Type PPU Generator Paralleling and Protection Unit multi-line 2 4921240193F • Compact system in one unit • Generator synchronisation, protection and control • True 3-phase RMS measurements • Easy-readable display • Separate display PPU Application The PPU generator controller is a microprocessorbased control unit containing all necessary functions for control of a synchronous generator. The PPU can synchronise the generator and after synchronisation carry out all necessary generator control and protective functions. The PPU contains all necessary 3-phase measuring circuits and presents all values and alarms on the LC display. Programming is easily done via a menu structure in the display (password protected) or via the RS232 PC connection and the multi-line 2 Windows® based service software. The service software offers additional features such as monitoring of all relevant information during commissioning, saving/download of settings and download of software updates. The PPU is a compact all-in-one unit designed for generators running: - stand-alone - parallel with other generators - parallel with the mains The PPU is well-suited for PLC-controlled systems, interfacing can be done via binary and analogue I/O’s or via (optional) serial communication. The PPU carries out a cyclical self-test, displaying error messages in clear text and indicating errors with relay outputs, should any errors occur. Display DEIF A/S The display is separate, for mounting directly on the PPU or in the panel front, connected via cable (option J). Standard functions Synchronisation - frequency control with programmable slip freq. - voltage matching possible - breaker ON pulse at exact sync. point with programmable generator breaker delay time - “black busbar” operation of generator breaker possible Power or frequency control The PPU can control the power or frequency in 4 different modes with selection of internal (programmable) or external +/- 10 VDC set point. By combining these all operation schemes of a generator can be implemented. The modes are selected via binary inputs or (optional) serial interface. - fixed frequency (standalone running) - fixed power (parallel with mains) - droop (controlled frequency drop with increasing load) - load sharing (generators in parallel, island operation) The PPU performs programmable ramp-up and rampdown of the power in connection with breaker operations. Generator protection All protection functions have definite time characteristic. Inverse time characteristic can be chosen for: - overcurrent (2 levels) - reverse power 4 programmable relay outputs for alarm/trip. Measured and calculated values Generator: - voltage (3-phase U + N) - current (3-phase I) - active power (kW) - reactive power (kvar) - power factor (cos ϕ) - frequency (f) - energy production (kWh) Busbar: - voltage (3-phase U) - frequency (f) Options - Loss of mains protection package Busbar protection package Generator add-on protection package Voltage/var/cos ϕ control Analogue controller outputs Analogue transducer output Start/stop relay outputs Serial communication Display cable with plugs, 3 m. User’s manual (hard copy) Display gasket for IP54 Principle diagram Type PPU Protection: Unit: IP20 Display: IP52 (IP54 with gasket: option L) To IEC 529 and EN 60529 Approvals: The PPU is approved by the major classification societies. Contact Deif for details. Governors: Multi-line 2 interfaces to all governors, including GAC, Barber-Colman, Woodward and Cummins. See application notes at www.deif.com or request doc. no. 4189340149 from DEIF. Options For available options – please see doc. no. 4921240240. Technical specifications Accuracy: Class 1.0, to IEC 688 Operating temp.: -20…70οC Climate: Class HSE, to DIN 40040 Meas. voltage: 100/110V AC (1) to 690V AC (4) +/- 20%. Consumption max. 0.15VA / phase. Meas. current: -/1 or -/5A AC. Consumption max. 0.3VA / phase. Current overload: 4 x In continuously 20 x In , 10 sec. (max. 75A) 80 x In , 1 sec. (max. 300A) Meas. frequency: 30…70Hz Aux. supply: 24V DC –25/+30 % max. 8W consumption Binary inputs: Optocoupler, bi-directional Input voltage 12…32V DC, impedance max. 2.4kΩ Relay outputs: 250V AC / 24V DC, 8A (Unit status output: 1A) Unit: H x W x D = 120 x 230 x 165 mm Display: H x W x D: 115 x 220 x 20 mm Open collector outputs: Supply 12…32V DC, max. 10 mA Analogue inputs: -10…0…+10V DC not galvanically separated Impedance max 100kΩ Mounting: DIN-rail mount or base mount. Load sharing lines: -10…0…+10V DC Analogue outputs: 0(4)...20mA Galvanically separated Active output (internal supply) Load max. 500Ω Safety: To EN 61010-1, installation category (overvoltage category) III, 600V, pollution degree 2 Galvanic separation: Between AC voltage, AC current and other I/O’s: 3250V AC, 50Hz, 1 min. Between analogue outputs: 500V DC, 1 min. EMC/CE: To EN 50081-1/2, EN 50082-1/2 SS4631503 (PL4) and IEC 255-3 Material: All plastic materials are selfextinguishing acc. to UL94 (V1) Plug connections: AC current: 4 mm multi stranded Other: 2.5 mm2 multi stranded Display: 9-pole Sub-D female PC: 9-pole Sub-D male 2 Order specifications Errors and changes excepted. DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: [email protected], URL: www.deif.com