Bobtail troubleshooting flow diagram
Page 1 - Initial check
WILL NOT
PUMP

PUMP WILL NOT
ENGAGE WITH RF
PTO ENGAGED AND
PTO ENGAGED AND
PTO AND PUMP
WILL NOT ENGAGE





SEE RF & AIR
SYSTEM MODULE
SEE PIPING
SYSTEM MODULE
SEE METER
REGISTER MODULE
SEE RF & AIR
SYSTEM MODULE
SEE ELECTRICAL
MODULE
 NO PUMP PRESSURE  PUMP PRESSURE OK 
Arrow Tank and Engineering, Inc.
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]

NO POWER AT
PRINTER & REGISTER
Bobtail troubleshooting flow diagram
Page 2
REGISTER
MODULE

PUMP WILL NOT
ENGAGE WITH RF

PTO ENGAGED AND
NO PUMP PRESSURE

VERIFY POWER
TO PRINTER
AND REGISTER
(DIGITS SHOWING)

VERIFY METER
VERIFY METER
VAPOR RETURN LINE  DISCHARGE SHUT-OFF
VALVE IS OPEN
TO TANK IS OPEN

VERIFY PRINTER AND
PRINT DELIVERY
PRINT DIAGNOSTIC
REGISTER
 TICKET AND CHECK  TICKET AND CHECK
CABLE CONNECTIONS
FOR ERROR MESSAGES
FOR ERROR MESSAGES
SEE METER
MODULE
Arrow Tank and Engineering, Inc.
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]
DEPLOY DELIVERY
HOSE AND CHECK
FOR KINKS
Bobtail troubleshooting flow diagram
Page 3
METER
MODULE

CRACK OPEN FLEXIBLE
REGISTER POWER ON
CHECK FIRST STAGE
LINE ATTACHED TO
AND TICKET IN
SOLENOID VALVE(S-1)


CENTER OF
PRINTER. CHECK FOR
OPERATION IF
DIFFERENTIAL VALVE
CLICK ON RUN/RESET
EQUIPPED
IF METER LOCKED,
CONSULT OWNERS
MANUAL FOR REPAIR
PROCEDURE
INSPECT DIAPHRAGM
GASKET, FLOAT BALL
LTD BLEED, REED
STRIPS, MAIN VALVE
BLOW DOWN METER
PIPING. REMOVE
 & STRAINER
AND
INSPECT FOR DEBRIS
Arrow Tank and Engineering, Inc.

VERIFY FLOW OR
NO FLOW THRU METER
NOT LOCKED

VERIFY POWER
TO PRINTER
AND REGISTER
(DIGITS SHOWING)

IF VAPOR PRESENT
WITHIN 1-3 MINUTES
DIAPHGRAM AND
S-1 OK

MAKE CERTAIN
TANK IS NOT
OVERLOADED
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]
CHECK FOR PRESENCE
OF LIQUID WITH
 REGISTER
IN ACTIVE
"RUN" POSITION

CONSTANT
LIQUID
PRESENT
Bobtail troubleshooting flow diagram
Page 4
ELECTRICAL
MODULE

CHECK FUSES IN
ELECTRICAL
DISTRIBUTION CENTER
IF EQUIPPED

CHECK 30 AMP FUSE
AND FUSE HOLDER
CONNECTIVITY AT
THE SOURCE
IF NO VOLTAGE
PRESENT TO CONSTANT
HOT ITEMS CHECK
WIRING TO SOURCE
VERIFY POWER
IN THE
DISTRIBUTION CENTER
IF NO VOLTAGE
PRESENT TO KEYED-ON
ITEMS CHECK WIRING
TO SOURCE
VERIFY IF COMPONENT
ACTIVATED WITH
PRESSURE SWITCH
(IE. RF/PARK BRAKE)
IF NO POWER TO
SPECIFIC COMPONENT
 CHECK POWER WITH 
VOM AT COMPONANT
CHECK POWER
HARNESS TO
COMPONENT FOR
DAMAGE
Arrow Tank and Engineering, Inc.
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]
CHECK 30 AMP FUSE
AND FUSE HOLDER
CONNECTIVITY AT
THE SOURCE
Bobtail troubleshooting flow diagram
Page 5
AIR SYSTEM
MODULE
VERIFY TOGGLE
SWITCHES FOR MAIN
VALVE & PTO
ARE ACTIVATED
CHECK FOR AIR
PRESSURE AT AIRLINE
INLET PORT OF RF
SOLENIOD ENCLOSURE
VISUALLY INSPECT
OPERATION OF
ACTUATORS AT
EACH COMPONENT
CHECK FOR PRESSURE
CHECK FOR PRESSURE
AT OUTLET PORT  AT OUTLET PORT OF 
OF SOLENOID
SOLENOID ENCLOSURE
ENCLOSURE - PTO
MAIN VALVE
Arrow Tank and Engineering, Inc.
CHECK EMERGENCY
TRIP BACK OF CAB
MUST BE IN
ACTIVE POSITION
VERIFY PARKING
BRAKE IS SET
SERIOUSLY-PULL IT!
CHECK FOR AIR
PRESSURE AND EXHAUST
AT TOGGLE SWITCHES
AUDIBLE NOISE
VERIFY VOLTAGE
IMPUT TO AIR/ELC
SOLENOIDS FROM
REMOTE DEVICES

IMPUT FROM PARK
BRAKE AIR PRESSURE

SWITCH FOR MAIN
VALVE SOLENOID
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]
IF M2 CHASSIS CHECK
AIR HORN AND SEAT
DOES NOT WORK
= AMU BAD
IMPUT FROM PTO
CHANNEL ON RF
RECEIVER FOR PTO
SOLENOID
Bobtail troubleshooting flow diagram
Page 6
RF SYSTEM
MODULE

PTO WON'T DISENGAGE?
CLEAN EXHAUST
CHECK EXHAUST 
PORT/AIRLINE OF
PORTS ON THE
ROAD DEBRIS AND/OR
SOLENOID ENCLOSURE
ICE AND SNOW
SYSTEM POWER TEST
KEY ON POWER &
OBSERVE LED
BLINK ON RECEIVER
REPLACE BATTERY
IF BAD
CALL BASE
800-924-1010
Arrow Tank and Engineering, Inc.
VERIFY SIGNALS
ACTIVATE HH
BATTERY TEST
RECEIVED AND CHANNEL
FUNCTION
- OBSERVE
 QUICK FLASH=OK 

ACTIVE
LED INDICATOR
MULTIPLE FLASH= BAD
INSIDE/OUTSIDE RECEIVER
ACTIVITY ON RECEIVER
BYPASS RF SYSTEM AT
SOLENOID ENCLOSURE
TO FINISH DELIVERY
AND GET HOME

IF WORKING WITH
ANTENNA
DISCONNECTED
REPLACE ANTENNA
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]

IF NO RESPONSE
DISCONNECT
ANTENNA
AND TRY AGAIN
Bobtail troubleshooting flow diagram
Page 7
PIPING SYSTEM
MODULE

CHECK INTERNAL
VALVE (ISC)
VERIFY OPERATION
OPEN, PARTIAL, CLOSED

IF PUMP ROTATING
VERIFY ALL VALVES
IN PUMPING SYSTEM
ARE OPEN

VERIFY PTO SHAFT
AND/OR PUMP
SHAFT ARE
ROTATING

VERIFY PTO AIR
IF NOT ROTATING
CIRCUIT AND PTO AIR
CHECK FOR BROKEN
 SOLENOID OPERATION
U-JOINT, KEYWAY
IN RF ENCLOSURE
OR PUMP ROTOR


PERFORM PUMP
REFERENCE
CHECK FOR BROKEN
REFERENCE
TESTS AS
OF STEM
ROLL PIN OR MISSING
END OF STEM
 5 - 9 END
O'CLOCK CLOSED  CLEVIS ON VALVE  RECOMMENDED BY
12 - 6 O'CLOCK OPEN
PUMP MANUFACTURER
(WAIT 10 MINS IF SLUGGED)
AND ACTUATOR

IF PUMP FOUND
TO BE DAMAGED
REPAIR AS NEEDED
Arrow Tank and Engineering, Inc.
650 North Emerson, Cambridge, MN 55008 • phone: 763-689-3360 • toll free: 800-333-5532 • email: [email protected]
VERIFY PTO AIR/ELECT
SOL SWITCH AND
WIRING NEAR MOUNTING
FLANGE ON TRANS