Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
1.2 Controls/Networks 2016.3 MULTiBUS-Coupler MULTiBUS®-Coupler MULTiBUS-Coupler Controls/Networks 2016.3 1.2 Extend (third-party) lift controls with LIFTnet, a dynamic fire control and a lift attendant. MULTiBUS Coupler ® MULTiBUS-Coupler is an industry-oriented Linux module by STRACK specifically for lifts and technical installations and works as a data collector, mini control and gateway. The connection with almost all (foreign) manufacturers of control is through unlimited, TÜV approved „intelligent“ universal voltage in-/outputs. MULTiBUS Coupler couples all lift controllers to LIFTnet, complements it (regardless of LIFTnet) with an electronic lift attendant and extends it with a static and dynamic fire alarm control. WLAN www.strack-lift-automation.de 11 1.2 Controls/Networks 2016.3 MULTiBUS-Coupler At a glance: n LINUX machine specifically for lifts and an industrial environment n extends almost any (third-party) lift control n snapable onto DIN rail, only little space required n modules connected with LINK bus to each other, flexible positioning n industrial standard interfaces n high-performance and low power n TÜV-certified, can be directly connected to the safety circuit n any voltage 8 - 250V in controls is pick-ups and switchable n static and dynamic fire alarm control n electronic lift attendant n integrates (third-party) controls into LIFTnet Controls/Networks 2016.3 MULTiBUS-Coupler Product description 1.2 Das MULTiBUS-System Interfaces VIO virtual in-/outputs MULTiBUS is a modular system which under- MULTiBUS has Ethernet and USB interfaces, MULTiBUS-Coupler works by default with It can expand existing (third-party) lift control tems and transmission media, such as e.g. Wi- (VIO). You can assign a VIO of any terminal of takes many tasks in lifts or other equipment. systems with control functions, data collecting, or work as a gateway. The MULTiBUS interface in conjunction with LINUX as operating system represent an important innovation for elevator technology. LINUX is successfully in use due to its stability in the industry for a long time and there are many tools that are freely available. Power and consumption The MULTiBUS heart beats in the coupler: a po- werful ARM processor with extremely low po- wer consumption. Also, there are no heat sink and no power guzzler in the entire MULTiBUS module system! LINK bus All MULTiBUS modules are connected with each other with the 2-wire bus LINK, so that the signals of the system can be used regardless of the position. The royalty free LINK bus has a high operating safety and unusually good diagnostic ability. For example, if a bus stop, a short circuit or engine defect occurs, the MULTiBUS-Coupler logs, where the error has just occurred. with which connections in networks, bus sys- Fi, Bluetooth, CAN, LON, LAN and WAN (Internet) are possible. Also the communication via real-time Ethernet protocols, such as Modbus TCP is provided. To connect to the Internet, various protection mechanisms are included, such as firewall, IP check, password protection, and write protec- thousands of so-called „virtual in-/outputs“ any MULTiBUS module. Thus, the function of this VIO number is assigned to the real terminal so that the terminal has then the function „re- turn on/off“, for example. So the wiring is low, no additional relay is required, possible contact faults and space requirements are minimal. ted boot areas. VIO virtual in-/outputs with software mapping by menu + (NO) - (NC) 00000 number MULTiBUS module single terminal inspection return control VIO number +00060 i.e. inspection on when contact is closed VIO number -00064 i.e. return control on when contact is open MULTiBUS module www.strack-lift-automation.de 13 1.2 Controls/Networks 2016.3 MULTiBUS-Coupler MULTiBUS extension modules (selection) IOM-Switch t IOM-Switch provides 5 Ethernet interfaces with 10/100 MBit/s. In general, the module works as dr af intelligent „unmanaged“ switch plug and play, however, including automatic control functions like „broadcast storming filter“ and „bandwidth, ingress and egress rate control“ of each port. With ad- ditional configuration via the LINK bus, the switch can be changed to a ‚managed‘ switch, e.g. to channel up to 16 VLANs (virtual LANs), to set priorities for Ethernet devices, etc. IOM-16 IOM-16 provides 16 not potential-free in-/outputs for 24V DC. Each terminal can be configured as input, output, or both, and is able to switch an inductive load up to 350 mA. Each terminal is protected against overtemperature, overvoltage, reverse voltage and high current, equipped with comprehensive diagnostic functions and qualified to AEC-Q100 (reliability acc. to Automotive Electronics Council). IOM-SHKIN IOM-SHKIN provides 8 inputs for 230V AC. The 2 input groups (6+2 inputs) are to each other po- tential-separated and may be connected to different circuits, also to the safety circuit. In addition, neighboring input circuits are allowed to have dangerous and non-dangerous voltages. High open-circuit voltages which occur due to parasitic coupling in long open lines (e.g. open safety circuit contacts), do not lead to incorrect results! IOM-UIN IOM-UIN provides 12 universal voltage inputs for 8-250V AC/DC. The 6 input groups (3+3+2+2+1+1 inputs) are to each other potential-separated and may be connected to different circuits, also to the safety circuit. In addition, neighboring input circuits are allowed to have dangerous and nondangerous voltages. High open-circuit voltages which occur due to parasitic coupling in long open lines (e.g. open safety circuit contacts), do not lead to incorrect results because the IOM-UIN always knows what voltage level and type at each input can be expected! 14 www.strack-lift-automation.de MULTiBUS-Coupler Controls/Networks 2016.3 1.2 IOM-R6 IOM-R6 is a module with 6 relays changers with a maximum switching capacity of 250V/6A/AC1 or 192W/250V/5A/DC1. The 5 groups (1+1+1+1+2 outputs) are to each other potential-separated and may be connected to different circuits, also to the safety circuit. In addition, neighboring output circuits are allowed to have dangerous and non-dangerous voltages. IOM-Audio IOM-Audio is a robust MP3 stereo module, which can play high quality language, music and acoustic signals. One or two speaker for mono or stereo can be connected. The integrated digital amplifier has a very high degree of efficiency, requires no cooling and provides 2x30W into 4 Ohm or 2x15W into 8 Ohm speaker. The speaker outputs are short-circuit-proof. The IOM-Audio plays MP3 music files and fades-in voice prompts in 1-4 languages. Volume, pitch, and other parameters are configurable by MULTiBUS or LIFTnet. New or modified MP3 files can be uploaded live or modified separately on the 2GB SD card. www.strack-lift-automation.de 15 1.2 Controls/Networks 2016.3 MULTiBUS-Coupler MULTiBUS-Coupler as fire alarm control MULTiBUS-Coupler can extend a lift control control provides the needed in-/outputs (e.g. other functions of the lift control. Each lift control is extensible, if the required only control signals that all controllers know, made after the fire alarm evacuation by the with a static and dynamic fire alarm control. inputs and outputs are accessible. A bus based lift control is expanded in the same way, if the with an own bus module). The coupler uses e.g. floor information, calls and car priority switch. There will be no interference with the Optionally, a fire alarm announcement can be IOM-Audio. Dynamic fire alarm control for a lift control, which works with 24V positive logic, up to about 3 floors E.g. compatible to Böhnke bpXXX, Kollmorgen MPK 50X/100X/200X and STRACK STA90/STA². The terminal assignment can be changed freely. If you disable door light barrier IOM-R6 IOM-16 (reserve) call 1 call 2 call 3 (reserve) Coupler + keep door closed (simulate open) + - priority travel 0V lift control shut down lift +24V lift control disable car panel general fire alarm smoke detector 1 smoke detector 2 smoke detector 3 inspection lift travelling up lift travelling down door is open flush floor level 1 floor level 2 floor level 3 need fewer inputs for smoke detectors or floor information, the lift also may have up to 7 levels without the need of additional modules. Same as above, but up to about 8 levels 16 IOM-16 disable door light barrier priority travel IOM-R6 (reserve) + keep door closed (simulate open) IOM-16 call 1 call 2 call 3 call 4 Coupler + call 5 call 6 call 7 call 8 (reserve) + - disable car panel 0V lift control shut down lift +24V lift control door is open flush floor level 1 floor level 2 floor level 3 floor level 4 floor level 5 floor level 6 floor level 7 floor level 8 (reserve) general fire alarm smoke detector 1 smoke detector 2 smoke detector 3 smoke detector 4 smoke detector 5 smoke detector 6 smoke detector 7 smoke detector 8 inspection lift travelling up lift travelling down If you need fewer inputs for smoke detectors or floor information, the lift also may have up to 21 levels without the need of additional modules. www.strack-lift-automation.de 90-264VAC www.strack-lift-automation.de (reserve) (reserve) (reserve) call 6 call 5 call 4 disable door light barrier priority travel call 3 call 2 call 1 (reserve) (reserve) (reserve) (reserve) disable door light barrier priority travel disable car panel floor level 3 back wire floor level 1 floor level 2 back wire lift travelling up lift travelling down door is open back wire Controls/Networks 2016.3 call 9 call 8 IOM-R6 call 7 call 3 call 2 IOM-R6 call 1 (reserve) keep door closed (simulate open) UIN disable car panel floor level 9 back wire keep door closed (simulate open) shut down lift IOM-R6 shut down lift general fire alarm back wire UIN floor level 7 floor level 8 back wire floor level 4 floor level 5 floor level 6 back wire general fire alarm back wire inspection flush back wire UIN inspection flush back wire smoke detector 7 smoke detector 8 smoke detector 9 back wire Coupler + floor level 3 back wire floor level 1 floor level 2 back wire 90-264VAC smoke detector 1 smoke detector 2 smoke detector 3 back wire Coupler smoke detector 6 back wire + 24V + - smoke detector 4 smoke detector 5 back wire If you need fewer inputs for smoke detectors or floor information, the lift also may have up to 13 levels without the need of additional modules. lift travelling up lift travelling down door is open back wire + 24V smoke detector 1 smoke detector 2 smoke detector 3 back wire MULTiBUS-Coupler 1.2 Dynamic fire alarm control for a lift control, which works with any voltage and logic level, up to about 3 floors The terminal assignment can be changed freely. If you need fewer inputs for smoke detectors or floor information, the lift also may have up to 7 levels without the need of additional modules. IOM-R6 Same as above, but up to about 9 levels IOM-R6 17 1.2 Controls/Networks 2016.3 MULTiBUS-Coupler MULTiBUS-Coupler as electronic lift attendant Benefit The tasks of the human lift attendant be partially replaced by the MULTiBUS-Coupler. The required weekly checks of the lift can be omitted. The inspection intervals of the human lift attendant are limited to 4 months or 30,000 travels thus for lifts with power-operated doors and for systems with manually operated doors to 2 months or 15,000 travels and can be done also by the lift mechanic as part of normal maintenance. Conditions for use • the lift must be accessible • the alarm button must be vandal-proof or testable • a remote emergency call system must exist • glazing of shaft and cabin doors must not be (in revolving doors) up to 150 mm width of • number of travels • the own parameter settings valent Upon present, with the exception of show openings laminated safety glass, wired glass or equi- • the lift must have car doors • landing doors must have fault locking safety devices or equivalent • retrofitting error detection, will be stopped. with electronic lift attendant functions are notification and inspection required What do the MULTiBUS-Coupler monitor? • that no ride happens with an open door contact or door lock • level alignments • cabin light • alarm button (in case of non vandal-proof) • remote emergency call system Detail: Monitoring the flush Detail: Monitoring the cabin lighting Switch and cam switches are included. Current sensor is included. KL cabin lighting KL - input VIO +XXXX MULTiBUS monitoring the re-level precision monitoring the stop precision (±20mm only if re-level function) optional shut-off by lift control <I> monitoring cabin lighting - input VIO -XXXX MULTiBUS closed in area ±20 mm each floor + L N current sensor flush switch at the car input VIO -XXXX MULTiBUS flush switch at the car + closed in area ±10 mm each floor MULTiBUS-Coupler warns first. If the warning is not heeded, the lift any remote alarm device with output for "connection established" -emergency call supply 18 alarm button with electro-mechanical actuation any remote alarm device with output for "connection established" pictograms in the cabin please speak connection setup emerg. call test output VIO +XXXX MULTiBUS +emergency call supply input VIO +XXXX MULTiBUS voice connection has been established alarm button input VIO +XXXX MULTiBUS voice connection has been established output VIO +XXXX MULTiBUS emerg. call test +emergency call supply pictograms in the cabin Testable alarm button is only needed if it is not vandal-proof design. please speak (Alternative: Monitoring the alarm button and remote alarm device) Remote call device must have an output „please speak“. connection setup Detail: Monitoring the remote alarm device -emergency call supply www.strack-lift-automation.de N KL KL = optional shut-off of of cabin light by lift control cabin light www.strack-lift-automation.de lift att. test switch in cabinet door lift travelling without re-levelling inspection/return back wire control voltage monitoring stopping precision maintenance switch in cabinet door IOM-UIN alarm test lift attendant switched off in cabinet door parallel to door open button pictogram “please speek“ bottom call Coupler alarm button shut down lift monitoring cabin light emerg. phone top call L + - safe.circ. neutral coming safe.circ. cabin door safe.circ. door locks safe.circ. neutral going current sensor level indicator level indicator level indicator KL supply 24VDC from the lift control control voltage MULTiBUS-Coupler Controls/Networks 2016.3 1.2 Total circuit of electronic lift attendant Vin IOM-R6 19