EWHS 300/310 Humidity Sensors Technical Data Sheet GENERAL DESCRIPTION The humidity sensors of the EWHS 300/310 series are designed to be connected to high-accuracy humidity and humidity/temperature measuring devices. The EWHS 300 is a humidity measuring device (output signal 4...20 mA) while the EWHS 310 is a humidity and temperature measuring device (two 0...20 mA outputs). INSTALLATION do not cause any mechanical stress to the sensors and absolutely avoid touching the humidity sensor. Use a suitable cable gland to make the cable exit and connect it to the terminals according to the instructions shown on the label located on the inner side of the cover and on the printed circuit. Humidity and/or temperature reading errors can occur if settling time is too short, or be caused by steam, sprayed water, air drafts, direct exposure to sunlight, presence of condensate on the sensor, or by mounting the device on a wall cooled by the outside temperature; the sensor should be installed in such a way that it is protected against any possible external factors. To obtain highly accurate measurements, the sensor should be left to settle in the existing atmosphere for some time. Since the sensor has a mass which affects the measurement, such "settling time" should be allowed especially when the sensor is exposed to a temperature jump. Condensate may form on the humidity sensor when there is a quick variation of temperature and the atmosphere goes from a low temperature value (cold sensor) to a high one. CONNECTION DIAGRAMS EWHS 300 There are two slots on the outer side of the enclosure to mount the device on the wall by using suitable screws and anchors. To access the terminal block, remove the cover by unscrewing the two screws on it. Avoid touching any electronic components. Should it be necessary to remove the protective cap, KEY A B Humidity Supply voltage EWHS 310 KEY A B C D Temperature T Humidity RH Ground GND Supply voltage V+ CONDITIONS OF USE INTENDED USE For safety reasons, the control device shall be installed and used in accordance with the instructions supplied. The device must be protected from water and dust according to the application. DISALLOWED USE Any use different from the intended one is prohibited. We point out that this sensor provides only a functional measurement, cannot be considered as a safety device, and is subject to failure. Any protection devices required by the regulations applicable to the product or suggested by common sense due to obvious safety requirements must therefore be carried out in a different way. RESPONSABILITY AND RESIDUAL RISKS TECHNICAL DATA Invensys Controls Italy s.r.l. is not liable for any damage due to: - installation/use other than specified and, in particular, differing from the safety specifications of the legal regulations and/or supplied with the present handbook; - protection against electrical shocks, water and dust under the effected installation conditions; -use on electrical panels permitting access to dangerous parts without use of tools. -tampering with and/or alteration of the product; -installation/use in panels not conforming to standards and regulations of current laws. Protection rating: IP65 Mounting: through two external slots Electrical connections: screw terminals Dimensions (mm): 80X80X52 Power supply: 9…30 Vc Power input: • EWHS 300: 20mA max • EWHS 310: 50mA max. Ambient temperature: -30° (-22°F) to +70°C (158°F) Ambient humidity: 0…100% RH Humidity sensor: capacitive Temperature sensor (EWHS 310 only): Pt100B Temperature measurement range (EWHS 310 only): -30° (-22°F) to +70°C (158°F) Humidity measurement range: 0…100% RH Output current of humidity measurement • EWHS 300: 4 (0%)…20mA (100%) • EWHS 310: 0 (0%)…20mA (100%) Output current of temperature measurement EWHS 310: 0 (-30°C)…20mA (+70°C) Response time under constant conditions (63%) at 23°C (73.4°F): 30 seconds Saturation recovery time: 90 seconds Storage temperature: -30°C (°F) to +80°C (176°F) Number of connection wires: • EWHS 300: 2 • EWHS 310: 4 CHEMICAL RESISTANCE The values shown in the table below are given only for guidance purposes. The chemical resistance of the sensor is highly affected by the prevailing humidity and temperature conditions and by the length of exposure time to the pollutant. Exposure to higher concentrations is possible provided that exposure time is shorter and that the sensor can then recover in a "clean" environment or in a flow of gas (purging). Permissible error due to exposure to a pollutant is ± 2 % RH Pollutant Table Maximum load: 250 Ohm Humidity measurement accuracy (at 23°C/73.4°F): EWHS 300: ±2% RH (10..95% RH) ±3% RH (<10% >95% RH) EWHS 310: ±1.5% RH (10..95% RH) ±2% RH (<10% >95% RH) Temperature measurement accuracy at 0°C (32°F) and 23°C (73.4°F) (EWHS 310 only): 0.5°C (for different temperature values, accuracy is that of Pt100B plus 0.2°C) Air filter: polyethylene Reverse polarity protection: by diode Temperature compensation: • EWHS 300: with NTC • EWHS 310: with Pt100B Max. air speed: 20m/s DISCLAIMER This manual and its contents remain the sole property Invensys Controls Italy s.r.l. and shall not be reproduced or distributed without authorization. Although great care has been exercised in the preparation of this document, Invensys Controls Italy s.r.l., its employees or its vendors, cannot accept any liability whatsoever connected with its use. Invensys Controls Italy s.r.l. reserves the right to make any changes or improvements without prior notice. The valu es sh own i n the table be lo w (Pollu ta nt Table) Pollutant Chemical Formula Maximum Workplace Concentration ppm Acetone Ammonia Petrol Chlorine Acetic acid Ethyl acetate Ethanol Ethylene glycol Ethylene oxide Formaldehyde Isopropanol 2-Butanone (MEK) Hydrochloric acid Sulphur dioxide Hydrogen sulphide Nitrogen oxides Toluene / Xylene CH3COCH3 NH3 Cl2 CH3COOH CH3COOC2H5 C2H5OH HOCH2CH2OH C2H4O HCHO (CH3)2CHOH C2H5COCH3 HCl SO2 H2S NOx C6H5CH3 1000 25 300 1 10 400 1000 100 3 1 400 200 5 5 10 5 100 mg/m3 2400 18 1200 1.5 25 1400 1900 260 1.2 980 590 7 13 15 9 380 C94 Permissible Concentration for Continuous Operation ppm mg/m3 3300 5500 800 4000 3500 1200 0 2400 4800 3300 300 5 350 5 1300 8000 4000 150000 2 2000 15000 6000 3000 0 3000 12000 8000 500 13 500 9 5000 EWHS 300/310 2000/12 300/310 Cod:EWHS 9IS22006 2/2