Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Telecommunications engineering wikipedia , lookup
Audio power wikipedia , lookup
Electrification wikipedia , lookup
Electric power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Alternating current wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power engineering wikipedia , lookup
Mains electricity wikipedia , lookup
V-Line® Gen2 V2355 Installation Guide V-Line® Gen2 V2355 Installation Guide INTRODUCTION The following installation guide has been assembled to assist in planning, installing and wiring of the V-Line® Gen2 V2355 Fixture. Please read the following instructions carefully prior to installing the fixtures. Should you have any questions or require project consultation, please contact us prior to specifying or installing any i2Systems Product. Available Resources In Addition To This Guide Include: Thank you for your purchase of i2Systems V-Line® Gen2 LED fixture! – V-Line® Gen2 V2355 Datasheet* – Power Box PS24V75W-E05P / E05PW Datasheet* – V-Line® Gen2 V2355 Instruction Sheet (included with every fixture shipped) – Power Box PS28V350W-E10P / E10PH Datasheet* – i2Systems Technical Support (9am - 5pm EST) +1.860.567.0708 or [email protected] – LightLink LL-205 Installation Guide* *Available at www.i2systems.com Questions? We are here to help. Call us directly at +1.860.567.0708. ELECTRICAL WARNINGS FIXTURE MAINTENANCE • • All Products must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. • Do not attempt to install or use a Product until you have read and understand the installation instructions and safety labels. Clean the fixture with mild soap and water only. Ensure that any cleaning products that you use on the optic do not contain plasticizers as they can damage the optic. • Do not clean the fixture with high pressure washers or pointed objects as they can damage the Product and cause potential breaches of seals. • Products have risk of shock and no user-serviceable parts. Do not attempt to disassemble the light fixture in any way. • Do not submerse the Product when cleaning, or allow to sit in standing water. • Never exceed the maximum voltage rating of the Product. CERTIFICATIONS • When installing or servicing the Product, be sure to disconnect the power prior to beginning work. Do not make live connections, also known as hot-swapping. Ensure that power to the Product is off before connecting or disconnecting individual units. • Maximum plug together for Standard Output (V2355B) is 50 feet of fixtures. Maximum plug together for High Output (V2355A) is 25 feet of fixtures. Refer to installation diagrams included in this manual for additional information. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 1 IP66 • tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Pending Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 2 V-Line® Gen2 V2355 Installation Guide V-Line® Gen2 V2355 Installation Guide When starting any new project, please be sure the following components have been identified. DIMMING COMPONENTS (OPTIONAL) FIXTURE COMPONENTS V-Line® Gen2 V2355 Specifications: LightLink LL-205-10V Watts: V2355A: 14 Watts / Foot (High Output) V2355B: 7 Watts / Foot (Standard Output) Input Voltage: 20-30V DC, 24V DC Nominal Operating Temp: -20°C to 40°C Max Case Temp (Tc): 50°C Humidity: 0 to 95% Non-Condensing LightLink LL-205-TRIAC Dims up to 5 Power Boxes by reading and buffering most any leading and trailing edge incandescent dimmer. 120V AC Input. Both models include onboard dimming buttons with LED bar graph indicator for standalone dimming. MOUNTING BRACKETS CONNECTOR ACCESSORIES Choose 1 of 2 Styles: VLA-13 Adjustable VLA-9 Fixed Aluminum adjustable mounting bracket with stainless steel screws. 180° of On-Center Rotation. Aluminum mounting bracket with stainless steel screws. Mates with dovetail slots on Gen2. PS24V75W-E05P / E05PW Power Box PS28V350W-E10P/E10PH Power Box 120V-277V AC Input Powers up to: 5 Feet of V2355A (High Output) Powers up to: 25 Feet of V2355A (High Output) 10 Feet of V2355B (Standard Output) E05P Model: Indoor E05PW Model: Outdoor Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA Dimming Cable (optional) Indoor 1 foot: 685-01561-1 25 feet: 685-01561-25 Outdoor 1 foot: 685-02026-1 25 feet: 685-02026-25 POWER BOX (REQUIRED) 3 Dims up to 5 Power Boxes using a 0 to 10V Input (sink or source) per IEC 60929:2006 Annex E. 120-277V AC Input. Power Extension Cables (required) (optional) 685-01859-6 1 foot: 685-01670-1 3 foot: 685-01670-3 10 foot: 685-01670-10 6 foot power input cable for hard-wire or connection to power box. Power extension cables with dual waterproof plugs. For plugging between power boxes and/or LightLink dimmers. 50 Feet of V2355B (Standard Output) End-to-End Connector End Plug (optional) (required) E10P Model: 120-240V AC Input E10PH Model: 208-480V AC Input 720-01868 530-01757 Install Indoors Only. Contact us for outdoor. tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Power Input Cables Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Connector allows vertical installation and relamping. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] One end plug must be installed in last fixture of each run to properly seal the fixture. Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 4 V-Line® Gen2 V2355 Installation Guide V-Line® Gen2 V2355 Installation Guide CHOOSING AN INSTALLATION SITE WET LOCATION / OUTDOOR USE When selecting a site for product installation, as with any LED Lighting Product, be sure to keep in mind that at some point the Products may need to be cleaned, repaired, or replaced. Planning ahead for simple product access will assist in reducing headaches down the road. Use Only Wet Location Fixtures For Exterior Applications. Any V-Line® Gen2 Fixture Marked “ I ” Is Indoor Only And Is Not To Be Used For Exterior Applications. TEMPERATURE CONSIDERATIONS V2355A-26CAB Product is rated for an Operating Temperature range of -20 to 40°C with a rated maximum Case Temperature of 50°C. Case Temperature is measured at a test point located in the center of the back side of the Product’s extrusion housing. V2355A-26CAB I Outdoor Installation Considerations: • Product is rated for exterior applications; however it is not rated for submersible applications and should not be mounted in conditions where there is, or is a possibility of, standing water. Installations that may lead to Case Temperatures above 50°C include: • Installing the Product in an area above 40°C ambient temperature. • Operating the Product during daylight hours when installed in direct sunlight in hot climates. • Product should not be installed in extreme locations including, but not limited to, those outside of its temperature/humidity ratings and/or applications where Product is subject to water runoff or downspouts. • When installing in wet or damp locations, it is good practice to seal all fixtures and junction boxes with electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in wiring compartments, cables, or other electrical parts. • Installing the Product in a sealed compartment. • Installing the Product between panes of glass or directly behind a glass window. • Installing the Product in a tight and/or insulated space. Product should not be installed in applications that exhibit a greater-than-average ambient temperature variation over a short period of time. Examples include those instances where the Product is rapidly heated or cooled at a rate that occurs faster than that typically found in nature. Should you have any concerns about your installation, contact us. Product is equipped with i2Systems Active Thermal Management (ATM). In an overheat condition, ATM reduces Product power in order to reduce Case Temperature. However, ATM should not be relied upon as a means of normal operation. Please be sure the Product is operated at or below these specified Operating and Case Temperature levels. Failure to do so will void the warranty. CONNECTION CONSIDERATIONS • When installing, ensure all connector plugs are fully seated. Failure to do so may result in intermittent connection, corrosion, and/or leaking into the main housing. • Any Product connector that is not used is to be capped with End Plug, model: 530-01757. The End Plug is commonly used at the end of each Product Run and/or on every Product used Standalone (not plugged into another Product). CAUTION: Failure to install the End Plug may result in corrosion and failure of the product. Please be sure your product installation complies with the above guidelines. Failure to do so will void the warranty. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 5 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 6 V-Line® Gen2 V2355 Installation Guide V-Line® Gen2 V2355 Installation Guide FIXTURE INSTALLATION FIXTURE INSTALLATION VLA-13 Adjustable VLA-9 Fixed .38" Space between [9mm] fixtures Ø.26" [6mm] End-to-End Plug, model 720-01868 installs through bracket "window". Product Installs to bracket via two dovetail strips. Strips slide freely prior to tightening. Be sure to fully tighten during installation. 1.13" [29mm] .25" [6mm] .84" [21mm] 2.68" [68mm] 1.85" [47mm] Tighten screws to secure fixture .75" [19mm] .25" [6mm] 1.33" [34mm] .83" [21mm] 1.50" [38mm] 1.38" [35mm] 1.50" [38mm] For standalone installation, use two VLA-13s per Product. For continuous runs, use one VLA-13 per Product, with the exception that the last light in the run requires two. Refer to the diagram above. In installations where there is risk of fixtures falling, install a safety strap to both ends of the fixture. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 7 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Use a minimum of two VLA-9 Brackets per Product. Three VLA-9s are recommended for 48" units. In installations where there is risk of fixtures falling, install a safety strap to both ends of the fixture. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 8 V-Line® Gen2 V2355 Installation Guide SYSTEM LAYOUT The diagram below illustrates a basic system installation with dimming installed. For non-dimming installations, the LL-205, dimming cables, and 3rd party dimmer may be omitted. 120-277V AC input PS24V75W-E05P Use E05 Power Box For Short Runs E05P: Indoor E05PW: Outdoor AC input* Install End Plug 530-01757 to last light of each run 685-01859-6 Input Cable PS28V350WE10P / E10PH *E10P: 120-240V AC E10PH: 208-480V AC 685-01859-6 Input Cable 3/8” (.375) gap required between fixtures Install End Plug 530-01757 to last light of each run Patent-pending End-to-End Connector 720-01868 allows vertical installation and relamping. Install End Plug 530-01757 to last light of each run Max Wire Distance (including V-Line Gen2 Luminaire Lengths and All Cables) V2355A (High Output) 50 Feet V2355B (Standard Output) 100 Feet 685-01859-6 Input Cable AC input* Max Fixture Plug Together: V2355A (High Output) 25 Feet V2355B (Standard Output) 50 Feet PS28V350WE10P / E10PH *E10P: 120-240V AC E10PH: 208-480V AC 4 Conductor Cable (optional, supplied by others) to be 12awg minimum Max Distance: 300 Feet to Last Power Box 685-01670-X Extension Cable (Specify Length as: -1, -3, or -10) Use Junction Box (optional, supplied by others) for Remote Runs from Power Box CAUTION: End Plug must be installed to properly seal the fixture. (Optional) 120-277V AC input (Optional) LL-205 Tip on Locating Power Boxes & Dimmers Dimming Cable (optional) For best results, be sure to follow maximum distance and load guidelines as outlined in this installation guide. Power Boxes are typically installed indoors. To install a Power Box outdoors, use PS24V75W-E05PW or contact us for additional Wet Location Power Box recommendations. All Gen2 power and extension cables may be used indoor / outdoor. LL-205-10V / -TRIAC Dims up to 5 Power Boxes Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 9 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] 3rd Party Dimmer TRIAC or 0 to 10V Control Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Use 685-02026-X Dimming Cable for Power Boxes installed outdoors. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 10 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS 100% Intensity, No Dimming with SYNC Option Using PS28V350W-E10P/PH Power Box (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) 15A DC COMMON 480W Industrial-Grade UL-Listed Power Supply AC FEED* 28V DC, 350W MAX LED LOAD DIMMING + 685-01859-6 Input Cable DIMMING - NEUTRAL/L2* (WHT) DIM OUT GRN/YEL Optional 685-01561-25 Dimming Cable DIM IN *AC Source Connections E10P Model: 120-240V AC Input E10PH Model: 208-480V AC Input To next Power Box (see Tip on Synchronizing Power Boxes) V2355 Using PS24V75W-E05P (recommended for short runs) PS24V75W-E05P* 24V DC, 75W MAX HOT (BLK) DC COMMON 100W, UL-Listed Class 2 Power Supply 120-277V AC FEED DIMMING + DIMMING - NEUTRAL (WHT) 685-01859-6 Input Cable GRN/YEL DIM IN Installation Tip: Synchronizing Power Boxes To sync multiple power boxes at power on, use i2Systems Dimming Cable 685-01561-25 or 685-02026-25. Up to 5 may be daisy-chained together. DIM OUT Optional Dimming Cable* *When installing the Power Box outdoors: - Use PS24V75W-E05PW Power Box - Use 685-02026-25 Dimming Cable Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 11 V2355 To next Power Box (see Tip on Synchronizing Power Boxes) tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 12 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS Wall Mount, Push-Button Dimming Using PS28V350W-E10P/PH Power Box (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) 15A 480W Industrial-Grade UL-Listed Power Supply AC FEED* 28V DC, 350W MAX LED LOAD DC COMMON DIMMING + 685-01859-6 Input Cable DIMMING - NEUTRAL/L2* (WHT) DIM OUT To next Power Box GRN/YEL DIM IN *AC Source Connections E10P Model: 120-240V AC Input E10PH Model: 208-480V AC Input V2355 685-01561-25 Dimming Cable HOT (BLK) Operation: LL-205* 120V-277V AC FEED LED bar graph indicator shows selected dim levels Non-Switched Circuit Dim Up and Down buttons for Manual Dimming 13 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. Double-tap for 100% intensity. To Dim Down, press and hold the left Dim button. Single-tap to turn lights off. The LED bar graph will show selected dim levels. One LL-205 dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205. Refer to the LL-205 Installation Guide for additional details and technical specifications. WHT GRN/YEL NEUTRAL (WHT) Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA *The following LL-205 Models may be used for push-button dimming: • LL-205-S • LL-205-10V • LL-205-TRIAC To Dim Up, press and hold the right Dim button. Single-tap to return to previous intensity. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 14 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS Wall Mount, Push-Button Dimming Using PS24V75W-E05P Power Box (recommended for short runs) PS24V75W-E05P* 24V DC HOT (BLK) DC COMMON 100W, UL-Listed Class 2 Power Supply 120-277V AC FEED DIMMING + DIMMING - NEUTRAL (WHT) 685-01859-6 Input Cable GRN/YEL DIM IN DIM OUT **When installing the Power Box outdoors: - Use PS24V75W-E05PW Power Box - Use 685-02026-25 Dimming Cable V2355 To next Power Box Dimming Cable* HOT (BLK) Operation: LL-205** 120V-277V AC FEED Non-Switched Circuit To Dim Up, press and hold the right Dim button. Single-tap to return to previous intensity. LED bar graph indicator shows selected dim levels Dim Up and Down buttons for Manual Dimming **The following LL-205 Models may be used for push-button dimming: • LL-205-S • LL-205-10V • LL-205-TRIAC Double-tap for 100% intensity. To Dim Down, press and hold the left Dim button. Single-tap to turn lights off. The LED bar graph will show selected dim levels. One LL-205 dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205. Refer to the LL-205 Installation Guide for additional details and technical specifications. WHT GRN/YEL NEUTRAL (WHT) Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 15 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 16 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS O to 10V Dimming, Sink or Source Using PS28V350W-E10P/PH Power Box (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) 28V DC, 350W MAX LED LOAD 15A DC COMMON 480W Industrial-Grade UL-Listed Power Supply AC FEED* DIMMING + 685-01859-6 Input Cable DIMMING - NEUTRAL/L2* (WHT) DIM OUT To next Power Box GRN/YEL DIM IN *AC Source Connections E10P Model: 120-240V AC Input E10PH Model: 208-480V AC Input V2355 685-01561-25 Dimming Cable HOT (BLK) 3rd Party 0 to 10V Dimmer Operation: LL-205-10V LL-205-10V reads 0 to 10V levels and translates them to i2Systems dimming protocol. 120V-277V AC FEED LED bar graph indicator shows selected dim levels Non-Switched Circuit Dim Up and Down buttons for Manual Dimming Per IEC 60929:2006 Annex E:Less than 1V = OffGreater than 9V = 100% Intensity Between 1V and 9V, intensity will be adjusted on the Gen2 fixture V2355 from 1% to 100%. The LED bar graph will display Dim levels based on the 0 to 10V Levels. To manually override the incoming 0 to 10V signal, press either button on the LL-205-10V. Manual operation is described on page 14. 10V, SINK / SOURCE One LL-205-10V dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205-10V. VIO BRN WHT Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 17 Refer to the LL-205 Installation Guide for additional details and technical specifications. GRN/YEL NEUTRAL (WHT) tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 18 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS O to 10V Dimming, Sink or Source Using PS24V75W-E05P Power Box (recommended for short runs) PS24V75W-E05P* 24V DC HOT (BLK) DC COMMON 100W, UL-Listed Class 2 Power Supply 120-277V AC FEED DIMMING + DIMMING - NEUTRAL (WHT) 685-01859-6 Input Cable GRN/YEL DIM IN DIM OUT *When installing the Power Box outdoors: - Use PS24V75W-E05PW Power Box - Use 685-02026-25 Dimming Cable V2355 To next Power Box Dimming Cable* HOT (BLK) 3rd Party 0 to 10V Dimmer Operation: LL-205-10V 120V-277V AC FEED LED bar graph indicator shows selected dim levels Non-Switched Circuit Dim Up and Down buttons for Manual Dimming LL-205-10V reads 0 to 10V levels and translates them to i2Systems dimming protocol. Per IEC 60929:2006 Annex E: Less than 1V = Off Greater than 9V = 100% Intensity Between 1V and 9V, intensity will be adjusted on the Gen2 fixture V2355 from 1% to 100%. The LED bar graph will display Dim levels based on the 0 to 10V Levels. 10V, SINK / SOURCE To manually override the incoming 0 to 10V signal, press either button on the LL-205-10V. Manual operation is described on page 14. VIO BRN One LL-205-10V dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 68502026-X to daisy-chain Power Boxes to a single LL-205-10V. WHT GRN/YEL NEUTRAL (WHT) Refer to the LL-205 Installation Guide for additional details and technical specifications. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 19 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 20 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS Leading / Trailing Edge TRIAC Dimming Using PS28V350W-E10P/PH Power Box (recommended for longer runs) PS28V350W-E10P/PH HOT/L1* (BLK) 28V DC, 350W MAX LED LOAD 15A DC COMMON 480W Industrial-Grade UL-Listed Power Supply AC FEED* DIMMING + 685-01859-6 Input Cable DIMMING - NEUTRAL/L2* (WHT) DIM OUT To next Power Box GRN/YEL DIM IN *AC Source Connections E10P Model: 120-240V AC Input E10PH Model: 208-480V AC Input V2355 685-01561-25 Dimming Cable HOT (BLK) Dimmer In 3rd Party TRIAC Dimmer Operation: LL-205-TRIAC 120V AC 60HZ FEED LL-205-TRIAC reads the conventional TRIAC dimmer levels and translates them to i2Systems dimming protocol. Non-Switched Circuit Input may include both Leading and Trailing Edge 120V AC dimmers. Trailing Edge dimmers (those specified as Low Voltage Dimmers) yield best performance. Dim Up and Down buttons for Manual Dimming Neutral** The LED bar graph will display Dim levels based on the interpreted TRIAC levels (results may vary). Dimmer Out RED WHT RED/WHT NEUTRAL (WHT) GRN/YEL Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 21 The TRIAC is not loaded, and in most cases a minimum load will not be required. LED bar graph indicator shows selected dim levels tel +1.860.567.0708 fax +1.860.567.2501 [email protected] **Optional. Only connect AC Neutral to dimmers with a Neutral wire hookup. Refer to the dimmer manual and/or manufacturer for sample wiring diagrams as wiring varies depending on dimmer type and hookup. Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Most, but not all, TRIAC dimmers will work and some will yield better results than others. Contact us to preapprove the dimmer you've selected for your project. One LL-205-TRIAC dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205-TRIAC. Refer to the LL-205 Installation Guide for additional details and technical specifications. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 22 V-Line® Gen2 V2355 Installation Guide TYPICAL INSTALLATIONS Leading / Trailing Edge TRIAC Dimming Using PS24V75W-E05P Power Box (recommended for short runs) PS24V75W-E05P* 24V DC HOT (BLK) DC COMMON 100W, UL-Listed Class 2 Power Supply 120-277V AC FEED DIMMING + 685-01859-6 Input Cable DIMMING - NEUTRAL (WHT) GRN/YEL DIM IN DIM OUT *When installing the Power Box outdoors: - Use PS24V75W-E05PW Power Box - Use 685-02026-25 Dimming Cable V2355 To next Power Box Dimming Cable* HOT (BLK) Dimmer In 3rd Party TRIAC Dimmer Operation: LL-205-TRIAC 120V AC 60HZ FEED LL-205-TRIAC reads the conventional TRIAC dimmer levels and translates them to i2Systems dimming protocol. Non-Switched Circuit Input may include both Leading and Trailing Edge 120V AC dimmers. Trailing Edge dimmers (those specified as Low Voltage Dimmers) yield best performance. Dim Up and Down buttons for Manual Dimming Neutral** The LED bar graph will display Dim levels based on the interpreted TRIAC levels (results may vary). Dimmer Out RED WHT RED/WHT NEUTRAL (WHT) GRN/YEL Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 23 The TRIAC is not loaded, and in most cases a minimum load will not be required. LED bar graph indicator shows selected dim levels tel +1.860.567.0708 fax +1.860.567.2501 [email protected] **Optional. Only connect AC Neutral to dimmers with a Neutral wire hookup. Refer to the dimmer manual and/or manufacturer for sample wiring diagrams as wiring varies depending on dimmer type and hookup. Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Most, but not all, TRIAC dimmers will work and some will yield better results than others. Contact us to preapprove the dimmer you've selected for your project. One LL-205-TRIAC dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205-TRIAC. Refer to the LL-205 Installation Guide for additional details and technical specifications. Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 24 V-Line® Gen2 V2355 Installation Guide V-Line® Gen2 V2355 Installation Guide FREQUENTLY ASKED QUESTIONS LIMITED WARRANTY Basic Installation 1.1 Limited Warranty. Products are warranted to be free from defects in material and workmanship and to conform substantially to Seller’s then-current (as of the date of Product shipment) user documentation and specifications for a period of three (3) years from the date of invoice (the “Warranty Period”), provided the Products are used under those operating conditions (including electrical values and environmental conditions) described in Seller’s then-current user documentation and specifications for such Products. Seller shall not be liable under the foregoing warranty if Buyer fails to provide Seller with notice of the alleged defect during the Warranty Period. Q: Can I connect the Gen2 directly to line voltage? A: No. Connecting the Gen2 directly to line voltage or any voltage higher than 30V DC will damage the fixture and void the warranty. Use an i2Systems Power Box to convert line voltage to low voltage. Q: A: I see the Gen2 is rated from 20-30V DC. Will the intensity vary over the voltage range? No. The light output will remain constant over the full range. Based on the Gen2’s constant power design, as the voltage drops, the current will increase proportionally (conversely, it will go down as the voltage rises), adding additional current load in the wiring and on the Power Box. Q: Can I load the Power Box to the full wattage specified (i.e. 75W or 350W)? A: Yes. The power supplies installed in i2Systems Power Boxes are derated (i.e. a 75W Power Box uses a 100W Power Supply). Refer to the Power Box Datasheet for additional details. Q: A: Can I use a 3rd party low voltage power supply? While it is possible to use a 3rd party 24V DC power source, we highly discourage this and doing so may void the Gen2's warranty. Not all power supplies exhibit the same characteristics and there is the possibility of the power supply being incompatible or causing damage to the Gen2 fixture. Dimming-Related Q: A: For installations without dimming, what do I do with the orange and violet wires on the Gen2? The orange and violet wires on the Gen2 are for isolated dimming control. These wires are optically isolated to the Gen2 power and may be cut and capped using best industry practices. Alternatively, tie all orange wires to orange wires and violet wires to violet wires to synchronize light turn-on when power is applied. Refer to the diagram on page 11. Q: Is the LightLink LL-205 limited to dimming 5 Power Boxes? A: No. The LightLink LL-205 is capable of dimming more than 5 Power Boxes. Please refer to the LL-205 Installation Guide for additional details. Q: When using the LightLink LL-205 Dimming Module, do I need a 3rd Party Dimmer? A: No. The LL-205 is often used as a standalone dimmer. This feature is useful for simple installations and/or troubleshooting dimming installations where the LightLink is able to override the incoming dimming signal to help pinpoint the problem. Q: Can I mix and match i2Systems Product series on the same LightLink dimmer? A: Yes. However, contact us prior to doing so, as results may vary, depending on the Product. 1.2 Remedies. In the event a Product does not comply with the foregoing express warranty, Buyer may notify Seller within the Warranty Period and if so notified Seller will, at Seller’s option: (a) provide a replacement for such Product or defective component or part thereof that has caused the warranty claim (such Product or defective component or part thereof that has caused the warranty claim, the “Warranty Item”); or (b) refund to Seller the lesser of (1) the amount Seller paid for the Warranty Item, and (2) Seller’s cost to replace the Warranty Item, in each case as determined by Seller in its sole and absolute discretion following receipt and inspection by Seller of the Warranty Item. For the avoidance of doubt, “provided a replacement for such Product or defective component or part thereof” expressly does not include any removal or reinstallation costs or expenses, including without limitation labor costs or expenses. All exchanged Warranty Items shall become the property of Seller. Seller may use either new or remanufactured, reconditioned or refurbished components or parts (if in like-new condition), or functionally equivalent components or parts, in the furnishing of replacement(s) for any Warranty Item. Seller’s warranty flows only to Buyer of the products. If the Seller chooses to replace the Product and is not able to do so because it has been discontinued or is not available, the Seller may replace it with a comparable product. 1.3 Limitations. The foregoing warranty is limited, and does not extend to, and Seller shall incur no liability for: (a) lumen maintenance of the Products; (b) color shift of light output of the Products; (c) degradation or discoloration of the Product housing(s); (d) mechanical or cosmetic deterioration of the Products associated with normal wear and tear. For clarity and without limiting the generality of the foregoing, the foregoing warranty does not apply if a Product’s light module continuously generates light at any intensity, regardless of whether such intensity has decreased since the date of first use of such Product [(viz., warranty coverage only applies in the event that such light module generates no light or generates light intermittently)]. This limited warranty only applies when the product has been properly wired and installed and operated within the electrical values, operating range and environmental conditions provided in the Specifications. This warranty does not apply to damage or failure to perform arising as a result of any Acts of God or from any abuse, misuse, abnormal use or use in violation of any applicable standard, code, or instructions for use including those contained in the latest National Electrical Code, the Standards for Safety of Underwriters Laboratory, Inc., the Standards for the American National Standards Institute or, in Canada, the Canadian Standards Association. This Warranty shall become void in the event any repairs or alternations not duly authorized by the Seller in writing are made to the Product by any person. Buyer shall convey with each Product distributed to end users this LIMITED WARRANTY, and if Seller determines that the appropriate remedy for a defective product is refund of Buyer’s purchase price, Buyer shall refund to the end user (or arrange for the refund to the end user of) the full purchase price paid by the end user for such defective Product. With respect to Products sold to the Buyer by Seller but not bearing the Seller’s name or sub-brand name, SELLER MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, but will make available to the Buyer upon request but only to the extent permitted by law and relevant contracts, the warranties of the manufacturer of the relevant product. 1.4 Exclusions; Buyer Indemnification. The foregoing warranty shall be void with respect to defective conditions or non-conformities of the Products resulting from: (a) modifications of Products not authorized by Seller; (b) misuse, neglect, accident or abuse, improper wiring, repairing, splicing, alteration, installation, storage or maintenance; (c) use in a manner not in accordance with Seller’s published operating specifications or instructions for the applicable Products; (d) Product defects caused by Buyer’s combination of the Products with equipment provided or manufactured by third party vendors (unless Seller is advised, in writing, of such proposed combination and Seller thereafter consents in writing to such combination); (e) breach by Buyer or its employees, partners to whom Buyer sold Product, contractors, representatives, agents or affiliates, (collectively, “Buyer Parties”) of any obligation herein; or (f) negligent use, application, installation or implementation of Product by any of the Buyer Parties. Buyer shall indemnify, defend and hold harmless Seller and its officers, directors, agents, employees, affiliates, representatives, successors, and assigns from and against all losses, liabilities, costs, and expenses (including, without limitation, attorneys’ fees) arising out of out of or in connection with claims by third parties for any loss, damage, or injury (including death) caused by or alleged to be caused by the circumstances described in this Section 5.4. Buyer shall not join, settle or otherwise attempt to affect or dispose of any such claim without Seller’s written consent. 1.5 DISCLAIMER. THE EXPRESS WARRANTIES IN THIS SECTION ARE THE ONLY WARRANTIES GRANTED BY SELLER AND THE REMEDIES IN THIS SECTION 5 ARE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF SUCH WARRANTIES. EXCEPT AS EXPRESSLY PROVIDED IN THIS SECTION 1, SELLER MAKES NO OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, AND SELLER EXPRESSLY DISCLAIMS ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF QUALITY, CONDITION, TITLE, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. No agent, employee, or representative of Seller has any authority to bind Seller to any affirmation, representation or warranty concerning goods sold by Seller and unless an affirmation, representation or warranty is specifically included herein or in Seller’s sales acknowledgement, it does not form a part of the basis of any bargain between Seller and Buyer and shall not be enforceable by Buyer. For i2Systems complete Terms & Conditions of Sale, please visit our website at www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA 25 tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com Integrated Illumination Systems, Inc. 355 Bantam Lake Road Morris, CT 06763 USA tel +1.860.567.0708 fax +1.860.567.2501 [email protected] Product information is subject to change without notice. All brand names and product names are trademarks of i2Systems. © 2012 i2Systems. All Rights Reserved. www.i2systems.com 090-01965B 26 tel +1.860.567.0708 www.i2systems.com