Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Datasheet KH-Series Cosel Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: FORTEC Elektronik AG Hauptniederlassung Lechwiesenstr. 9 86899 Landsberg am Lech Telefon: Telefax: E-Mail: Internet: +49 (0) 8191 91172-0 +49 (0) 8191 21770 [email protected] www.fortecag.de FORTEC Elektronik AG Büro Nord Am Hasenkamp 36 22457 Hamburg FORTEC Elektronik AG Büro West Hohenstaufenring 55 50674 Köln Telefon: Telefax: E-Mail: Internet: Telefon: Telefax: E-Mail: Internet: +49 (0) 40 54 80 56 11 +49 (0) 40 54 80 56 13 [email protected] www.fortecag.de +49 (0) 221 272 273-0 +49 (0) 221 272 273-10 [email protected] www.fortecag.de FORTEC Elektronik AG Büro Wien Nuschinggasse 12 A-1230 Wien ALTRAC AG (Tochter der FORTEC): Bahnhofstraße 3 CH-5436 Würenlos Telefon: Telefax: E-Mail: Internet: Telefon: Telefax: E-Mail: Internet: +43 1 8673492-0 +43 1 8673492-26 [email protected] www.fortec.at +41 (0) 44 7446111 +41 (0) 44 7446161 [email protected] www.altrac.ch The information contained in this document has been carefully researched and is, to the best of our knowledge, accurate. However, we assume no liability for any product failures or damages, immediate or consequential, resulting from the use of the information provided herein. Our products are not intended for use in systems in which failures of product could result in personal injury. All trademarks mentioned herein are property of their respective owners. All specifications are subject to change without notice. Ordering information AC-DC Power Supplies DIN Rail Type KHEA/KHNA30F KHO 1 A 2 30 3 F 4 Recommended EMI/EMC Filter NAC-04-472-D R High voltage pulse noise type : NAP series Low leakage current type : NAM series -OO -O 5 6 1 Series name KHE:Euro style I/O terminals KHN:Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Option C : with Coating *The EMI/EMC Filter is recommended to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT KHEA/KHNA30F-5 25 5V 5A KHEA/KHNA30F-12 27.6 12V 2.3A KHEA/KHNA30F-24 31.2 24V 1.3A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 115V ACIN 230V FREQUENCY[Hz] INPUT ACIN 115V ACIN 230V INRUSH CURRENT[A] ACIN 115V *1 ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] PEAK CURRENT[A] *2 LINE REGULATION[mV] LOAD REGULATION[mV] *2 0 to +70C *3 -20 - 0C RIPPLE[mVp-p] Io=0 - 30% 0 to +70C OUTPUT RIPPLE NOISE[mVp-p] *3 -20 - 0C Io=0 - 30% 0 to +70C TEMPERATURE REGULATION[mV] -20 to +70C *5 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] PROTECTION OVERCURRENT PROTECTION CIRCUIT AND OVERVOLTAGE PROTECTION[V] OTHERS DC_OK LAMP INPUT-OUTPUT ISOLATION INPUT-PE OUTPUT-PE OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT *8 VIBRATION IMPACT KH EFFICIENCY[%] SAFETY AND AGENCY APPROVALS (At only AC input) NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *7 CASE SIZE OTHERS WEIGHT COOLING METHOD KHEA/KHNA30F-5 KHEA/KHNA30F-12 KHEA/KHNA30F-24 AC85 - 264 1f (Output derating is required) or DC120 - 370 0.45typ 0.50typ 0.55typ 0.30typ 0.30typ 0.35typ 50 / 60 (47 - 440) or DC 84.0typ 87.0typ 88.5typ 85.5typ 88.5typ 89.5typ 18typ (Io=100%)(at cold start Ta=25C) 35typ (Io=100%)(at cold start Ta=25C) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 5 12 24 5.0 2.3 1.3 20max 48max 96max 80max 100max 150max 150max 150max 150max 300max 300max 300max 300max *4 300max *4 300max *4 180max 180max 180max 360max 360max 360max 360max *4 360max *4 360max *4 50max 120max 240max 60max 150max 290max 20max 48max 96max 200typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 4.50 to 5.50 10.80 to 13.20 22.50 to 28.50 5.00 to 5.15 12.00 to 12.48 24.00 to 24.96 Works over 105% of rating and recovers automatically *10 6.30 to 7.60 13.80 to 16.80 30.00 to 36.00 LED (Green) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) -20 to +70C (Required to Derating), 20 - 90%RH (Non condensing) -30 to +85C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 196.1m/s2 (20G), 11ms, once each X, Y and Z axis (Packing state) UL60950-1, C-UL(CSA60950-1), UL508 (NEC Class2 per UL1310), ANSI/ISA12.12.01, EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2(Class A) *6(Not built-in to active filter) *9 22.5X75X90mm (WXHXD) [0.89X2.95X3.54 inches] 165g max Convection / Forced air *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is excluded. *2 Please contact us about dynamic load and input response. *3 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 2.7. Ripple and ripple noise spec is change at Io=0 to 30% by burst operation. *4 In case of operating under 0C ambient temperature, the value is two times of specification at 0 to 30% load factor. *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. KH-2 *6 Please contact us about another class. *7 Case size contains neither the umbo. *8 Only as standard mounting orientation (A). Refer to the instruction manual 5.1. If install other than standard mounting orientation (A), please fix the power supply for withstand the vibration and impact. *9 When two or more units are operating it may not comply with the IEC61000-3-2. *10 If the overcurrent protection circuit operates continuously, the output voltage shut down. Refer to the instruction manual 2.3. * To meet the specifications. Do not operate over-loaded condition. * A sound may occur from power supply at light or peak loading. KH series Block diagram FUSE 250V 2.5A AC IN 85 264V NOISE FILTER INRUSH CURRENT LIMIT RECTIFIER AND FILTER PE TRANSFORMER INVERTER CONTROL RECTIFIER AND FILTER DC OUT CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view 6.6 9.3 [0.26] [0.37] [0.19] Name plate [0.26] 9.3 11.25 [0.37] 94.5 [0.39] [3.72] [3.31] 84 10max [1.59] [2.37] (40.5) 47.5 20 [0.79] AC(L) AC(N) TB1 6.6 94.5 [3.72] PE 75 [3.31] 84 (40.5) [1.59] 60.5 ±1.5 [1.87] 47.5 6.4 [0.25] 22.5 [0.43] [0.29] PE TB1 4.9 7.25 ±1.5 [0.43] AC(L) AC(N) 75 Output terminal(-) LED(DC_OK) Output voltage adjustable potentiometer 10.9 LED(DC_OK) Output voltage adjustable potentiometer 10.9 [2.95] Output terminal(+) Output terminal(-) [2.38] Output terminal(+) 90 [3.54] 5-M3.5 60.1 ±1.5 TB2 [1.87] 90 [3.54] [0.29] 6.4 [0.25] 7.45 ±1.5 4.9 [0.19] TB2 [0.33] 8.3 ±0.1 <KHNA30F(Barrier Blocks Style I/O Terminals)> [2.95] <KHEA30F(Euro Style I/O Terminals)> Name plate [0.44] [0.89] 22.5 [0.89] ¶ Tolerance : ±1 [±0.04] ¶ Weight : 165g max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06] ¶ Chassis-Case material : PBT ¶ Din rail attachment material : PC/ABS ¶ Dimensions in mm, [ ] = inches ¶ Screw tightening torque : 1N-m max ¶ Tolerance : ±1 [±0.04] ¶ Weight : 165g max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06] ¶ Chassis-Case material : PBT ¶ Din rail attachment material : PC/ABS ¶ Dimensions in mm, [ ] = inches ¶ Screw tightening torque : 1N-m max KH-3 KH Ordering information AC-DC Power Supplies DIN Rail Type KHEA/KHNA60F KHO 1 A 2 60 3 F 4 Recommended EMI/EMC Filter NAC-04-472-D R High voltage pulse noise type : NAP series Low leakage current type : NAM series -OO -O 5 6 1 Series name KHE:Euro style I/O terminals KHN:Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Option C : with Coating *The EMI/EMC Filter is recommended to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT KHEA/KHNA60F-12 54 12V 4.5A KHEA/KHNA60F-24 60 24V 2.5A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 115V ACIN 230V FREQUENCY[Hz] INPUT ACIN 115V ACIN 230V INRUSH CURRENT[A] ACIN 115V *1 ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] PEAK CURRENT[A] *2 LINE REGULATION[mV] LOAD REGULATION[mV] *2 0 to +70C *3 -20 - 0C RIPPLE[mVp-p] Io=0 - 30% 0 to +70C OUTPUT RIPPLE NOISE[mVp-p] *3 -20 - 0C Io=0 - 30% 0 to +70C TEMPERATURE REGULATION[mV] -20 to +70C *5 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] PROTECTION OVERCURRENT PROTECTION CIRCUIT AND OVERVOLTAGE PROTECTION[V] OTHERS DC_OK LAMP INPUT-OUTPUT ISOLATION INPUT-PE OUTPUT-PE OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT *8 VIBRATION IMPACT KH EFFICIENCY[%] SAFETY AND AGENCY APPROVALS (At only AC input) NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *7 CASE SIZE OTHERS WEIGHT COOLING METHOD KHEA/KHNA60F-12 KHEA/KHNA60F-24 AC85 - 264 1f (Output derating is required) or DC120 - 370 1.00typ 1.10typ 0.60typ 0.70typ 50 / 60 (47 - 440) or DC 87.0typ 89.0typ 88.0typ 91.0typ 18typ (Io=100%)(at cold start Ta=25C) 35typ (Io=100%)(at cold start Ta=25C) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 12 24 4.5 2.5 48max 96max 100max 150max 200max 200max 300max 300max 300max *4 300max *4 260max 260max 360max 360max 360max *4 360max *4 120max 240max 150max 290max 48max 96max 200typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 22.50 to 28.50 12.00 to 12.48 24.00 to 24.96 Works over 105% of rating and recovers automatically *10 13.80 to 16.80 30.00 to 36.00 LED (Green) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) -20 to +70C (Required to Derating), 20 - 90%RH (Non condensing) -30 to +85C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 196.1m/s2 (20G), 11ms, once each X, Y and Z axis (Packing state) UL60950-1, C-UL(CSA60950-1), UL508 (NEC Class2 per UL1310), ANSI/ISA12.12.01, EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2(Class A) *6(Not built-in to active filter) *9 32X90X90mm (WXHXD) [1.26X3.54X3.54 inches] 270g max Convection / Forced air *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is excluded. *2 Please contact us about dynamic load and input response. *3 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 2.7. Ripple and ripple noise spec is change at Io=0 to 30% by burst operation. *4 In case of operating under 0C ambient temperature, the value is two times of specification at 0 to 30% load factor. *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. KH-4 *6 Please contact us about another class. *7 Case size contains neither the umbo. *8 Only as standard mounting orientation (A). Refer to the instruction manual 5.1. If install other than standard mounting orientation (A), please fix the power supply for withstand the vibration and impact. *9 When two or more units are operating it may not comply with the IEC61000-3-2. *10 If the overcurrent protection circuit operates continuously, the output voltage shut down. Refer to the instruction manual 2.3. * To meet the specifications. Do not operate over-loaded condition. * A sound may occur from power supply at light or peak loading. KH series Block diagram FUSE 250V 3.15A AC IN 85 264V INRUSH CURRENT LIMIT NOISE FILTER RECTIFIER AND FILTER PE TRANSFORMER INVERTER CONTROL RECTIFIER AND FILTER DC OUT CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view 8.3 ±0.1 <KHNA60F(Barrier Blocks Style I/O Terminals)> 6.5 6.4 90 6.7 9.3 [0.25] [0.25] [3.54] [0.26] [0.37] TB2 90 6-M3.5 [3.54] TB2 Output terminal(+) Output terminal(-) 99 90 [3.9] [1.89] 60 [3.54] (48) (48) AC(N) PE [2.36] 99 [3.9] 90 [3.54] Output voltage adjustable potentiometer AC(L) [1.89] AC(N) PE TB1 [2.97] 75.5 ±1.5 60 AC(L) [2.36] Output voltage adjustable potentiometer 75.1±1.5 Output terminal(-) LED(DC_OK) [2.96] Output terminal(+) LED(DC_OK) 9.3 6.7 Name plate [0.26] [0.37] 11.2 [0.44] 32 [1.26] 94.5 [0.29] [3.72] 7.45 ±1.5 [0.44] [0.37] 94.5 [0.29] 11.2 7.25 ±1.5 TB1 9.5 6.5 [0.26] [0.33] <KHEA60F(Euro Style I/O Terminals)> [3.72] Name plate 32 [1.26] ¶ Tolerance : ±1 [±0.04] ¶ Weight : 270g max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06] ¶ Chassis-Case material : PBT ¶ Din rail attachment material : PC/ABS ¶ Dimensions in mm, [ ] = inches ¶ Screw tightening torque : 1N-m max ¶ Tolerance : ±1 [±0.04] ¶ Weight : 270g max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06] ¶ Chassis-Case material : PBT ¶ Din rail attachment material : PC/ABS ¶ Dimensions in mm, [ ] = inches ¶ Screw tightening torque : 1N-m max KH-5 KH Ordering information AC-DC Power Supplies DIN Rail Type KHEA/KHNA90F KHO 1 A 2 90 3 F 4 Recommended EMI/EMC Filter NAC-04-472-D R High voltage pulse noise type : NAP series Low leakage current type : NAM series -OO -O 5 6 1 Series name KHE:Euro style I/O terminals KHN:Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Option C : with Coating E : NEC Class2 (24V) *The EMI/EMC Filter is recommended to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT KHEA/KHNA90F-12 81.6 12V 6.8A KHEA/KHNA90F-24 91.2 24V 3.8A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 115V ACIN 230V ACIN 115V POWER FACTOR (Io=100%) ACIN 230V INRUSH CURRENT[A] ACIN 115V *1 ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] PEAK CURRENT[A] *2 LINE REGULATION[mV] LOAD REGULATION[mV] *2 0 to +70C *3 -20 - 0C RIPPLE[mVp-p] Io=0 - 30% 0 to +70C OUTPUT RIPPLE NOISE[mVp-p] *3 -20 - 0C Io=0 - 30% 0 to +70C TEMPERATURE REGULATION[mV] -20 to +70C *5 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] PROTECTION OVERCURRENT PROTECTION CIRCUIT AND OVERVOLTAGE PROTECTION[V] OTHERS DC_OK LAMP INPUT-OUTPUT INPUT-PE ISOLATION OUTPUT-PE OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT *8 VIBRATION IMPACT INPUT KH EFFICIENCY[%] SAFETY AND AGENCY APPROVALS (At only AC input) NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *7 CASE SIZE OTHERS WEIGHT COOLING METHOD KHEA/KHNA90F-12 KHEA/KHNA90F-24 AC85 - 264 1f (Output derating is required) or DC88-250 *10 0.85typ 0.95typ 0.45typ 0.55typ 50 / 60 (47 - 63) or DC 87.0typ 89.0typ (88.0typ for option -E) 88.0typ 91.0typ (89.5typ for option -E) 0.98typ 0.86typ 18typ (Io=100%)(at cold start Ta=25C) 35typ (Io=100%)(at cold start Ta=25C) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 12 24 6.8 3.8 48max 96max 100max 150max 200max 200max 300max 300max 300max *4 300max *4 260max 260max 360max 360max 360max *4 360max *4 120max 240max 150max 290max 48max 96max 500typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 22.50 to 28.50 (Fixed for option -E) 12.00 to 12.48 24.00 to 24.96 (24.00 to 24.50 for option -E) Works over 105% of rating (101% for option -E), recovers automatically *9 13.80 to 16.80 30.00 to 36.00 (26.40 to 33.60 for option -E) LED (Green) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) -20 to +70C (Required to Derating), 20 - 90%RH (Non condensing) -30 to +85C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 196.1m/s2 (20G), 11ms, X, Y and Z axis (Packing state) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178, UL508, NEC Class2 (24V output only option -E), ANSI/ISA12.12.01 Compliies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2(Class A) *6 50X90X90mm (WXHXD) [1.97X3.54X3.54 inches] 405g max Convection / Forced air *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is excluded. *2 Please contact us about dynamic load and input response. *3 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 2.7. Ripple and ripple noise spec is change at Io=0 to 30% by burst operation. *4 In case of operating under 0C ambient temperature, the value is two times of specification at 0 to 30% load factor. *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. KH-6 *6 Please contact us about another class. *7 Case size contains neither the umbo. *8 Only as standard mounting orientation (A). Refer to the instruction manual 5.1. If install other than standard mounting orientation (A), please fix the power supply for withstand the vibration and impact. *9 If the overcurrent protection circuit operates continuously, the output voltage shut down. Refer to the instruction manual 2.3. *10 Under low DC input voltage below DC110V, the temperature derating -1C/V or the output power derating -1%/V are required. * To meet the specifications. Do not operate over-loaded condition. * A sound may occur from power supply at light or peak loading. KH series Block diagram FUSE 250V 3.15A AC IN 85 NOISE FILTER 264V INRUSH CURRENT LIMIT RECTIFIER PE TRANSFORMER CONTROL BOOSTER INDUCTOR CURRENT SENSING INVERTER RECTIFIER AND FILTER RECTIFIER AND FILTER DC OUT CURRENT SENSING Photocoupler INVERTER CONTROL Photocoupler OVER VOLTAGE PROTECTION CONTROL External view 8.3 ±0.1 <KHNA90F(Barrier Blocks Style I/O Terminals)> 15.5 6.4 90 [0.61] [0.25] [3.54] Output terminal(+) Output terminal(-) LED(DC_OK) Output voltage adjustable potentiometer TB2 15.7 9.3 [0.62] [0.37] 90 [3.54] 6-M3.5 [0.44] 9.3 [0.62] [0.37] 11.2 [0.44] 50 [1.97] [3.9] 99 (48) [1.89] 90 [3.54] [2.96] 75.1 ±1.5 60 15.7 [2.36] (48) [1.89] Name plate 94.5 [0.29] 99 [3.9] 90 94.5 [3.72] AC(N) PE TB1 7.45 ±1.5 [0.37] 11.2 [3.54] 75.5 ±1.5 9.5 [0.61] [0.29] 60 15.5 Output voltage adjustable potentiometer AC(L) [2.36] AC(L) AC(N) PE TB1 [2.97] Output terminal(+) Output terminal(-) LED(DC_OK) 7.25 ±1.5 TB2 [0.33] <KHEA90F(Euro Style I/O Terminals)> [3.72] Name plate 50 [1.97] KH ¶ Tolerance : ±1 [±0.04] ¶ Weight : 405g max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06] ¶ Chassis-Case material : PBT ¶ Din rail attachment material : PC/ABS ¶ Dimensions in mm, [ ] = inches ¶ Screw tightening torque : 1N-m max ¶ Tolerance : ±1 [±0.04] ¶ Weight : 405g max ¶ PCB Material/thickness : FR-4 / 1.6mm [0.06] ¶ Chassis-Case material : PBT ¶ Din rail attachment material : PC/ABS ¶ Dimensions in mm, [ ] = inches ¶ Screw tightening torque : 1N-m max KH-7 Ordering information AC-DC Power Supplies DIN Rail Type KHEA/KHNA120F KHO 1 A 2 -120 3 F 4 Recommended EMI/EMC Filter NAC-04-472-D R High voltage pulse noise type : NAP series Low leakage current type : NAM series -24 5 -O 6 1 Series name KHE:Euro style I/O terminals KHN:Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Option C : with Coating N2 : Screw mounting *The EMI/EMC Filter is recommended to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT KHEA / KHNA120F-24 120 24V 5A (Peak 7.5A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 115V ACIN 230V ACIN 115V POWER FACTOR ACIN 230V INRUSH CURRENT[A] ACIN 115V *1 ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] *2 PEAK CURRENT[A] *3 LINE REGULATION[mV] LOAD REGULATION[mV] *3 0 to +70C *5 -25 - 0C RIPPLE[mVp-p] Io=0 - 30% 0 to +70C OUTPUT RIPPLE NOISE[mVp-p] *5 -25 - 0C Io=0 - 30% 0 to +70C TEMPERATURE REGULATION[mV] -25 to +70C *6 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND DC_OK LAMP OTHERS ALARM LAMP DC_OK CONTACT INPUT-OUTPUT INPUT-PE ISOLATION OUTPUT-PE OUTPUT-RC, DC_OK OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT *9 VIBRATION IMPACT SAFETY AND AGENCY APPROVALS (At only AC input) CONDUCTED NOISE NOISE REGULATIONS HARMONIC ATTENUATOR *8 CASE SIZE OTHERS WEIGHT COOLING METHOD INPUT KH EFFICIENCY[%] KHEA / KHNA120F-24 AC85 - 264 1f or DC88 - 370 *10 1.2typ 0.6typ 50 / 60 (47 - 63) or DC 90typ 92typ 0.98typ 0.93typ 15typ (at cold start Ta=25C) 30typ (at cold start Ta=25C) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 5 7.5 96max 150max *4 120max 240max 240max *4 150max 300max 300max *4 240max *4 360max *4 96max 750max (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 22.5 to 28.5 24.0±1.0% Works over 101% of peak current and recovers automatically 30.0 to 36.0 LED (Green) LED (Red) Relay contact 30VDC 1A max, 30VAC 0.5A max (resistive load) (Only KHEA) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) -25 to +70C (Required to Derating), 20 - 90%RH (Non condensing) -40 to +85C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 196.1m/s2 (20G), 11ms, once each X, Y and Z axis (Packing state) UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508, ANSI / ISA12.12.01 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2(Class A) *7 37X124X117mm (WXHXD) [1.46X4.88X4.61 inches] 580g max Convection / Forced air *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is excluded. *2 Refer to 3, instruction manual. *3 Please contact us about dynamic load and input response. *4 The output voltage is below 23.5V, the value is equal to three times of the specification. *5 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. KH-8 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 2.7. *6 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/ output. *7 Please contact us about another class. *8 Case size contains neither the umbo. *9 Only as standard mounting orientation (A). Refer to the instruction manual 5.1. If install other than standard mounting orientation (A), please fix the power supply for withstand the vibration and impact. *10 Under low DC input voltage below DC110V, the temperature derating -1C/V or the output power derating -1%/V are required. * To meet the specifications. Do not operate over-loaded condition. * A sound may occur from power supply at light or peak loading. KH series Block diagram FUSE 250V 5A NOISE FILTER AC IN 85∼264V RECTIFIER PE BOOSTER INDUCTOR CURRENT SENSING INRUSH CURRENT LIMIT TRANSFORMER RECTIFIER AND FILTER INVERTER RECTIFIER AND FILTER DC OUT INVERTER CURRENT SENSING Photocoupler OVER VOLTAGE PROTECTION CONTROL Photocoupler CONTROL CONTROL PhotoMosRelay DC_OK (Only KHEA) Photocoupler RC (Remote ON/OFF) External view <KHEA120F(Euro Style I/O Terminals)> -RC <KHNA120F(Barrier Blocks Style I/O Terminals)> -RC +RC 9 6.4 111.2 8.5 10 [0.35] [0.25] [4.38] [0.33] [0.39] 6-M4 +RC 2 111.2 [0.08] [4.38] Output terminal(+) DC_OK Output terminal(+) Output terminal(-) 8.5 [0.37] [4.77] [0.33] 10 [0.39] [5.26] 133.5 (65.7) [2.59] [4.88] 124 [4.15] 105.4 [0.61] [0.37] 69 15.5 121.2 Name plate [2.72] 9.3 117 [4.61] AC(L) AC(N) PE 9.5 9 [0.35] [0.30] 7.5 PE [0.61] [5.26] 133.5 (65.7) AC(N) 15.5 LED(ALARM) LED(DC_OK) Output voltage adjustable potentiometer [2.59] 124 [4.88] 109 69 AC(L) Name plate [2.72] Output voltage adjustable potentiometer [4.29] Output terminal(-) LED(ALARM) LED(DC_OK) 117 [4.61] 121.2 [4.77] KH 37 37 [1.46] [1.46] Tolerance : ±1 [±0.04] Weight : 580g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel DIN rail attachment material : Aluminum, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1N m max Tolerance : ±1 [±0.04] Weight : 580g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel DIN rail attachment material : Aluminum, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1.6N m max KH-9 Ordering information AC-DC Power Supplies DIN Rail Type KHEA/KHNA240F KHO 1 A 2 -240 3 F 4 Recommended EMI/EMC Filter NAC-06-472-D R High voltage pulse noise type : NAP series Low leakage current type : NAM series -24 5 -O 6 1 Series name KHE:Euro style I/O terminals KHN:Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Option C : with Coating N2 : Screw mounting *The EMI/EMC Filter is recommended to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT KHEA / KHNA240F-24 240 24V 10A (Peak 15A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 115V ACIN 230V ACIN 115V POWER FACTOR ACIN 230V INRUSH CURRENT[A] ACIN 115V *1 ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] *2 PEAK CURRENT[A] *3 LINE REGULATION[mV] LOAD REGULATION[mV] *3 0 to +70C *5 -25 - 0C RIPPLE[mVp-p] Io=0 - 30% 0 to +70C OUTPUT RIPPLE NOISE[mVp-p] *5 -25 - 0C Io=0 - 30% 0 to +70C TEMPERATURE REGULATION[mV] -25 to +70C *6 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND DC_OK LAMP OTHERS ALARM LAMP DC_OK CONTACT INPUT-OUTPUT INPUT-PE ISOLATION OUTPUT-PE OUTPUT-RC, DC_OK OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT *9 VIBRATION IMPACT SAFETY AND AGENCY APPROVALS (At only AC input) CONDUCTED NOISE NOISE REGULATIONS HARMONIC ATTENUATOR *8 CASE SIZE OTHERS WEIGHT COOLING METHOD INPUT KH EFFICIENCY[%] KHEA / KHNA240F-24 AC85 - 264 1f or DC88 - 370 *10 2.3typ 1.2typ 50 / 60 (47 - 63) or DC 92typ 94typ 0.98typ 0.93typ 20typ (more than 3 sec. to re-start) 40typ (more than 3 sec. to re-start) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 10 15 96max 150max *4 120max 240max 240max *4 150max 300max 300max *4 240max *4 360max *4 96max 750max (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 22.5 to 28.5 24.0±1.0% Works over 101% of peak current and recovers automatically 30.0 to 36.0 LED (Green) LED (Red) Relay contact 30VDC 1A max, 30VAC 0.5A max (resistive load) (Only KHEA) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) -25 to +70C (Required to Derating), 20 - 90%RH (Non condensing) -40 to +85C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 196.1m/s2 (20G), 11ms, once each X, Y and Z axis (Packing state) UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508, ANSI / ISA12.12.01 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2(Class A) *7 50X124X117mm (WXHXD) [1.97X4.88X4.61 inches] 900g max Convection / Forced air *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is excluded. *2 Refer to 3, instruction manual. *3 Please contact us about dynamic load and input response. *4 The output voltage is below 23.5V, the value is equal to three times of the specification. *5 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. KH-10 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 2.7. *6 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/ output. *7 Please contact us about another class. *8 Case size contains neither the umbo. *9 Only as standard mounting orientation (A). Refer to the instruction manual 5.1. If install other than standard mounting orientation (A), please fix the power supply for withstand the vibration and impact. *10 Under low DC input voltage below DC110V, the temperature derating -1C/V or the output power derating -1%/V are required. * To meet the specifications. Do not operate over-loaded condition. * A sound may occur from power supply at light or peak loading. KH series Block diagram FUSE 250V 8A NOISE FILTER AC IN 85∼264V RECTIFIER PE BOOSTER INDUCTOR CURRENT SENSING INRUSH CURRENT LIMIT TRANSFORMER RECTIFIER AND FILTER INVERTER RECTIFIER AND FILTER DC OUT INVERTER CURRENT SENSING Photocoupler OVER VOLTAGE PROTECTION CONTROL Photocoupler CONTROL CONTROL PhotoMosRelay DC_OK (Only KHEA) Photocoupler RC (Remote ON/OFF) External view <KHEA240F(Euro Style I/O Terminals)> -RC 9.1 6.4 [0.36] [0.25] <KHNA240F(Barrier Blocks Style I/O Terminals)> -RC +RC 111.2 [4.38] DC_OK Output terminal(+) Output terminal(-) 10 10 [0.39] [0.39] 7-M4 +RC 2 111.2 [0.08] [4.38] 9.5 15.5 [0.61] 50 [0.37] 117 [4.61] 121.2 [4.77] 15.5 [0.61] 15 [0.59] 10 [0.39] 50 [5.26] 133.5 (65.7) [2.59] [4.88] [4.15] 124 105.4 Name plate PE [0.37] [0.30] 7.5 PE AC(L) AC(N) 69 [2.59] AC(N) (65.7) 69 AC(L) [2.72] Output voltage adjustable potentiometer LED(ALARM) LED(DC_OK) Output voltage adjustable potentiometer [2.72] 124 [4.88] 109 [4.29] LED(DC_OK) 9.3 Name plate LED(ALARM) [5.26] 133.5 Output terminal(+) Output terminal(-) 117 KH [4.61] 121.2 [4.77] [1.97] [1.97] Tolerance : ±1 [±0.04] Weight : 900g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel DIN rail attachment material : Aluminum, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1N m max Tolerance : ±1 [±0.04] Weight : 900g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel DIN rail attachment material : Aluminum, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1.6N m max KH-11 Ordering information AC-DC Power Supplies DIN Rail Type KHEA/KHNA480F KHO 1 A 480 2 3 F 4 Recommended EMI/EMC Filter NAC-10-472-D R High voltage pulse noise type : NAP series Low leakage current type : NAM series -OO -O 5 6 1 Series name KHE:Euro style I/O terminals KHN:Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Option C : with Coating N2 : Screw mounting *The EMI/EMC Filter is recommended to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT KHEA / KHNA480F-24 480 24V 20A (Peak 30A) KHEA / KHNA480F-48 480 48V 10A (Peak 15A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 115V ACIN 230V ACIN 115V POWER FACTOR ACIN 230V INRUSH CURRENT[A] ACIN 115V *1 ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] *2 PEAK CURRENT[A] *3 LINE REGULATION[mV] LOAD REGULATION[mV] *3 0 to +70C *4 -25 - 0C RIPPLE[mVp-p] Io=0 - 30% 0 to +70C OUTPUT RIPPLE NOISE[mVp-p] *4 -25 - 0C Io=0 - 30% 0 to +70C TEMPERATURE REGULATION[mV] -25 to +70C *5 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND DC_OK LAMP OTHERS ALARM LAMP DC_OK CONTACT INPUT-OUTPUT INPUT-PE ISOLATION OUTPUT-PE OUTPUT-RC, DC_OK OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT *8 VIBRATION IMPACT SAFETY AND AGENCY APPROVALS (At only AC input) CONDUCTED NOISE NOISE REGULATIONS HARMONIC ATTENUATOR *7 CASE SIZE OTHERS WEIGHT COOLING METHOD INPUT KH EFFICIENCY[%] KHEA / KHNA480F-24 KHEA / KHNA480F-48 AC85 - 264 1f (Output derating is required) or DC88 - 350 *10 4.6typ 2.3typ 50 / 60 (47 - 63) or DC 92typ 94typ 0.98typ 0.93typ 20typ (more than 3 sec. to re-start) 40typ (more than 3 sec. to re-start) 0.75 / 1.5max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 48 20 10 30 15 96max (Io=30-100%) *9 192max (Io=30-100%) *9 150max (Io=30-100%) *9 300max (Io=30-100%) *9 120max 120max 240max 240max 500max 750max 150max 150max 300max 300max 600max 750max 240max 480max 360max 600max 96max 192max 750max (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 22.5 to 26.4 45.0 to 55.2 24.0±1.0% 48.0±1.0% Works over 101% of peak current and recovers automatically 30.0 to 36.0 57.6 to 67.2 LED (Green) LED (Red) Relay contact 30VDC 1A max, 30VAC 0.5A max (resistive load) (Only KHEA) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min(At Room Temperature) -25 to +70C (Required to Derating), 20 - 90%RH (Non condensing) -40 to +85C, 20 - 90%RH (Non condensing) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 196.1m/s2 (20G), 11ms, once each X, Y and Z axis (Packing state) UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508, ANSI / ISA12.12.01 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2(Class A) *6 70X124X117mm (WXHXD) [2.76X4.88X4.61 inches] 1,200g max Convection / Forced air *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is excluded. *2 Refer to 3, instruction manual. *3 Please contact us about dynamic load and input response. *4 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). KH-12 Please refer to the instruction manual 2.7. *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/ output. *6 Please contact us about another class. *7 Case size contains neither the umbo. *8 Only as standard mounting orientation (A). Refer to the instruction manual 5.1. If install other than standard mounting orientation (A), please fix the power supply for withstand the vibration and impact. *9 Burst operation at 30% load or less. *10 Under low DC input voltage below DC110V, the temperature derating -1C/V or the output power derating -1%/V are required. * To meet the specifications. Do not operate over-loaded condition. * A sound may occur from power supply at light or peak loading. KH series Block diagram FUSE 250V 15A NOISE FILTER AC IN 85∼264V RECTIFIER INRUSH CURRENT LIMIT PE BOOSTER INDUCTOR CURRENT SENSING RECTIFIER AND FILTER TRANSFORMER INVERTER RECTIFIER AND FILTER DC OUT INVERTER CURRENT SENSING Photocoupler OVER VOLTAGE PROTECTION CONTROL Photocoupler CONTROL CONTROL PhotoMosRelay DC_OK (Only KHEA) Photocoupler RC (Remote ON/OFF) External view <KHEA480F(Euro Style I/O Terminals)> <KHNA480F(Barrier Blocks Style I/O Terminals)> -RC +RC 27.1 6.4 [1.07] [0.25] -RC +RC 111.2 [4.38] DC_OK Output terminal(+) Output terminal(-) LED(ALARM) LED(DC_OK) Output voltage adjustable potentiometer 30.4 10 [1.2] [0.39] 7-M4 2 111.2 [0.08] [4.38] 25.5 9.5 [1] [0.37] 70 121.2 [4.77] [2.76] 16.5 [0.65] 25 10 [0.98] [0.39] 70 [5.26] 133.5 (65.7) [2.59] 124 [4.15] [0.37] 69 9.3 (65.7) 117 [4.61] AC(L) AC(N) PE [4.88] 105.4 Name plate [2.72] [5.26] 133.5 LED(ALARM) LED(DC_OK) Output voltage adjustable potentiometer [2.59] 124 [4.88] 109 [0.65] [0.3] 69 7.5 16.5 Name plate [2.72] AC(L) AC(N) PE [4.29] Output terminal(+) Output terminal(-) 117 [4.61] KH 121.2 [4.77] [2.76] Tolerance : ±1 [±0.04] Weight : 1,200g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel DIN rail attachment material : Aluminum, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1N m max Tolerance : ±1 [±0.04] Weight : 1,200g max PCB Material/thickness : FR-4 / 1.6mm [0.06] Chassis material : Aluminum Case material : Stainless steel DIN rail attachment material : Aluminum, Nylon Dimensions in mm, [ ] = inches Screw tightening torque : 1.6N m max KH-13 Our company network supports you ou w worldwide with offices in Germany, Austria, Swit witzerland, Great Britain and the USA. For more information n pl please contact: FOR ORTEC Elektronik AG Haup auptniederlassung Lech echwiesenstr. 9 8689 6899 Landsberg am Lech Telef elefon: Telef elefax: E-Ma Mail: Inter nternet: +49 (0) 8191 91172-0 +49 (0) 8191 21770 [email protected] www.fortecag.de FORTEC Elektronik ik A AG Büro Nord Am Hasenkamp 36 22457 Hamburg FORTEC Elektronik AG Büro West Hohenstaufenring 55 50674 Köln Telefon: Telefax: E-Mail: Internet: Telefon: Telefax: E-Mail: Internet: +49 (0) 40 54 80 56 11 +49 (0) 40 54 80 56 13 nord@forte ortecag.de www.fortec rtecag.de +49 (0) 221 21 272 273-0 +49 (0) 221 21 272 273-10 west@forteca tecag.de www.fortecag ecag.de FORTEC Elektronik ik A AG Büro Wien Nuschinggasse 12 A-1230 Wien ALTRAC AG (Tochter der Fortec AG): G): Bahnhofstraße 3 CH-5436 Würenlos Telefon: Telefax: E-Mail: Internet: Telefon: Telefax: E-Mail: Internet: +43 1 8673492-0 8673 +43 1 8673492-26 8673 office@fort fortec.at www.fortec rtec.at Membe mbers of the +41 (0) 44 4 7446111 7 +41 (0) 44 4 7446161 7 [email protected] ac.ch www.altrac.c ac.ch Group: