Transcript
V-Line® Gen2 V2355
Installation Guide
V-Line® Gen2 V2355 Installation Guide
INTRODUCTION
The following installation guide has been assembled to assist in planning, installing and
wiring of the V-Line® Gen2 V2355 Fixture. Please read the following instructions carefully prior
to installing the fixtures. Should you have any questions or require project consultation, please
contact us prior to specifying or installing any i2Systems Product.
Available Resources In Addition To This Guide Include:
Thank you for your
purchase of i2Systems
V-Line® Gen2 LED fixture!
– V-Line® Gen2 V2355 Datasheet*
– Power Box PS24V75W-E05P / E05PW Datasheet*
– V-Line® Gen2 V2355 Instruction Sheet
(included with every fixture shipped)
– Power Box PS28V350W-E10P / E10PH Datasheet*
– i2Systems Technical Support (9am - 5pm EST)
+1.860.567.0708 or [email protected]
– LightLink LL-205 Installation Guide*
*Available at www.i2systems.com
Questions? We are here to help.
Call us directly at +1.860.567.0708.
ELECTRICAL WARNINGS
FIXTURE MAINTENANCE
•
• All Products must be installed by a qualified
electrician in accordance with all national and local
electrical and construction codes and regulations.
• Do not attempt to install or use a Product until you
have read and understand the installation
instructions and safety labels.
Clean the fixture with mild soap and water only.
Ensure that any cleaning products that you use on
the optic do not contain plasticizers as they can
damage the optic.
• Do not clean the fixture with high pressure washers
or pointed objects as they can damage the Product
and cause potential breaches of seals.
• Products have risk of shock and no user-serviceable
parts. Do not attempt to disassemble the light fixture
in any way.
• Do not submerse the Product when cleaning, or
allow to sit in standing water.
• Never exceed the maximum voltage rating of
the Product.
CERTIFICATIONS
• When installing or servicing the Product, be sure
to disconnect the power prior to beginning work.
Do not make live connections, also known as
hot-swapping. Ensure that power to the Product
is off before connecting or disconnecting
individual units.
•
Maximum plug together for Standard Output (V2355B)
is 50 feet of fixtures. Maximum plug together for High Output (V2355A) is 25 feet of fixtures. Refer to installation diagrams included in this manual for additional information.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
1
IP66
•
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Pending
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
2
V-Line® Gen2 V2355 Installation Guide
V-Line® Gen2 V2355 Installation Guide
When starting any new project, please be sure the following components have been identified.
DIMMING COMPONENTS (OPTIONAL)
FIXTURE COMPONENTS
V-Line® Gen2 V2355 Specifications:
LightLink LL-205-10V
Watts:
V2355A: 14 Watts / Foot (High Output)
V2355B: 7 Watts / Foot (Standard Output)
Input Voltage:
20-30V DC, 24V DC Nominal
Operating Temp:
-20°C to 40°C
Max Case Temp (Tc):
50°C
Humidity:
0 to 95% Non-Condensing
LightLink LL-205-TRIAC
Dims up to 5 Power Boxes by reading and buffering
most any leading and trailing edge incandescent
dimmer. 120V AC Input.
Both models include onboard dimming buttons with
LED bar graph indicator for standalone dimming.
MOUNTING BRACKETS
CONNECTOR ACCESSORIES
Choose 1 of 2 Styles:
VLA-13 Adjustable
VLA-9 Fixed
Aluminum adjustable
mounting bracket with
stainless steel screws.
180° of On-Center
Rotation.
Aluminum mounting
bracket with stainless
steel screws. Mates with
dovetail slots on Gen2.
PS24V75W-E05P / E05PW
Power Box
PS28V350W-E10P/E10PH
Power Box
120V-277V AC Input
Powers up to:
5 Feet of V2355A
(High Output)
Powers up to:
25 Feet of V2355A
(High Output)
10 Feet of V2355B
(Standard Output)
E05P Model: Indoor
E05PW Model: Outdoor
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
Dimming Cable (optional)
Indoor
1 foot: 685-01561-1
25 feet: 685-01561-25
Outdoor
1 foot: 685-02026-1
25 feet: 685-02026-25
POWER BOX (REQUIRED)
3
Dims up to 5 Power Boxes using a 0 to 10V Input
(sink or source) per IEC 60929:2006 Annex E.
120-277V AC Input.
Power Extension Cables
(required)
(optional)
685-01859-6
1 foot: 685-01670-1
3 foot: 685-01670-3
10 foot: 685-01670-10
6 foot power input cable
for hard-wire or connection
to power box.
Power extension cables with
dual waterproof plugs.
For plugging between power
boxes and/or LightLink dimmers.
50 Feet of V2355B
(Standard Output)
End-to-End Connector
End Plug
(optional)
(required)
E10P Model: 120-240V AC Input
E10PH Model: 208-480V AC Input
720-01868
530-01757
Install Indoors Only. Contact us for outdoor.
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Power Input Cables
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Connector allows vertical
installation and relamping.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
One end plug must be installed
in last fixture of each run to
properly seal the fixture.
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
4
V-Line® Gen2 V2355 Installation Guide
V-Line® Gen2 V2355 Installation Guide
CHOOSING AN INSTALLATION SITE
WET LOCATION / OUTDOOR USE
When selecting a site for product installation, as with any LED Lighting Product, be sure to keep in mind that at
some point the Products may need to be cleaned, repaired, or replaced. Planning ahead for simple product access
will assist in reducing headaches down the road.
Use Only Wet Location Fixtures For Exterior Applications. Any V-Line® Gen2 Fixture Marked “ I ” Is
Indoor Only And Is Not To Be Used For Exterior Applications.
TEMPERATURE CONSIDERATIONS
V2355A-26CAB
Product is rated for an Operating Temperature range of -20 to 40°C with a rated maximum Case Temperature
of 50°C. Case Temperature is measured at a test point located in the center of the back side of the Product’s
extrusion housing.
V2355A-26CAB I
Outdoor Installation Considerations:
• Product is rated for exterior applications; however it is not rated for submersible applications and should
not be mounted in conditions where there is, or is a possibility of, standing water.
Installations that may lead to Case Temperatures above 50°C include:
• Installing the Product in an area above 40°C ambient temperature.
• Operating the Product during daylight hours when installed in direct sunlight in hot climates.
• Product should not be installed in extreme locations including, but not limited to, those outside of its
temperature/humidity ratings and/or applications where Product is subject to water runoff or downspouts. • When installing in wet or damp locations, it is good practice to seal all fixtures and junction boxes with
electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in wiring
compartments, cables, or other electrical parts.
• Installing the Product in a sealed compartment.
• Installing the Product between panes of glass or directly behind a glass window.
• Installing the Product in a tight and/or insulated space.
Product should not be installed in applications that exhibit a greater-than-average ambient temperature
variation over a short period of time. Examples include those instances where the Product is rapidly heated or
cooled at a rate that occurs faster than that typically found in nature. Should you have any concerns about your
installation, contact us.
Product is equipped with i2Systems Active Thermal Management (ATM). In an overheat condition, ATM reduces
Product power in order to reduce Case Temperature. However, ATM should not be relied upon as a means of
normal operation.
Please be sure the Product is operated at or below these specified Operating and Case Temperature levels.
Failure to do so will void the warranty.
CONNECTION CONSIDERATIONS
• When installing, ensure all connector plugs are fully seated. Failure to do so may result in intermittent
connection, corrosion, and/or leaking into the main housing.
• Any Product connector that is not used is to be capped with End Plug, model: 530-01757. The End Plug is
commonly used at the end of each Product Run and/or on every Product used Standalone (not plugged into
another Product). CAUTION: Failure to install the End Plug may result in corrosion and failure of the product.
Please be sure your product installation complies with the above guidelines. Failure to do so will void the warranty.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
5
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
6
V-Line® Gen2 V2355 Installation Guide
V-Line® Gen2 V2355 Installation Guide
FIXTURE INSTALLATION
FIXTURE INSTALLATION
VLA-13 Adjustable
VLA-9 Fixed
.38" Space between
[9mm] fixtures
Ø.26"
[6mm]
End-to-End Plug, model
720-01868 installs through
bracket "window".
Product Installs to bracket via
two dovetail strips. Strips slide
freely prior to tightening. Be
sure to fully tighten during
installation.
1.13"
[29mm]
.25"
[6mm]
.84"
[21mm]
2.68"
[68mm]
1.85"
[47mm]
Tighten screws
to secure fixture
.75"
[19mm]
.25"
[6mm]
1.33"
[34mm]
.83"
[21mm]
1.50"
[38mm]
1.38"
[35mm]
1.50"
[38mm]
For standalone installation, use two VLA-13s per Product. For continuous runs, use one VLA-13 per Product, with the exception that the
last light in the run requires two. Refer to the diagram above.
In installations where there is risk of fixtures falling, install a safety strap to both ends of the fixture.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
7
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Use a minimum of two VLA-9 Brackets per Product. Three VLA-9s are recommended for 48" units.
In installations where there is risk of fixtures falling, install a safety strap to both ends of the fixture.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
8
V-Line® Gen2 V2355 Installation Guide
SYSTEM LAYOUT
The diagram below illustrates a basic system installation with dimming installed. For non-dimming
installations, the LL-205, dimming cables, and 3rd party dimmer may be omitted.
120-277V
AC input
PS24V75W-E05P
Use E05 Power Box
For Short Runs
E05P: Indoor
E05PW: Outdoor
AC input*
Install End Plug
530-01757 to last
light of each run
685-01859-6
Input Cable
PS28V350WE10P / E10PH
*E10P: 120-240V AC
E10PH: 208-480V AC
685-01859-6
Input Cable
3/8” (.375) gap required
between fixtures
Install End Plug
530-01757 to last
light of each run
Patent-pending End-to-End
Connector 720-01868 allows
vertical installation and relamping.
Install End Plug
530-01757 to last
light of each run
Max Wire Distance
(including V-Line Gen2 Luminaire
Lengths and All Cables)
V2355A (High Output) 50 Feet
V2355B (Standard Output) 100 Feet
685-01859-6 Input Cable
AC input*
Max Fixture Plug Together:
V2355A (High Output) 25 Feet
V2355B (Standard Output) 50 Feet
PS28V350WE10P / E10PH
*E10P: 120-240V AC
E10PH: 208-480V AC
4 Conductor Cable
(optional, supplied by others)
to be 12awg minimum
Max Distance:
300 Feet to
Last Power Box
685-01670-X
Extension Cable
(Specify Length as: -1, -3, or -10)
Use Junction Box
(optional, supplied by others) for
Remote Runs from Power Box
CAUTION: End Plug must be installed
to properly seal the fixture.
(Optional)
120-277V
AC input
(Optional)
LL-205
Tip on Locating Power Boxes & Dimmers
Dimming Cable
(optional)
For best results, be sure to follow maximum distance and load
guidelines as outlined in this installation guide.
Power Boxes are typically installed indoors. To install a Power Box
outdoors, use PS24V75W-E05PW or contact us for additional Wet
Location Power Box recommendations.
All Gen2 power and extension cables may be used indoor / outdoor.
LL-205-10V / -TRIAC
Dims up to 5 Power Boxes
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
9
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
3rd Party Dimmer
TRIAC or 0 to 10V Control
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Use 685-02026-X Dimming Cable for Power Boxes installed outdoors.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
10
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
100% Intensity, No Dimming with SYNC Option
Using PS28V350W-E10P/PH Power Box (recommended for longer runs)
PS28V350W-E10P/PH
HOT/L1*
(BLK)
15A
DC COMMON
480W Industrial-Grade
UL-Listed Power Supply
AC FEED*
28V DC, 350W MAX LED LOAD
DIMMING +
685-01859-6
Input Cable
DIMMING -
NEUTRAL/L2*
(WHT)
DIM OUT
GRN/YEL
Optional
685-01561-25
Dimming
Cable
DIM IN
*AC Source Connections
E10P Model: 120-240V AC Input
E10PH Model: 208-480V AC Input
To next Power Box
(see Tip on Synchronizing Power Boxes)
V2355
Using PS24V75W-E05P (recommended for short runs)
PS24V75W-E05P*
24V DC, 75W MAX
HOT (BLK)
DC COMMON
100W, UL-Listed Class 2
Power Supply
120-277V AC FEED
DIMMING +
DIMMING -
NEUTRAL (WHT)
685-01859-6
Input Cable
GRN/YEL
DIM IN
Installation Tip: Synchronizing Power Boxes
To sync multiple power boxes at power on, use i2Systems Dimming
Cable 685-01561-25 or 685-02026-25. Up to 5 may be daisy-chained
together.
DIM OUT
Optional
Dimming Cable*
*When installing the Power Box outdoors:
- Use PS24V75W-E05PW Power Box
- Use 685-02026-25 Dimming Cable
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
11
V2355
To next Power Box
(see Tip on Synchronizing Power Boxes)
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
12
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
Wall Mount, Push-Button Dimming
Using PS28V350W-E10P/PH Power Box (recommended for longer runs)
PS28V350W-E10P/PH
HOT/L1*
(BLK)
15A
480W Industrial-Grade
UL-Listed Power Supply
AC FEED*
28V DC, 350W MAX LED LOAD
DC COMMON
DIMMING +
685-01859-6
Input Cable
DIMMING -
NEUTRAL/L2*
(WHT)
DIM OUT
To next
Power Box
GRN/YEL
DIM IN
*AC Source Connections
E10P Model: 120-240V AC Input
E10PH Model: 208-480V AC Input
V2355
685-01561-25
Dimming Cable
HOT (BLK)
Operation:
LL-205*
120V-277V
AC FEED
LED bar graph indicator
shows selected dim levels
Non-Switched
Circuit
Dim Up and Down buttons
for Manual Dimming
13
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
Double-tap for 100% intensity. To Dim Down, press and hold the left Dim
button. Single-tap to turn lights off.
The LED bar graph will show selected dim levels.
One LL-205 dims up to 5 Power Boxes. Use i2Systems Dimming Cable
685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205.
Refer to the LL-205 Installation Guide for additional details and technical specifications.
WHT
GRN/YEL
NEUTRAL (WHT)
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
*The following LL-205 Models
may be used for push-button dimming:
• LL-205-S
• LL-205-10V
• LL-205-TRIAC
To Dim Up, press and hold the right Dim button. Single-tap to return to previous intensity.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
14
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
Wall Mount, Push-Button Dimming
Using PS24V75W-E05P Power Box (recommended for short runs)
PS24V75W-E05P*
24V DC
HOT (BLK)
DC COMMON
100W, UL-Listed Class 2
Power Supply
120-277V AC FEED
DIMMING +
DIMMING -
NEUTRAL (WHT)
685-01859-6
Input Cable
GRN/YEL
DIM IN
DIM OUT
**When installing the Power Box outdoors:
- Use PS24V75W-E05PW Power Box
- Use 685-02026-25 Dimming Cable
V2355
To next
Power Box
Dimming Cable*
HOT (BLK)
Operation:
LL-205**
120V-277V
AC FEED
Non-Switched
Circuit
To Dim Up, press and hold the right Dim button. Single-tap to return to previous intensity.
LED bar graph indicator
shows selected dim levels
Dim Up and Down buttons
for Manual Dimming
**The following LL-205 Models
may be used for push-button dimming:
• LL-205-S
• LL-205-10V
• LL-205-TRIAC
Double-tap for 100% intensity. To Dim Down, press and hold the left Dim
button. Single-tap to turn lights off.
The LED bar graph will show selected dim levels.
One LL-205 dims up to 5 Power Boxes. Use i2Systems Dimming Cable
685-01561-X or 685-02026-X to daisy-chain Power Boxes to a single LL-205.
Refer to the LL-205 Installation Guide for additional details and technical specifications.
WHT
GRN/YEL
NEUTRAL (WHT)
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
15
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
16
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
O to 10V Dimming, Sink or Source
Using PS28V350W-E10P/PH Power Box (recommended for longer runs)
PS28V350W-E10P/PH
HOT/L1*
(BLK)
28V DC, 350W MAX LED LOAD
15A
DC COMMON
480W Industrial-Grade
UL-Listed Power Supply
AC FEED*
DIMMING +
685-01859-6
Input Cable
DIMMING -
NEUTRAL/L2*
(WHT)
DIM OUT
To next
Power Box
GRN/YEL
DIM IN
*AC Source Connections
E10P Model: 120-240V AC Input
E10PH Model: 208-480V AC Input
V2355
685-01561-25
Dimming Cable
HOT (BLK)
3rd Party
0 to 10V Dimmer
Operation:
LL-205-10V
LL-205-10V reads 0 to 10V levels and translates them to i2Systems dimming protocol.
120V-277V
AC FEED
LED bar graph indicator
shows selected dim levels
Non-Switched
Circuit
Dim Up and Down buttons
for Manual Dimming
Per IEC 60929:2006 Annex E:Less than 1V = OffGreater than 9V = 100% Intensity
Between 1V and 9V, intensity will be adjusted on the Gen2 fixture V2355 from 1% to 100%.
The LED bar graph will display Dim levels based on the 0 to 10V Levels.
To manually override the incoming 0 to 10V signal, press either button on the LL-205-10V.
Manual operation is described on page 14.
10V, SINK / SOURCE
One LL-205-10V dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or
685-02026-X to daisy-chain Power Boxes to a single LL-205-10V.
VIO
BRN
WHT
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
17
Refer to the LL-205 Installation Guide for additional details and technical specifications.
GRN/YEL
NEUTRAL (WHT)
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
18
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
O to 10V Dimming, Sink or Source
Using PS24V75W-E05P Power Box (recommended for short runs)
PS24V75W-E05P*
24V DC
HOT (BLK)
DC COMMON
100W, UL-Listed Class 2
Power Supply
120-277V AC FEED
DIMMING +
DIMMING -
NEUTRAL (WHT)
685-01859-6
Input Cable
GRN/YEL
DIM IN
DIM OUT
*When installing the Power Box outdoors:
- Use PS24V75W-E05PW Power Box
- Use 685-02026-25 Dimming Cable
V2355
To next
Power Box
Dimming Cable*
HOT (BLK)
3rd Party
0 to 10V Dimmer
Operation:
LL-205-10V
120V-277V
AC FEED
LED bar graph indicator
shows selected dim levels
Non-Switched
Circuit
Dim Up and Down buttons
for Manual Dimming
LL-205-10V reads 0 to 10V levels and translates them to i2Systems dimming protocol.
Per IEC 60929:2006 Annex E:
Less than 1V = Off
Greater than 9V = 100% Intensity
Between 1V and 9V, intensity will be adjusted on the Gen2 fixture V2355 from 1% to 100%.
The LED bar graph will display Dim levels based on the 0 to 10V Levels.
10V, SINK / SOURCE
To manually override the incoming 0 to 10V signal, press either button on the LL-205-10V.
Manual operation is described on page 14.
VIO
BRN
One LL-205-10V dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 68502026-X to daisy-chain Power Boxes to a single LL-205-10V.
WHT
GRN/YEL
NEUTRAL (WHT)
Refer to the LL-205 Installation Guide for additional details and technical specifications.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
19
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
20
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
Leading / Trailing Edge TRIAC Dimming
Using PS28V350W-E10P/PH Power Box (recommended for longer runs)
PS28V350W-E10P/PH
HOT/L1*
(BLK)
28V DC, 350W MAX LED LOAD
15A
DC COMMON
480W Industrial-Grade
UL-Listed Power Supply
AC FEED*
DIMMING +
685-01859-6
Input Cable
DIMMING -
NEUTRAL/L2*
(WHT)
DIM OUT
To next
Power Box
GRN/YEL
DIM IN
*AC Source Connections
E10P Model: 120-240V AC Input
E10PH Model: 208-480V AC Input
V2355
685-01561-25
Dimming Cable
HOT (BLK)
Dimmer In
3rd Party
TRIAC Dimmer
Operation:
LL-205-TRIAC
120V AC
60HZ FEED
LL-205-TRIAC reads the conventional TRIAC dimmer levels and translates them to i2Systems dimming protocol.
Non-Switched
Circuit
Input may include both Leading and Trailing Edge 120V AC dimmers. Trailing Edge dimmers (those specified as
Low Voltage Dimmers) yield best performance.
Dim Up and Down buttons
for Manual Dimming
Neutral**
The LED bar graph will display Dim levels based on the interpreted TRIAC levels (results may vary).
Dimmer
Out
RED
WHT
RED/WHT
NEUTRAL (WHT)
GRN/YEL
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
21
The TRIAC is not loaded, and in most cases a minimum load will not be required.
LED bar graph indicator
shows selected dim levels
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
**Optional.
Only connect AC Neutral to dimmers with a
Neutral wire hookup. Refer to the dimmer
manual and/or manufacturer for sample
wiring diagrams as wiring varies depending
on dimmer type and hookup.
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Most, but not all, TRIAC dimmers will work and some will yield better results than others. Contact us to preapprove the dimmer you've selected for your project.
One LL-205-TRIAC dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to
daisy-chain Power Boxes to a single LL-205-TRIAC.
Refer to the LL-205 Installation Guide for additional details and technical specifications.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
22
V-Line® Gen2 V2355 Installation Guide
TYPICAL INSTALLATIONS
Leading / Trailing Edge TRIAC Dimming
Using PS24V75W-E05P Power Box (recommended for short runs)
PS24V75W-E05P*
24V DC
HOT (BLK)
DC COMMON
100W, UL-Listed Class 2
Power Supply
120-277V AC FEED
DIMMING +
685-01859-6
Input Cable
DIMMING -
NEUTRAL (WHT)
GRN/YEL
DIM IN
DIM OUT
*When installing the Power Box outdoors:
- Use PS24V75W-E05PW Power Box
- Use 685-02026-25 Dimming Cable
V2355
To next
Power Box
Dimming Cable*
HOT (BLK)
Dimmer In
3rd Party
TRIAC Dimmer
Operation:
LL-205-TRIAC
120V AC
60HZ FEED
LL-205-TRIAC reads the conventional TRIAC dimmer levels and translates them to i2Systems dimming protocol.
Non-Switched
Circuit
Input may include both Leading and Trailing Edge 120V AC dimmers. Trailing Edge dimmers (those specified as
Low Voltage Dimmers) yield best performance.
Dim Up and Down buttons
for Manual Dimming
Neutral**
The LED bar graph will display Dim levels based on the interpreted TRIAC levels (results may vary).
Dimmer
Out
RED
WHT
RED/WHT
NEUTRAL (WHT)
GRN/YEL
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
23
The TRIAC is not loaded, and in most cases a minimum load will not be required.
LED bar graph indicator
shows selected dim levels
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
**Optional.
Only connect AC Neutral to dimmers with a
Neutral wire hookup. Refer to the dimmer
manual and/or manufacturer for sample
wiring diagrams as wiring varies depending
on dimmer type and hookup.
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Most, but not all, TRIAC dimmers will work and some will yield better results than others. Contact us to preapprove the dimmer you've selected for your project.
One LL-205-TRIAC dims up to 5 Power Boxes. Use i2Systems Dimming Cable 685-01561-X or 685-02026-X to
daisy-chain Power Boxes to a single LL-205-TRIAC.
Refer to the LL-205 Installation Guide for additional details and technical specifications.
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
24
V-Line® Gen2 V2355 Installation Guide
V-Line® Gen2 V2355 Installation Guide
FREQUENTLY ASKED QUESTIONS
LIMITED WARRANTY
Basic Installation
1.1 Limited Warranty. Products are warranted to be free from defects in material and workmanship and to conform substantially to Seller’s then-current (as of the date of
Product shipment) user documentation and specifications for a period of three (3) years from the date of invoice (the “Warranty Period”), provided the Products are used under
those operating conditions (including electrical values and environmental conditions) described in Seller’s then-current user documentation and specifications for
such Products. Seller shall not be liable under the foregoing warranty if Buyer fails to provide Seller with notice of the alleged defect during the Warranty Period.
Q: Can I connect the Gen2 directly to line voltage?
A: No. Connecting the Gen2 directly to line voltage or any voltage higher than 30V DC will damage the fixture and void
the warranty. Use an i2Systems Power Box to convert line voltage to low voltage.
Q:
A:
I see the Gen2 is rated from 20-30V DC. Will the intensity vary over the voltage range?
No. The light output will remain constant over the full range. Based on the Gen2’s constant power design, as the voltage
drops, the current will increase proportionally (conversely, it will go down as the voltage rises), adding additional current
load in the wiring and on the Power Box.
Q: Can I load the Power Box to the full wattage specified (i.e. 75W or 350W)?
A: Yes. The power supplies installed in i2Systems Power Boxes are derated (i.e. a 75W Power Box uses a 100W Power Supply).
Refer to the Power Box Datasheet for additional details.
Q:
A:
Can I use a 3rd party low voltage power supply?
While it is possible to use a 3rd party 24V DC power source, we highly discourage this and doing so may void the Gen2's
warranty. Not all power supplies exhibit the same characteristics and there is the possibility of the power supply being
incompatible or causing damage to the Gen2 fixture. Dimming-Related
Q:
A:
For installations without dimming, what do I do with the orange and violet wires on the Gen2?
The orange and violet wires on the Gen2 are for isolated dimming control. These wires are optically isolated to the Gen2
power and may be cut and capped using best industry practices. Alternatively, tie all orange wires to orange wires and violet
wires to violet wires to synchronize light turn-on when power is applied. Refer to the diagram on page 11.
Q: Is the LightLink LL-205 limited to dimming 5 Power Boxes?
A: No. The LightLink LL-205 is capable of dimming more than 5 Power Boxes. Please refer to the LL-205 Installation Guide for
additional details.
Q: When using the LightLink LL-205 Dimming Module, do I need a 3rd Party Dimmer?
A: No. The LL-205 is often used as a standalone dimmer. This feature is useful for simple installations and/or troubleshooting
dimming installations where the LightLink is able to override the incoming dimming signal to help pinpoint the problem.
Q: Can I mix and match i2Systems Product series on the same LightLink dimmer?
A: Yes. However, contact us prior to doing so, as results may vary, depending on the Product.
1.2 Remedies. In the event a Product does not comply with the foregoing express warranty, Buyer may notify Seller within the Warranty Period and if so notified Seller will,
at Seller’s option: (a) provide a replacement for such Product or defective component or part thereof that has caused the warranty claim (such Product or defective component
or part thereof that has caused the warranty claim, the “Warranty Item”); or (b) refund to Seller the lesser of (1) the amount Seller paid for the Warranty Item, and (2) Seller’s
cost to replace the Warranty Item, in each case as determined by Seller in its sole and absolute discretion following receipt and inspection by Seller of the Warranty Item. For
the avoidance of doubt, “provided a replacement for such Product or defective component or part thereof” expressly does not include any removal or reinstallation costs or
expenses, including without limitation labor costs or expenses. All exchanged Warranty Items shall become the property of Seller. Seller may use either new or remanufactured,
reconditioned or refurbished components or parts (if in like-new condition), or functionally equivalent components or parts, in the furnishing of replacement(s) for any
Warranty Item. Seller’s warranty flows only to Buyer of the products. If the Seller chooses to replace the Product and is not able to do so because it has been discontinued
or is not available, the Seller may replace it with a comparable product.
1.3 Limitations. The foregoing warranty is limited, and does not extend to, and Seller shall incur no liability for: (a) lumen maintenance of the Products; (b) color shift of light
output of the Products; (c) degradation or discoloration of the Product housing(s); (d) mechanical or cosmetic deterioration of the Products associated with normal wear and
tear. For clarity and without limiting the generality of the foregoing, the foregoing warranty does not apply if a Product’s light module continuously generates light at any
intensity, regardless of whether such intensity has decreased since the date of first use of such Product [(viz., warranty coverage only applies in the event that such light module
generates no light or generates light intermittently)]. This limited warranty only applies when the product has been properly wired and installed and operated within the
electrical values, operating range and environmental conditions provided in the Specifications. This warranty does not apply to damage or failure to perform arising as a result
of any Acts of God or from any abuse, misuse, abnormal use or use in violation of any applicable standard, code, or instructions for use including those contained in the latest
National Electrical Code, the Standards for Safety of Underwriters Laboratory, Inc., the Standards for the American National Standards Institute or, in Canada, the Canadian
Standards Association. This Warranty shall become void in the event any repairs or alternations not duly authorized by the Seller in writing are made to the Product by
any person.
Buyer shall convey with each Product distributed to end users this LIMITED WARRANTY, and if Seller determines that the appropriate remedy for a defective product is
refund of Buyer’s purchase price, Buyer shall refund to the end user (or arrange for the refund to the end user of) the full purchase price paid by the end user for such
defective Product.
With respect to Products sold to the Buyer by Seller but not bearing the Seller’s name or sub-brand name, SELLER MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, but will make available to the Buyer upon request but
only to the extent permitted by law and relevant contracts, the warranties of the manufacturer of the relevant product.
1.4 Exclusions; Buyer Indemnification. The foregoing warranty shall be void with respect to defective conditions or non-conformities of the Products resulting from:
(a) modifications of Products not authorized by Seller; (b) misuse, neglect, accident or abuse, improper wiring, repairing, splicing, alteration, installation, storage or
maintenance; (c) use in a manner not in accordance with Seller’s published operating specifications or instructions for the applicable Products; (d) Product defects caused by
Buyer’s combination of the Products with equipment provided or manufactured by third party vendors (unless Seller is advised, in writing, of such proposed combination and
Seller thereafter consents in writing to such combination); (e) breach by Buyer or its employees, partners to whom Buyer sold Product, contractors, representatives, agents or
affiliates, (collectively, “Buyer Parties”) of any obligation herein; or (f) negligent use, application, installation or implementation of Product by any of the Buyer Parties. Buyer
shall indemnify, defend and hold harmless Seller and its officers, directors, agents, employees, affiliates, representatives, successors, and assigns from and against all losses,
liabilities, costs, and expenses (including, without limitation, attorneys’ fees) arising out of out of or in connection with claims by third parties for any loss, damage, or injury
(including death) caused by or alleged to be caused by the circumstances described in this Section 5.4. Buyer shall not join, settle or otherwise attempt to affect or dispose
of any such claim without Seller’s written consent.
1.5 DISCLAIMER. THE EXPRESS WARRANTIES IN THIS SECTION ARE THE ONLY WARRANTIES GRANTED BY SELLER AND THE REMEDIES IN THIS SECTION 5 ARE THE SOLE
AND EXCLUSIVE REMEDIES FOR BREACH OF SUCH WARRANTIES. EXCEPT AS EXPRESSLY PROVIDED IN THIS SECTION 1, SELLER MAKES NO OTHER WARRANTIES, EXPRESS,
IMPLIED OR STATUTORY, AND SELLER EXPRESSLY DISCLAIMS ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF QUALITY,
CONDITION, TITLE, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. No agent, employee, or representative of Seller has any authority
to bind Seller to any affirmation, representation or warranty concerning goods sold by Seller and unless an affirmation, representation or warranty is specifically included herein
or in Seller’s sales acknowledgement, it does not form a part of the basis of any bargain between Seller and Buyer and shall not be enforceable by Buyer.
For i2Systems complete Terms & Conditions of Sale, please visit our website at www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
25
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
Integrated Illumination Systems, Inc.
355 Bantam Lake Road
Morris, CT 06763 USA
tel +1.860.567.0708
fax +1.860.567.2501
[email protected]
Product information is subject to change without notice.
All brand names and product names are trademarks of i2Systems.
© 2012 i2Systems. All Rights Reserved.
www.i2systems.com
090-01965B
26
tel +1.860.567.0708
www.i2systems.com