GB.XZONE.120522 Function Guide for the GOLD, Xzone 1. General 2. Material Specification The Xzone function is designed for controlling one extra temperature zone via the ventilation system. Sometimes it is necessary to control a part of the ventilation system with different temperature prerequisites. This may be due to proximity to the perimeter wall of the building facing north or south; workshop, office or other conditions that give rise to different temperature loads in various parts of a building. The Xzone function can control one extra temperature zone, max. Xzone can be used for all types of GOLD air handling unit with program version 5.00 or later, and both postheating and cooling can be controlled in the extra zone. When Xzone is activated, several menus appear in the hand-held micro terminal under user level for setting and reading the extra zone parameters. The type of temperature control for the extra zone must be selected separately, and can be of another type than that used in the main zone. If extract air temperature control is selected, the temperature sensors must be positioned so that they will not be influenced by the temperature in the other zone. This means that the internal extract air sensor (inside the air handling unit) must not be used for control for the main zone. The room sensor or extra extract air sensor should be used, (see TBLZ-1-30 or TBLZ-1-24 in section Material Specification). The air heater and air cooler for the main and extra zone must be sized on the basis of separate computerized calculations. Always take into account that the duct system where the air heater and air cooler are fitted, does not have the same dimensions as the connection spigots/ frames of the air handling unit. We reserve the right to alter specifications. Air handling unit: GOLD RX/PX/CX/SD Xzone Control box TBLZ-1-50-a-b-cc Consists of:IQnomic Plus, TBIQ-2-1, heating IQnomic Plus, TBIQ-2-1, cooling Comm. cable BC1-1 (L=250mm) Code:a 0 = Without freeze protection monitor sensor 1 = With freeze protection monitor sensor b 1= With supply air temperature sensor 2 = With supply air and extract air temperature sensor 3 = With supply air and room air temperature sensor cc 01 = With 1 metre long communication cable 03 = With 3 metre long communication cable 05 = With 5 metre long communication cable 10 = With 10 metre long communication cable 15 = With 15 metre long communication cable Supply air temperature sensor, set (TBLZ-1-30), according to selection above consists of the following: Duct temperature sensor 32106304 Jack for wall mounting 019611 Extract air temperature sensor, set (TBLZ-1-30), according to selection above consists of the following: Duct temperature sensor 32106304 Jack for wall mounting 019611 Room temperature sensor (TBLZ-1-24), according to selection above. When the heater is electric of type Swegon standard incl. control cable: Adaptor modular/terminal TBLZ-1-55 www.swegon.com 1 GB.XZONE.120522 3. Operation The Xzone function requires två IQnomic Plus modules for wiring temperature sensors as well as an air heater for postheating and an air cooler. The wiring of temperature sensors to the IQnomic Plus requires the presence of both modules in the system even if there is only one air heater or one air cooler in the zone. Connect a cable for 0-10 V DC control of valve actuator - heating and cables for control of the pump for the reheater (if any), supply air temperature and freeze protection monitor sensors to the IQnomic Plus module A (function selector switch = A). If an electric air heater is used, connect the overheating protection alarm signal cable to the input of the freeze protection monitor sensor. Connect a cable for 0-10 V DC control of the valve actuator cooling or air cooler for cooling in 1 - 3 steps or cooling pump control and extract air/room air sensors to the IQnomic Plus module B (function selector switch = B). The Xzone for heating and Xzone for cooling must each be activated separately. The type of control signal for the heating and cooling function respectively must be selected individually. Temperature control for the Xzone operates completely separated from the temperature control of the main zone. If an air heater for postheating with freeze protection monitor is selected for the extra zone, the heat retaining function operates completely separately. The heat retaining and alarm limit values preset at service level are applicable to both the extra zone and the main zone. 2 www.swegon.com The cooling min. flow function applies to the flow from the air handling unit, not the flow for each zone. When the total flow reaches below the preset value, cooling will be blocked in both zones. If intermittent night-time operation is activated, the conditions in the main zone are controlled according to the settings of the function. When the air handling uit starts up, the extra zone is controlled according to ordinary temperature control settings. Connect the cable of the air heater for main zone postheating to the ordinary heating output on the GOLD air handling unit control unit. Connect the main zone’s cooling control cables to the ordinary cooling outputs on the GOLD air handling unit control unit. Connect the air heater of the extra zone to the screw connection terminals of the IQnomic Plus module. The heating output cannot have modular connection and if standard coils for GOLD with modular connection are used for the extra zone, the cable will have to be cut. Important! The function with output power reduction (for an electric air heater), activated in the event of low airflows for protecting the heater elements from overheating, is blocked when the Xzone is selected. Since the control system cannot measure the flow in the different zones, the function is blocked both for the extra zone and the main zone. We reserve the right to alter specifications. GB.XZONE.120522 4. Electrical connections Jack for wall mounting, 019611 IQnomic Plus module Valve actuator, cooling or air cooler 0-10 V Air heater for hot water 1) Temp. sensor** supply air Temp. sensor** extract air/room 1) Jack for wall mounting, 019611 Freeze protection monitor sensor** R1 RD T1 GR R1 RD T1 GR Data GND Valve actuator, heating G G0 Y 24 V AC* IQnomic Plus module A 24 V AC* – S Brown White G G0 Y – S – S – S – S 13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 F 012 L1 L2 BCDE 1 2 3 4 5 6 7 8 9 10 11 12 Control of pump for heating Control of cooling step 1 or pump in cooling circuit IQnomic Plus module B Function selector switch in position B 34 5 6 7 89A 7 89A F 012 34 5 6 BCDE Function selector switch in position A Communication cable to the control unit of the air handling unit, where it must be connected to one of the connections for Internal EIA-485. Room sensor * The 24 V AC powersupply conductors can 1 2 3 4 5 6 7 8 9 10 11 12 be connected to Terminals 60 (G) and 61 (G0) in the control unit of the air handling unit. ** Digital temperature sensors require correct polarity. Be careful Communication cable when you wire the between modules. conductors. L1 L2 Control of cooling step 2 1 2 3 4 5 6 7 Pump controls Supply voltage to 1-phase pump, max 1.5 A, can be obtained by wiring to the following terminals inside the GOLD air handling unit: Terminal 101 (L), terminal 102 (N). PE N L We reserve the right to alter specifications. www.swegon.com 3 GB.XZONE.120522 Electric air heater Swegon Standard with control cable Jack for wall mounting, 8-pole BL OR BK RD Temp. sensor,** supply air WH BR YL GR Overheating protection 0-10 V – S – S 13 14 15 16 17 18 19 20 21 22 23 24 F 012 L1 L2 L1 L2 1 2 3 4 5 6 7 8 9 10 11 12 BCDE Control of cooling step 2 www.swegon.com Function selector switch in Position B 34 5 6 Control of cooling step 1 or pump in cooling circuit 4 IQnomic Plus Module B 7 89A 7 89A F 012 34 5 6 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 Room sensor 24 VAC* – S – S Function selector switch in Position A T1 GR G G0 Y 13 14 15 16 17 18 19 20 21 22 23 24 PE N L R1 RD GR Data GND IQnomic Plus Module A Communication cable to the control unit of the air handling unit, where it should be connected to one of the connections for Internal EIA-485. Jack för väggmontage, 019611 Valve actuator, cooling or cooT1 ling 0–10 V R1 RD 24 VAC*** G0 Temp. sensor,** extract air BCDE Electric air heater Swegon Standard with control cable, 0–10 V, pause/pulse Jack for wall mounting, 019611 Pump controls Supply voltage to 1-phase pump, max 1.5 A, can be obtained by wiring to the following terminals inside the GOLD air handling unit: Terminal 101 (L), terminal 102 (N). Communication cable between modules. * The 24 V AC power-supply conductors can be connected to Terminals 60 (G) and 61 (G0) in the control unit of the air handling unit. ** Digital temperature sensors require correct polarity. Be careful when you wire the conductors. *** Electrical air heater above 36 kW 440 V and above 27 kW 230 V (Norway) demand supply voltage 24 VAC to internal control equipment. Supply voltage 24 VAC can be connected on the AHU control unit, terminal block 60 (G) and 61 (G0). We reserve the right to alter specifications. GB.XZONE.120522 5. Adjustment. For basic particulars on how to handle the hand-held micro terminal, see the Operation and Maintenance Instructions for the GOLD unit. INSTALLATION FUNCTIONS *FUNCTIONS* TEMPERATURE FLOW/PRESSURE FILTER The Xzone function must be manually activated, under INSTALLATION – FUNCTIONS – IQNOMIC PLUS in the hand-held terminal. OPERATION HEATING COOLING MOISTURE ReCO2 IQNOMIC PLUS If postheating is required in the extra zone, activate No. A XZONE HEATING by selecting what type of air heater is to be connected, under FUNCTION ON/OFF. *IQNOMIC PLUS* NO. 9 PREHEATING NO. A XZONE HEATING NO. B XZONE COOLING *XZONE HEATING* FUNCTION OFF/ON DEACTIVATE EL AIR HEATER, P/P EL AIR HEATER, 0 - 10 V WATER COIL WITH FP WATER C. WITHOUT FP If cooling is required in the extra zone, activate No. B XZONE HEATING by selecting control function under FUNCTION ON/OFF. *IQNOMIC PLUS* NO. 9 PREHEATING NO. A XZONE HEATING NO. B XZONE COOLING *XZONE COOLING* FUNCTION OFF/ON SETTINGS DEACTIVATE STEPLESS 0 = 10 V STEPLESS 10 = 0 V ON/OFF, 1 STEP ON/OFF, 2 STEPS ON/OFF, 3 STEPS BINARY The neutral zone required between the heating and cooling sequences must be set under SETTINGS. We reserve the right to alter specifications. *XZONE COOLING* NEUTRAL ZONE 2.0°C. www.swegon.com 5 GB.XZONE.120522 When one of the functions XZONE HEATING or XZONE COOLING is activated, a new menu image is displayed in the hand-held micro terminal: TEMP.CTRL.XZONE, under INSTALLATION – FUNCTIONS - TEMPERATURE”. *TEMPERATURE* TEMPERATURE CTRL TEMP.CTRL. Xzone OUTD TEMP COMP. The extra zone has the same settings as the ordinary menu of the air handling unit for the setting temperature control modes. *TEMP.CTRL.XZONE* ERS CONTROL 1 OTHERS? ERS CONTROL SUPPLY AIR CONTROL EXTRACT AIR CONTROL A new menu group XZONE is displayed between TEMPERATURE and FLOW/PRESSURE under SETTINGS at user level. The selected temperature control function setpoint settings required for for the extra zone can be set there. XZONE *XZONE* READINGS SETTING 6 www.swegon.com We reserve the right to alter specifications. GB.XZONE.120522 Performance checks F 012 A flashing light-emitting diode L1 indicates correct communication with the GOLD unit’s control unit. 13 14 15 16 17 18 19 20 21 22 23 24 34 5 6 7 89A IQnomic Plus module: Light-emitting diode L2 lit with a steady glow indicates that power is being supplied from the GOLD unit’s control unit. BCDE 6. L1 L2 1 2 3 4 5 6 7 8 9 10 11 12 L1 L2 Temperature sensor: Current temperatures can be read under INSTALLATION – READINGS – IQNOMIC PLUS – XZONE HEATING/XZONE COOLING. If the temperature readings are resonable, wiring has been carried out correctly. If the functions are activated but the accessories have not been connected correctly, an alarm will be initiated. See the Operation and Maintenance Instructions for the GOLD unit for a description of each alarm. We reserve the right to alter specifications. www.swegon.com 7