Download 74AS02 - Unicorn Electronics

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Flip-flop (electronics) wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Multimeter wikipedia , lookup

Radio transmitter design wikipedia , lookup

Ohm's law wikipedia , lookup

Amplifier wikipedia , lookup

Oscilloscope history wikipedia , lookup

Current source wikipedia , lookup

Power MOSFET wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Two-port network wikipedia , lookup

Integrating ADC wikipedia , lookup

Surge protector wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

CMOS wikipedia , lookup

Wilson current mirror wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Operational amplifier wikipedia , lookup

Voltage regulator wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power electronics wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Current mirror wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
SN54ALS02A, SN54AS02, SN74ALS02A, SN74AS02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SDAS111B – APRIL 1982 – REVISED DECEMBER 1994
•
SN54ALS02A, SN54AS02 . . . J PACKAGE
SN74ALS02A, SN74AS02 . . . D OR N PACKAGE
(TOP VIEW)
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
1Y
1A
1B
2Y
2A
2B
GND
description
These devices contain four independent 2-input
positive-NOR gates. They perform the Boolean
functions Y = A + B or Y = A • B in positive logic.
The SN54ALS02A and SN54AS02 are
characterized for operation over the full military
temperature range of – 55°C to 125°C. The
SN74ALS02A and SN74AS02 are characterized
for operation from 0°C to 70°C.
B
H
X
L
X
H
L
L
L
H
13
3
12
4
11
5
10
6
9
7
8
VCC
4Y
4B
4A
3Y
3B
3A
1A
1Y
NC
VCC
4Y
1B
NC
2Y
NC
2A
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
4B
NC
4A
NC
3Y
2B
GND
NC
3A
3B
A
OUTPUT
Y
14
2
SN54ALS02A, SN54AS02 . . . FK PACKAGE
(TOP VIEW)
FUNCTION TABLE
(each gate)
INPUTS
1
NC – No internal connection
logic symbol†
1A
1B
2A
2B
3A
3B
4A
4B
2
3
logic diagram (positive logic)
≥1
5
1
1Y
1B
4
6
2Y
10
3Y
3A
3B
11
12
2A
2B
8
9
1A
13
4Y
4A
4B
2
3
1
1Y
5
6
4
2Y
8
9
11
12
10
13
3Y
4Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
Copyright  1994, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ALS02A, SN54AS02, SN74ALS02A, SN74AS02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SDAS111B – APRIL 1982 – REVISED DECEMBER 1994
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54ALS02A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS02A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS02A
VCC
VIH
Supply voltage
High-level input voltage
SN74ALS02A
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
2
2
VIL
Low level input voltage
Low-level
0.8‡
0.7§
IOH
IOL
High-level output current
– 0.4
Low-level output current
– 55
125
V
V
4
TA
Operating free-air temperature
‡ Applies over temperature range – 55°C to 70°C
§ Applies over temperature range 70°C to 125°C
UNIT
0
0.8
– 0.4
mA
8
mA
70
°C
V
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
VOH
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = –18 mA
IOH = – 0.4 mA
VOL
5V
VCC = 4
4.5
IOL = 4 mA
IOL = 8 mA
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
IIL
IO#
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
ICCH
ICCL
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0
VI = 4.5 V
SN54ALS02A
TYP¶
MAX
MIN
SN74ALS02A
TYP¶
MAX
MIN
–1.5
VCC – 2
–1.5
VCC – 2
0.25
0.4
V
V
0.25
0.4
0.35
0.5
0.1
– 20
UNIT
0.1
V
mA
20
20
µA
– 0.1
– 0.1
mA
– 112
mA
mA
– 112
– 30
0.86
2.2
0.86
2.2
2.16
4
2.16
4
mA
¶ All typical values are at VCC = 5 V, TA = 25°C.
# The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS02A, SN54AS02, SN74ALS02A, SN74AS02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SDAS111B – APRIL 1982 – REVISED DECEMBER 1994
switching characteristics (see Figure 1)
FROM
(INPUT)
PARAMETER
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
TO
(OUTPUT)
SN54ALS02A
tPLH
tPHL
A or B
Y
UNIT
SN74ALS02A
MIN
MAX
MIN
MAX
1
16
1
12
1
11
1
10
ns
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54AS02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74AS02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS02
SN74AS02
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.8
0.8
V
High-level output current
–2
–2
mA
IOL
TA
Low-level output current
20
20
mA
70
°C
High-level input voltage
2
Operating free-air temperature
2
– 55
125
V
V
0
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
VOH
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = –18 mA
IOH = – 2 mA
VOL
II
VCC = 4.5 V,
VCC = 5.5 V,
IOL = 20 mA
VI = 7 V
IIH
IIL
IO¶
VCC = 5.5 V,
VCC = 5.5 V,
VI = 2.7 V
VI = 0.4 V
VCC = 5.5 V,
VCC = 5.5 V,
VO = 2.25 V
VI = 0
ICCH
ICCL
SN54AS02
TYP§
MAX
MIN
SN74AS02
TYP§
MAX
MIN
–1.2
VCC – 2
–1.2
VCC – 2
0.35
– 30
0.5
V
V
0.5
V
0.1
0.1
mA
20
20
µA
– 0.5
– 0.5
mA
– 112
mA
5.9
mA
– 112
3.7
UNIT
5.9
0.35
– 30
3.7
VCC = 5.5 V,
VI = 4.5 V
12.5
20.1
12.5
20.1
mA
§ All typical values are at VCC = 5 V, TA = 25°C.
¶ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SN54ALS02A, SN54AS02, SN74ALS02A, SN74AS02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SDAS111B – APRIL 1982 – REVISED DECEMBER 1994
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
SN54AS02
tPLH
tPHL
A or B
Y
SN74AS02
MIN
MAX
MIN
MAX
1
6
1
4.5
1
5
1
4.5
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
UNIT
ns
SN54ALS02A, SN54AS02, SN74ALS02A, SN74AS02
QUADRUPLE 2-INPUT POSITIVE-NOR GATES
SDAS111B – APRIL 1982 – REVISED DECEMBER 1994
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
From Output
Under Test
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
1.3 V
1.3 V
0.3 V
0.3 V
Data
Input
tw
th
tsu
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
[3.5 V
1.3 V
tPHZ
tPZH
Waveform 2
S1 Open
(see Note B)
1.3 V
VOL
0.3 V
VOH
1.3 V
0.3 V
[0 V
3.5 V
1.3 V
Input
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
Out-of-Phase
Output
(see Note C)
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5