The surge protective device and pass the overvoltage to earth and clamp the voltage to avoid the system damage and broken. Now the standard of 100/1000M of ethernet speed requirement and these precise devices protected is more important. Now more popular in networking application in indoor and outdoor security all need for the overvoltage and lightning protected. The interface of RJ45, the circuit is 4 wires protection (1,2/3,6). In order to have full protection for 8 wires (1, 2、3,6、4,5、7,8)and prevent the surge attacked, our CSPD products have the good characteristic and small size devices conjunction with the wires an will provide the protection. Ethernet (RJ45) surge protection Mode Test Standard Series L-G 10x700μs/40 ohm /6KV SHN L-G 10x700 μs/40 ohm/4KV SHN L-L 10x700 μs/40 ohm/4KV L-L Package Cap. SFI1206SN120-060K 1206 -- SFI1206SN120-040K 1206 --- TVS(A) SEDSO8-2R8S050-A-11 SO8 5 pF 10x700 μs/40 ohm/2KV TVS (B) SEDSO8-2R8S050-B-11 SO8 5 pF L-L 10x700 μs/40 ohm/2KV TVS(F) SEDSO8-2R8S020-F-11 SO8 2pF L-L 10x700 μs/40 ohm/2KV TVS SED1006-3R30D7R0-D-11 0402 7pF L-L 10x700 μs/40 ohm/2KV TVS SED323-3R30R0R4-A-11-LF SOD323 0.4pF Part No. Application Part No. Surge (10x700 μs) SFI1206SN120-060K Networking(Ethernet) Data 6KV SFI1206SN120-040K Networking(Ethernet) Data 4KV SFI1210SN470-060K Power Line 6KV SFI1210SN470-040K Power Line 4KV SFI1210SN750-060K PoE 6KV SFI1210SN750-040K PoE 4KV RJ45 Application Circuit Ethernet (RJ45) Surge Protection Test Mode Test Standard Series L-G 10x700 μs/40 ohm /6KV SHN L-G 10x700 μs/40 ohm/4KV SHN L-L 10x700 μs/40 ohm/4KV L-L Part No. Package Speed SFI1206SN120-060K 1206 Both SFI1206SN120-040K 1206 Both TVS(A) SEDSO8-2R8S050-A-11 SO8 10/100 10x700 μs/40 ohm/2KV TVS (B) SEDSO8-2R8S050-B-11 SO8 10/100 L-L 10x700 μs/40 ohm/2KV TVS(F) SEDSO8-2R8S020-F-11 SO8 1G L-L 10x700 μs/40 ohm/2KV TVS SED1006-3R30D7R0-D-11 0402 1G Lan Transformer Tx+ 1 SHN 2 TVS Tx- Rx+ 3 RJ45 1A 2A 3A 4A 5A 6A 7A 8A 6 Rx- Tx+ TVS Package 4 5 Tx- Rx+ 7 8 R R R Rx- Type A /F So8 Single X 4 pcs R SO8 X 1 pcs Type B SO8 Line to Line Line to Ground TVS Parameter VRWM (max) VB (min) IT (5A max) VC (5A) VC (24A) IR (uA) CT (pF) Package SEDSO8-2R8S050-A-11-LF 2.8 3 1 8.5 15 5 5 SO8 SEDSO8-2R8S050-B-11-LF 2.8 3 1 8.5 15 5 5 SO8 SEDSO8-2R8S020-F-11-LF 2.8 3 1 8.5 15 5 2 SO8 Reference Application Circuit SFI Automotive Load Dump Solution SFI USB ESD Solution SFI DC Power Solution SFI Auto CAN BUS ESD Solution R1 SMD type for AC power over voltage protection R2 BD Fuse Driver IC Surge Protection SMD package to replace Dip type LED Matrix DC to DC Converter Surge Protection device with DC Low voltage Surge Protection SHV Type SHV SHC MLE device with AC High voltage Part Number SHC Working Voltage Breakdown Voltage ESD Protection device with DC Lower voltage MLE Clamping Voltage Surge Current Surge Current (8/20 μs/1 time) (8/20 μs/ (15 times) Symbol AC DC V(1mA) V A A SFI1210SV391-201A 250 320 390(±10%) 647 200 100 SFI2220SV391-801A 250 320 390(±10%) 647 800 500 SFI2220SV431-801A 275 350 430(±10%) 705 800 500 SFI2220SV471-801A 300 385 470(±10%) 775 800 500 SFI3220SV431-801A 275 350 430(±10%) 705 800 500 SFI3220SV471-801A 300 385 470(±10%) 775 800 500 SFI1206SC240-501A 14 18 24(±10%) 45 500 ND SFI1210SC240-102A 14 18 24(±10%) 45 1000 ND SFI0603-050E220NP 3.3 5 15~25 34 ND ND SFI0603-120E100NP 8 12 27~42 60 ND ND SFI Electronics Technology Inc. Category B Category C Category A Service drop Service entrance Transformer ● ● ● ● Outlet Utility pole Meter Disconnect breaker Outlet 30 ft 60 ft Category C: Service entrance, more severe environment: 10kV, 10kA surge. Category B: Downstream, 30 ft from category C, less severe environment: 6kV, 3kA surge. Category A: Further downstream, 60 ft from category C, least severe environment: 6kV, 0.5kA surge. Category Voltage Current Impedance 1.2/50 μs 8/20 μs ohm C(Outdoor) 6KV 3KA 2 Outdoor Commercial , Industrial / Parking B 6KV 3KA 2 Lighting near Service Entrance A(Indoor) 6KV 0.5KA 12 Indoor /Offices/ Retail United States Application Europe / America Taiwan China Surge Immunity 1.2*50 μs/ 8*20 μs LED light bulbs inside IEEE62.41.2 Ring wave 2.5KV 100Khz Class A IEC/EN61547 (IEC61000-4-5) 500V/250A,1KV/500A CNS14676-5 (IEC/EN61000-45) 500V/250A 1KV/500A GB/T18595 (IEC/EN61547) 500V/250A 1KV/500A Surge Immunity 1.2*50 μs/ 8*20 μs LED outdoor Luminaires IEEE62.41.2(Category C) 6KV/3KA 20KV/10KA IEC/EN61547 IEC/EN61000-4-5 4KV/2KA, 6KV/3KA,10KV/5KA IEC/EN61000-4-5 4KV/2KA IEC/EN61000-4-5 4KV/2KA Safety UL8750, UL1310 UL1993, UL1598 IEC/EN62560,IEC/EN60598 IEC/EN61347,IEC/EN62031 CNS STD. GB24819-2009 IEC62031 Character Test Level Device Self-ballasted Lamp & Semi-luminaries Luminaries & independent auxiliaries < =25W > 25W Surge waveform 1.2*50µs 1.2*50µs 1.2*50µs Line to Line 1.0KV 1.0KV 1.0KV Line to Ground 1.0KV 1.0KV 2.0KV SFI Electronics Technology Inc. TEL : +886-3-3506998 , Fax: +886-3- SFI Service Feedback Immediately Taiwan Headquarter: Address: No.6, Lane 340, Shan Ying Road Guishan Taoyuan 333 Taiwan TEL :+886-3-3506998 FAX: +886-3-3507689 E-mail:[email protected] [email protected] Shenzhen China : Address: Room 208, Building 212, Tairan Industry Park Futain District, Shenzhen China TEL:+86-18676730214 TEL:+86-755-83589593 FAX: +86-755-83589574 E-mail:[email protected] ShangHai China: Address: Room 601, No.11 of 111 Sub-Lane South City, Lane 7580, Humin Road, Shanghai China TEL:+86-18601216474 TEL:+86-21-62775426 FAX: +86-21-62776349 E-mail:[email protected]