MODULAR SOLID STATE POWER AMPLIFIER 1500 W
S BAND (RF20252120 - 1500)
•
1500W output power @ 1 dB compression
•
4 hot swappable and fully front panel interchangeable 500W drawers
•
Power supply unit for each 500W drawer
•
•
•
Standard 19” - 38U(1.9 m with wheels) cabinet
•
•
•
•
60 dB minimum gain (20 dB adjustment by 0.1 dB step)
Fully remote control by Ethernet option/fix IP number
(RS232 or RS485 in option)
-50 dBc RF output sample port
3U main power supply drawer
Temperature protection
Front panel monitoring (LCD display) and control
1500W SSPA architecture
1
2
3
4
RF 20252120-500/A1
RF in 0dBm
D
1
D
RF 20252120-500/A2
2
RF 20252120-COM
-50dBc Sample out
Sampling
Attenuator
1
Band Pass Filter
2
Power Combiner
C
Power Spl itter
RF 20252120-15A
RF 20252120-500/A3
RF out
C
RF 20252120-500/A4
B
B
RS485
Control Board
ETERNET
RF Power Sensor
Pfwd
Prev
ABCDEF
ABCDEF
PSU
A
Title
LCD Display
Keyboard
Size
A4
RF20252120 MONITORING
1
Parc d'activité de Fontaudin
F33370 Artigues près Bordeaux
FRANCE
Date:
File:
2
3
Number
RF20252120-1500
Revision
Block Diagram
25-Jul-2006
She et of
\\Efg80\disk 1\Fre d\Protel\Synop Baie Chine\Baie
Dra wn By:
Chine.Bkp
A
A
1/1
FD
4
Distributed by:
AA SYSTEL France
9, rue RAVEL, 91620 NOZAY / France
TEL: + 33 1 6963 8630
FAX: + 33 1 6963 8474
E-mail: [email protected]
Beijing mobile: +86 138 010 11504
RF20252120 - 1500 Specifications
Characteristics
Data
Units
2025 - 2120
MHz
RF output power CW at 1 dB compression
1500
W
RF output power CW (saturated)
1600
W
60
dB
Gain variation in band
< +/-1.5
dB
Gain stability after warming up & ALC ON
< +/-0.5
dB/24H
Gain stability over temperature with ALC ON
< +/- 1.5
dB/24H
Frequency range
Power gain min.
Gain control
Over 20 dB by 0.1 dB step
In/Out impedances nom.
50
Input VSWR
1.25 : 1
output VSWR
1.35 : 1
Load VSWR for rated output power
Protection circuits
Ohms
up to 1.5 : 1
Load VSWR, over-temperature, over voltage
Harmonics typ.
-60
dBc
Spurious typ.
-60
dBc
< -90
dBm/Hz
2°/dB @ 1dB back-off and 1°/dB @ 3dB back-off
°/dB
-26 dBc @ 3 dB back-off from P1 dB
dBc
over 25
dB
10
dB
Noise in bandwidth (TX) (full gain)
AM/PM conversion
Two tones intermodulation (5 MHz delta)
Input gain control (gain adjustment)
Noise Figure typ.
In/Out RF connectors
N female (In) 7/16 female or WR430** (Out)
** upon request
Cooling
Forced air (self-contained fans)
Humidity
up to 85
%
Operating temperature range
10 to +35
°C
-25 to +65
°C
2000
m
Storage temperature range
Altitude
Power supply
230 AC or 380 ** +/- 10 %, 47-63 Hz
Power consumption typ.
6 200 typ.
Dimensions (W x H x D)
19’’ x 38 U (1.9 m with wheels) x 0.8m cabinet
≤ 220 kg
Weight (typical)
Monitoring & Control
Local : Front panel LCD/Keyboard (4U)
Remote : Ethernet / E-mail alarms messenger
All data at room temperature +22°C, into 50 Ohms, subject to change without notice.
Parc d'activité de Fontaudin
F33370 Artigues près Bordeaux
FRANCE
V
VA
** upon request
OPTIONS
OPTION 1 : SSPA provided with Ethernet interface
RS485 or RS232 as base line in option.
OPTION 2 : Antenna / Dummy Load Switch
A switch at the system output can be used for maintenance purpose.
This allows operation of the system either into the antenna, or into the dummy load. This switch
is controlled and monitored in Local and Remote modes.
IMPORTANT : the dummy load is located outside the cabinet
OPTION 3 : RF Input Switch (On-Line/Standby modes)
This switch at the system RF input is used to set-up the system either in On-Line or
Standby mode. This switch is controlled and monitored in Local and Remote modes.
OPTION 4 : ALC (Automatic Level Control)
This option allows the operator to set-up the output power at a defined level. When ALC
mode is selected, the gain adjustment is automatically inactive.
This ALC is controlled and monitored in Local and Remote modes.
OPTION 5 : Power output through WR430 waveguide
OPTION 6: Redundant pre-amplifier
Parc d'activité de Fontaudin
F33370 Artigues près Bordeaux
FRANCE