The Powerstar inverter range is designed to be a robust
& reliable hybrid energy storage platform. It is ideal for
applications as varied as off-grid farms and lodges
to urban houses and factories. It provides a smart &
seamless interface between the grid, generators,
renewable energy and storage.
The Powerstar is unique in the storage inverter market
for its ability to clean incoming power & regulate the
output voltage.
a De signed for ha rsh environment s
a 6 to 24 kVA units, able to parallel up to 96kVA
a 1 and 3-phase transformer-based
a Low-voltage DC (36 & 48 V)
Features
Voltage & Power Quality Regulation
The Powerstar inverter “cleans” the incoming grid/generator voltage of any distortion to ensure that the
output voltage is a pure 230V sine wave.
Automatic Generator Start
In off-grid systems, the Powerstar will automatically start the generator when the battery voltage
is low. The inverter synchronises with the generator and connects seamlessly. When the charge
cycle is complete the inverter will turn off the generator and transition back to stand-alone mode
with no power interruption to the load.
Source Monitoring
The Powerstar will monitor the available power sources (e.g. grid, generator, solar PV, or
wind) and the rate at which they charge your batteries. The inverter dynamically adjusts
the rate of charge to ensure that the batteries are protected and are never overcharged.
Export Power Control
The Powerstar has advanced export power control that prevents power from flowing back
into the grid and tripping pre-paid meters.
SmartLoad Load Prioritization
The Powerstar features SmartLoad, a programmable three priority level load-shedding system. The inverter
will automatically connect/disconnect user-defined loads based on the current state of charge of your
batteries. For example, SmartLoad can allow non-critical loads such as air-con systems to run when the
batteries are full and grid power is available but to shed these loads when running off batteries so that
critical loads such as fridges & lights can be powered for longer.
31-10-2014
Specifications
S Y S T E M R AT I N G S
Powerstar 6/8
Powerstar 12/16
Powerstar 18/24
Rated Voltage/Frequency
1ø, 230 V / 50 Hz, 277V /
60Hz (8kVA only)
1ø, 230 V / 50 Hz, 277V /
60Hz (16kVA only)
1ø or 3ø, 230 V or 400V /
50 Hz, 277V or 480V / 60
Hz (24kVA only)
Input Voltage Range
+/- 19% of nominal V
+/- 19% of nominal V
+/- 19% of nominal V
Input Frequency Range
Rated Output Power
Maximum Output Current per phase
THD I (at rated power)
Protection
48..58 Hz
6 / 8 kVA
48..58 Hz
48..58 Hz
12 /16 kVA
18 / 24 kVA
40 / 52 A (for 30s), 52 / 70 A (for 5s)
< 3%
Overload, Overcurrent, Short Circuit, Over Temperature, Under/Over Voltage, Under/Over Frequency
B AT T E RY I N P U T
Nominal Battery Voltage
Maximum Battery Charge Current (Adj.)
Recommended Minimum Battery Size
Battery Technology
48 V (36 kVA / 6 kVA on request)
100 / 150 A
200 Ah
48 V
200 / 300 A
350 Ah
Lead Acid / Vanadium Redox
48 V
300 / 450 A
500 Ah
E F F I C E N CY
Effeciency (peak)
Tare Losses in Standby (Night)
Standby Losses (Load Sensing)
< 40W / 50 W
Up to 92% stand-alone, Up to 95% with source connected
< 70W / 90 W
< 105 W / 140 W
<8W
C O N N EC TO R S
DC Input
AC
50 mm² Cable Included
10/16 mm² Terminal Blocks
50 mm² Cable Included
10/16 mm² Terminal Blocks
50 mm² Cable Included
10/16 mm² Terminal Blocks
G E N E R A L S P EC I F I C AT I O N S
Mounting Method
Dimensions (W x H x D)
Weight
IP/NEMA Rating
Colour
Cooling Method
Floor Standing
550 x 930 x 510 mm
170 / 190 kg
IP30 / NEMA1
RAL7032
Forced Air
550 x 550 x 510 mm
85 / 95 kg
550 x 1200 x 510 mm
250 / 280 kg
C L I M AT I C C O N D I T I O N S
Ambient Temperature
Ambient Transport Temperature
Maximum Ambient for Rated Power
Relative Humidity
Maximum Altitude for Rated Power
-5..45 °C
-25..70 °C
40 °C
5..85 %
1000 m above sea level (Power derated for Higher Altitudes)
O P E R ATO R PA N E L
Display Type
Communications
40 x 4 Blue LCD with membrane keypad
RS232 MODBUS RTU Slave (Ethernet Optional)
Accessories:
External Temperature Sensors
Dual DC Monitoring inputs
These temperature sensors allow for fine
control over battery charging.
Multiple DC input ports allows the inverter to
monitor and dynamically adjust the battery
charge current based on renewable input
power.
Remote Monitoring and
Control
Load shedding contactors
Off-site, web connected supervisory control
and data acquisition with historical and realtime
views.
Loads will be disable based on priority and
various criteria, for example battery voltage
and current load.
Bypass box
Grid Loss Siren
Allows bypass of the inverter for easy
maintenance.
Audible buzzer to warn that grid has fallen
away and that batteries are being used.