Download error codes - GymStore.com

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Cybex Service Corporation
ERROR CODES
BIKES
3610, 3670, 3710, 3770, The BIKE and SEMI
ERROR
System stall
X
DESCRIPTION
System will not calibrate
Large red X displayed
PROBABLE CAUSE
Belt worn, broken or off flywheel
Replace display or send in for repair
3900, 3950, 600C and 600R, Upright & Recumbent
ERROR
3
LO-BAT
DESCRIPTION
Calibration failure
Low battery voltage
PROBABLE CAUSE
Reset to original settings
Charge battery to 6 volts
BikeMax 1000 (Friction Belt)
ERROR
5
DESCRIPTION
No Slack
PROBABLE CAUSE
Replace lower board
CROSS TRAINING
600A, ARC Trainer
ERROR
bAd0
bAd2
bAd3
Err3
Err5
Err7
ErrE
DESCRIPTION
Bad Checksum
Internal RAM error
Watchdog timeout
Speed sense lost
No index switch sense within timed limit
EEPROM error, memory lost
Index switch always on
PROBABLE CAUSE
Recycle power, replace display board
Recycle power, replace display board
Recycle power, replace display board
Check speed sensor disc, lower board and brake
Calibrate elevation motor, replace motor, replace lower board
Replace display board
Calibrate elevation motor, replace motor
600H, The HIKER
ERROR
3
LO-BAT
DESCRIPTION
Calibration failure
Low battery voltage
PROBABLE CAUSE
New Display or EPROM? Reset to original settings
Charge battery to 6 volts, Replace battery
Cybex International Inc. • 10 Trotter Drive Medway MA 02053 • 508-533-4300 • Fax 508-533-5183
Cybex Service Corporation
STEPPERS
400S, 500S, 700S, 800S & Climbmax models
ERROR
5
DESCRIPTION
No Slack
6
7
No Brake
Can’t slow down
PROBABLE CAUSE
Test switch in test mode, Adjust switch, Possible cut in display
cable.
Adjust slack switch, replace motor
Check RPM sensor and disk
Trotter 3300
ERROR
DESCRIPTION
PROBABLE CAUSE
1
2
3
NOVRAM error
No speed signal
No speed lock
Reseat EPROM, Replace, if not display needs repair
Does motor rotate? Check LED on MCB and pick-up
Replace MCB
Cybex International Inc. • 10 Trotter Drive Medway MA 02053 • 508-533-4300 • Fax 508-533-5183
Cybex Service Corporation
TREADMILLS
Trotter Elite, Sport & Pro
ERROR
DESCRIPTION
PROBABLE CAUSE
bAd0
Bad Checksum
bAd2
Internal RAM error
bAd3
Watchdog timeout
Err1
Belt didn’t start (or no speed sense)
Err2
Under speed (2mph for 2 seconds
without correction in process)
Speed sense lost
Turn the treadmill to the off (O) position and back on, Replace
display board
Turn the treadmill to the off (O) position and back on, Replace
display board
Turn the treadmill to the off (O) position and back on, Replace
display board
Perform speed calibration, check speed sensor, check motor
brushes, drive motor, display cable then lower board
Perform speed calibration procedure, check speed sensor,
check belt and deck then drive motor
Check speed sensor, lower board, drive motor then display
cable
Check elevation motor calibration, then lower board
Err3
Err5
Err6
Err7
Err9
ErrE
No 0 switch sense within timed limits.
This is declared when the timed
elevation reaches -2% without tripping
the index
Over speed (1 mph for 1 second or 2
mph for 0.2 seconds without correction)
EEPROM error (memory lost, loads
new defaults, enters Test Mode)
Brush wear too low. Indicator has been
activated for over 100 miles
0% always on (or switch disconnected
or wired backwards). This means that
timed elevation has gone up 2% and
the index is still sensed
Check speed sensor
Replace display board
Check and replace motor brushes
Check elevation motor calibration
300T
ERROR
DESCRIPTION
PROBABLE CAUSE
1
3
4
5
6
7
No speed signal at startup
Loss of speed signal
No frequency lock
Elevation error
Over speed
Loss of NOVRAM data
With or without belt movement? Lower board or brushes
Check speed sensor, sensor gap and cable
Noisy line voltage, Install dedicated outlet
Check voltage to motor, potentiometer and cable
Check speed sensor and cable and cap
Reseat EPROM, Replace, if not display needs repair
Cybex International Inc. • 10 Trotter Drive Medway MA 02053 • 508-533-4300 • Fax 508-533-5183
Cybex Service Corporation
600T
ERROR
DESCRIPTION
PROBABLE CAUSE
Born
Bad0
Bad1
Bad2
Bad3
Bad4
1
Un-initialized EEPROM
EPROM checksum failure
Faulty microprocessor reset
Internal RAM error
Watchdog fault type 1
Watchdog fault type 2
No speed signal at startup
Will load defaults, and enter test mode, cycle power
Replace EPROM
Replace Microprocessor
Replace display board
2
Under speed, drops 2 MPH for 2
seconds
Loss of speed signal
Elevation switch did not find 0%
Over speed, 1 MPH over for 1 sec. Or 2
MPH for .2 sec.
Memory lost, loads new defaults, enters
test mode
Incorrect rate of acceleration or
deceleration of belt speed.
Brush wear too low, activated 100
miles(161KM) ago
0% switch always on
3
5
6
7
8
9
E
With or without belt movement? Speed sensor, lower board,
brushes
Check speed sensor, drive motor, belt, deck
Check speed sensor, sensor gap and cable
Cycle power, check cables and elevation motor
Check speed sensor, cable
Cycle power, replace EPROM, upper display board
See error 2 & 6
Replace both brushes
Check elevation cables and motor
710T, 645, 585, 545, 535, 525, 540, 410T, CXT
ERROR
DESCRIPTION
PROBABLE CAUSE
1
No speed signal at startup
2
Excessive current draw
3
4
5
14
50
70
Loss of speed signal
No frequency lock
Elevation error
Software error
Over speed
Loss of NOVRAM data
With or without belt movement? 130 VDC spike? SCR or
brushes
Check amp draw with & without load, Belt & Deck, or motor
circuit
Check speed sensor, sensor gap and cable
Noisy line voltage, Install dedicated outlet
Calibrate, Check voltage to motor, potentiometer and cable
Reseat EPROM, Replace
Check speed sensor and cable, SCR, cap, brake on XL models
Reseat EPROM, Replace, if not display needs repair
700T, 640, 510, 400T
ERROR
DESCRIPTION
PROBABLE CAUSE
1
No speed signal at startup
2
Excessive current draw
3
4
5
6
7
Loss of speed signal
No frequency lock
Elevation error
Over speed
Loss of NOVRAM data
With or without belt movement? 130 VDC spike? SCR or
brushes
Check amp draw with & without load, Belt & Deck, or motor
circuit
Check speed sensor, sensor gap and cable
Noisy line voltage, Install dedicated outlet
Calibrate, Check voltage to motor, potentiometer and cable
Check speed sensor and cable, SCR and cap
Reseat EPROM, Replace, if not display needs repair
Cybex International Inc. • 10 Trotter Drive Medway MA 02053 • 508-533-4300 • Fax 508-533-5183
Cybex Service Corporation
900T, 685
ERROR
DESCRIPTION
PROBABLE CAUSE
1
2
3
4
6
8
10
11
12
13
14
15
16
PWM Shutdown
Belt speed loss
No belt speed
Belt over speed
Motor over voltage
Power fault
Elevation over speed
No elevation speed
Elevation limit
Elevation time limit
Communication time-out lower
Line tick loss
Loss of NOVRAM data
17
18
19 and
higher
No lower board
Communication time-out upper
Software errors
Excessive drive motor current
Speed signal lost for more than 1 second
No speed signal detected at startup
Belt speed exceeded the set speed by +/- 1 MPH
Motor voltage exceeded 200 VDC for 200 milliseconds
Drive motor voltage below 190 VDC for 5 seconds
Elevation motor exceeded 3800 RPM for 2 seconds
No movement detected when elevation powered
Right side limit switch is open
Motor driven for 60 seconds without reaching limit
No message from upper board for 3 seconds
Timing lost from lower board
NOVRAM data does not match EPROM version, Replace
EPROM
No info received from lower board at startup
Signal interrupted from PWM to DMD
Software error occurred in program, replace EPROM then
Micro
CXT Fat Pak
ERROR
DESCRIPTION
PROBABLE CAUSE
1
2
3
Overspeed
Underspeed
Excessive current draw
Check speed sensor and cable, SCR and cap
Check speed sensor and cable, SCR and cap
Check amp draw with & without load, Belt & Deck, or motor
circuit
Cybex International Inc. • 10 Trotter Drive Medway MA 02053 • 508-533-4300 • Fax 508-533-5183
Cybex Service Corporation
Q25ci, Q20ci
ERROR
DESCRIPTION
PROBABLE CAUSE
E-1
E-2
E-3
E-4
E-5
E-6
Speed sensor failure
Intermittent speed sensor reading
Elevation malfunction
Processor failure
Zero crossing failure
Processor failure
Check gap, target scratched? Replace speed sensor
Incorrect gap, replace sensor
Fuse on LCB, Sensor, limit switch, motor or LCB
Replace processor
Noisy line, replace LCB
Replace processor
Q45 the MILL, Q31ci, Q33ci, Q35ci
ERROR
DESCRIPTION
PROBABLE CAUSE
1
2
3
4
5
6
7
ERR
Start-up power error
Maximum power error
Processor failure
Speed sensor failure
Intermittent speed sensor reading
Processor checksum error
Line frequency error
Lift error
Speed sensor, poor connection, motor
Low line voltage, on extension cord?
Replace processor
Check gap, target scratched? Replace speed sensor
Incorrect gap, replace sensor
Replace processor
50 or 60 Hz? Change in setup mode
Fuse on LCB, Sensor, limit switch, motor or LCB
Cybex International Inc. • 10 Trotter Drive Medway MA 02053 • 508-533-4300 • Fax 508-533-5183