Download 6 Energy Meter

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Grid energy storage wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Galvanometer wikipedia , lookup

Rectiverter wikipedia , lookup

Distributed generation wikipedia , lookup

Coilgun wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Transcript
1
EXPERIMENT NO. 6
AIM: STUDY AND CALIBRATION OF SINGLE PHASE ENERGY METER.
APPRATUS REQUIRED:
Sl. No.
1.
2.
3.
4.
5.
Name
Wattmeter
Voltmeter
Ammeter
Lamp Load Bank
Single Phase Energy Meter
Range
0-750 Watts
0-300 volts
0-10 A
1 Kw
600 R/KWH, 50 Hz
Quantity
1
1
1
1
1
THEORY:
The total power consumed by a load during an interval of time is ENERGY.
Where, E=Energy, P= Power, T=Time
If the voltages & currents not constant & have n-values over the time t, then
It can also be expressed as continuous integral of Power i.e.,
The unit of energy is Watt second or joule. But its commercial unit is Kilowatt-hours or KWh
which is defined as the energy consumed by a load of 1000 watts over a period of one hour.
Energy Meter
2
Induction type energy meters are most commonly form of an A. c. KWh meter used to
measure the energy consumed in any a.c. circuit in a prescribed period when supply voltage
and frequency are constant, in day today life & in industrial installation. Energy meter is an
integrating instrument which measure the total quantity of electrical energy supplied to the
circuit in a given period. These meters measure electrical energy in Kilowatt hours.
PRINCIPLE: The Basic principle of induction type energy meter is electromagnetic induction.
When an alternating current flows through two suitably located coils (Current coil &
Potential Coil) produces rotating magnetic field which is cut by the metallic disc Suspended
near to the coils, thus, an e.m.f. is induced in the thin Aluminum disc which circulates eddy
currents in it. By the interaction of Rotating magnetic field & eddy currents, torque is
developed & causes the disc to rotate. This is the same principle which is applied in the
single-phase induction motors.
Construction: An Indction type single phase energy meter, has following main parts of the
operating mechanism:
1.
2.
3.
4.
Driving System
Moving System
Braking System
Registering System
DRIVING SYSTEM develops torque to rotate the moving system. It consists of two
electromagnets one is formed by current coil & other one is by voltage coil or pressure coil.
MOVING SYSTEM essentially consists of an aluminum mounted on the spindle which is
supported by Pivot-jewel Bearing system. Since there is not control spring, the disc makes
continuous revolution under the action the deflecting torque.
BRAKING SYSTEM consists of a permanent magnet of C shaped covering a part of rotating
disc to provide braking torque. By changing the position of breaking magnet, the Flux
linkage with the disc can be changed, this torque is opposite to driving torque.
REGISTERING SYSTEM keeps the record of energy consumed by load through worm wheel or
pinion gear mounted with spindle of moving disc.
WORKING
When the energy meter is connected in the circuit, the current coil carries the load current
and the pressure coil carries the current proportional to the supply voltage. The magnetic
field produced by the SERIES magnet (series coil) is in phase with the line current & the
magnetic field produced by the shunt magnet (pressure coil) is in quadrature with the
applied voltage (since the coil is highly inductive). Thus, a phase difference exists between
the fluxes produced by the two coils. This sets up a rotating field which interacts with the
3
disc and produces a driving torque and, thus, disc starts rotating. The number of revolutions
made by the disc depends upon the energy passing through the meter. The spindle is geared
to the recording mechanism so that electrical energy consumed in the circuit is directly
registered in KWh. The speed of the disc is adjusted by adjusting the position of the
breaking magnet. For example, if the energy meter registers less energy than the energy
actually consumed in the circuit, then the speed of disc has to be increased which is
obtained by shifting the magnet nearer to the centre of the Disc and vice-versa.
At constant angular speed the power
is proportional to the angular speed in r.p.s.
We calibrate w and energy meter by time test.
Let K be the meter constant of energy meter, which is the number of revolution per KWh
energy consumption. When connected to measure energy, if disc makes R number of
revolution in t seconds. Then the reading of energy meter is:
Let KW= Power in Kilowatt from wattmeter reading.
R= No. of revolution made by disc in ‘t’ Sec.
Energy recorded by meter under test
Let the wattmeter reading be Kw watts of energy calculated from the wattmeter & stop
watch is given by
Energy consumed by wattmeter (Es) =
Percentage Error =
=
PROCEDURE:
1. Make the connection as per the circuit diagram.
2. Decide the number of revolution to take the readings. It should neither be too small
nor be too large. You may keep this between 4-6 Revolutions.
3. Keep the load at minimum and switch on the power supply.
4. Take the reading of Et, W and t from the energy meter, wattmeter and stop watch
respectively. Calculate Es & Percentage error.
5. Increases the load in 5-10 steps upto rated value of the energy meter and take the
readings. Switch off the supply.
4
From the observation of the magnitude of error at different loads predict the nature of the
error as given below:
1. When supply is on and there is no load, i.e., when its pressure coil is only energized,
if meter reads energy by rotation of disc it is certainly “CREEP ERROR”.
2. If at very high loads, it reads less it is called as FRICTIONAL ERRROR.
3. 3. If at very high load meter reading is less, it may be due to “DYNAMIC BREAKING
TORQUE” and requires over load compensation.
CIRCUIT DIAGRAM:
OBSERVATION TABLE:
Sl.
Powe Time No.
of
No.
r
(sec) Revolutions(
(KW)
R)
(KWh)
PRECAUTIONS:
1. Make sure the connections carefully and get it checked by your instructor before you
switch ON the supply.
2. Take the readings carefully, especially the energy meter reading and stop watch
operation must be simultaneous.
3. Don’t touch the live wires.
4. Do not the energy meter beyond its rating.
5. The input voltage must be kept constant with the help of autotransformer.
RESULT:
The given 1-phase induction type energy meter is calibrated with the help of a standard
wattmeter and stop watch. It is found that percentage error does not remain constant
rather it varies in magnitude from no load to full load.