Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Operating Manual Sequential Direction Light Set Ref.No. 120910-1 - Sequential Direction Light Set, 10-fold, Type 22/3, 230/12V Ref.No. 120910-5 - Sequential Direction Light Set, 5-fold, Type 22/3, 230/12V Ref.No. 120910-11 - Sequential Direction Light Set, 10-fold, Type 22/3, 12V Ref.No. 120910-15 - Sequential Direction Light Set, 5-fold, Type 22/3, 12V 297075-1 - 03/2009 Structure of the Sequential Direction Light Set: The Sequential Direction Light Set consists of a control unit with battery box and 10 lamps with different cable lengths (type 23/2 - 5 lamps). Maximum length of the lamp chain is 100m each set (type 23/2 maximum 50m). The control unit is slipped into the holder in the battery box which should be placed between the fifth and sixth lamp. Operation by mains supply Operation by battery and mains supply / charger Battery operation The lamps themselves must be placed at a distance of 10 m to the next one by following the numbers from 1 to 10. The lamp cables have to be put into the battery box by using the hole at the handle of the box and then connected according to numbering. Cable length of the lamps: No. 1+10 No. 2+ 9 No. 3+ 8 No. 4+ 7 No. 5+ 6 = = = = = 1 2 3 4 5 6 7 8 9 10 50m 40m 30m 20m 10m Operating Manual Sequential Direction Light Set page 2 of 10 297075-1 - 03/2009 Voltage supply of the Sequential Direction Light Set: The control unit has two input sockets for the voltage supply where a 12 volt rechargeable battery or a mains supply / charger 230 volt can be connected. When a mains supply / charger and a rechargeable battery are connected the battery is automatically charged when mains voltage is available. In this case the yellow LED on the mains supply / charger starts lighting. When the mains voltage fails the Sequential Direction Light Set is automatically operated by the rechargeable battery. It can also be operated without a rechargeable battery by using the mains supply / charger 230 volt. In this case the battery connection has to be removed for safety reasons (danger of short circuit at the pole clips). When the Sequential Direction Light Set is used only with the mains supply / charger program 5 "Blink 1 sync." can not be used. Attention ! It is absolutely necessary to disconnect the connecting cable for the rechargeable battery when the set shall be used with mains voltage only! Attention! To be followed when connecting the mains voltage! The mains plug must be inside the battery box (water protection). Take care that all relevant rules are observed! The Sequential Direction Light Set must only be put into operation when the lid of the battery box is properly locked! The control unit must be protected against rain at any time. Therefore the connecting cables have to be fed through the opening at the handle. Operating Manual Sequential Direction Light Set page 3 of 10 297075-1 - 03/2009 Display and keys Display: When selecting a program first line: second line: program function When set is switched on first line: second line: symbolic indication of the function brightness mode and battery voltage When entering the parameters first line: second line: parameter value set Main switch of the Sequential Direction Light Set. When the set is switched on all other keys are without function. Setting the parameters Program selection resp. parameter selection Change of parameters Operating Manual Sequential Direction Light Set page 4 of 10 297075-1 - 03/2009 Program selection When the Sequential Direction Light Set is switched off a program can be selected by the keys !. The symbolic program sequence is indicated in the second line, but at a slower rate than the original speed of the lamps. After a program has been selected the set can be started by pressing key I/O Attention ! When connecting the voltage the set always starts with the last program used and at the last switching state (On or Off). Programs: 1. Guide light single (factory setting) Only one lamp at the time is on. Cycle time ca. 1,6 seconds. 2. Guide light overlapping Two lamps are always on at the same time (overlapping). Cycle time ca. 1,2 seconds. 3. Light building up The lamp chain builds up from 1 to 10 and then switches off. Cycle time ca. 1,6 seconds. 4. Light building up and declining The lamp chain builds up from 1 to 10 and then declines in the same sequence. Cycle time 3,2 seconds. 5. Blinklight synchronous All 10 lamps light up at the same time, blink frequency 1 Hz, on-time 200 ms 6. Blinklight asynchronous All uneven lamps (1, 3, 5…) light up at the same time, alternating with all even lamps (2., 4., 6…). Blink frequency 1 Hz 7. Permanent light All lamps light up permanently. Operating Manual Sequential Direction Light Set page 5 of 10 297075-1 - 03/2009 Parameter settings Parameters can only be set when the Sequential Direction Light Set is switched off. The parameter menu is selected by pressing the key with the screw driver symbol. The parameter menu is leafed through by the keys !, changes are made by the keys +/-. Settings: 1. Language Choice: German English 2. Day/night adaptation Choice: Automatic day/night operation (factory setting) Only daytime operation (always maximum brightness) Only nighttime operation (always minimum brightness + basic light) 3. Kind of lamp Choice: Halogen lamps LED lamps Attention! Before putting into operation check the lamp selection. When the control unit is supplied as part of a set the correct selection is pre-set by the factory. 4. Type of set Choice: Standard (normal 10-fold set) Switzerland (first and last lamp permanent light) 5-fold set (only lamp output 1-5 are used) 5. Maximum brightness Setting of the maximum brightness of the lamps at daytime between 50 % and 100 %Max. 6. Minimum brightness Setting of the minimum brightness of the lamps at nighttime between 10 % and 60 %Max. 7. Background light Setting of the brightness of the basic light at nighttime operation between 5 % and 30 % Operating Manual Sequential Direction Light Set page 6 of 10 297075-1 - 03/2009 8. Series operation Choice: Synchronous parallel (factory setting) All sets start their cycle parallel at the same time Synchronous in series All sets run in series, e.g. a single guide light runs through from the first lamp to the last lamp When the chain of sets is interrupted during series operation the remaining sets still work in this mode. The first control unit of the remaining chain automatically takes the position of the main controller. 9. Display lighting The time until the display lighting switches off can be set between 1 and 60 minutes. Factory setting is 15 minutes. The lighting is activated again when a key is pressed. When 0 minutes is set the display stays lit. 10. PIN lock The parameter menu can be protected by a PIN lock. In this case an own PIN can be selected. Choice: No change - the PIN setting remains No PIN - the PIN lock is lifted by pressing key ! Select PIN - an own PIN can be selected by pressing key !, PIN lock is activated Attention ! Do not forget the PIN! When the PIN is lost contact the Nissen service! Leaving the parameter menu: The menu can be left by pressing the key with the screw driver symbol. The display shows -- Store ?– (- no) (+ yes) When the - key is pressed the former settings remain and the parameter menu is left. When the + key is pressed the new settings are stored and the parameter menu is left. Operating Manual Sequential Direction Light Set page 7 of 10 297075-1 - 03/2009 Entering of the PIN (selection of the numbers) When the PIN is requested the message PIN = 0 0 0 0 OK is indicated. The four-digit PIN is entered by using the keys +/- for the numbers, the cursor is moved by the arrow keys. When the cursor is moved behind the last number the PIN is entered. If it is correct the parameter menu opens up, if it is wrong the control unit switches back to the original state. Series operation Any number of Sequential Direction Light Set s can be connected in series. For this the output for series operation of the firs set must be connected with the second set and so forth. The complete series is controlled by the first control unit, including the automatic brightness adaptation. During series operation all settings of the first Sequential Direction Light Set are taken over by the other sets connected. The other control units only indicate "Slave Operation" and their own battery voltage. Operating Manual Sequential Direction Light Set page 8 of 10 297075-1 - 03/2009 Technical Data Mains supply / charger: Input voltage: Current consumption: Output voltage: Output current: Characteristic charging curve: Rechargeable battery: Range of temperature: 230 Volt AC 50 Hz (<200 V reduced output) max. 1,5 Ampere 12 to 14,4 Volt 17 Ampere IUoU Lead acid and acid battery 12 Volt max. 230 Ah -25 to +85 C° Control unit: Input voltage: Current consumption: Range of temperature: 12 Volt DC max. 16 Ampere -25 to +85 C° Operating time with battery 12V 180Ah Guide Light simple Guide Light overlapping Light building up Light building up and declining Blinklight synchronous/asynchronous Permanent light 70 hours 47 hours 22 hours 22 hours 22 hours 19 hours Operating Manual Sequential Direction Light Set page 9 of 10 297075-1 - 03/2009 General Safety Instructions 1. Working area Disorder in the working area increases the danger of accident. Tools and equipment have to be put in their proper places. Unused cable which is lying around at the building-site has to be removed. Lines under voltage have to be protected in a way that a damage by vehicles is impossible. 2. Correct working and protective clothing To prevent head injuries by parts or tools falling down, safety helmets have to be worn when working with machines or equipment higher than the height of the head. Non-slip shoes have to be worn, if possible protective shoes. If possible good visible protective clothing must be worn at road building sites. At dust producing work a respiratory protection mask has to be used. 3. Cables and Feed lines Cables and feed lines have to be traction relieved. Only cables which are approved for the use in free atmosphere are allowed. When using a higher current drain take care for the cross section of the cable The protective conductor has to be connected. The cables must be protected against heat, oil and sharp edges. Never carry equipment and tools with the cable. The cable must not be used for taking off the plug from the socket. Plug and cable have to be controlled regularly. In case of damage they must be repaired or renewed by an expert. 4. Protective installations Damages at protective installations have to be corrected immediately. This is as well valid for electrical fuses. Only fuses with the required current intensity and sensibility (slow or speedy) have to be installed. If the damage can not be eliminated by this, the protective installations must be checked by an expert. 5. Power supply units Before opening units which have to be repaired take off the power supply plug. Only experts at special operating positions are allowed to work with units under voltage. 6. Spare parts For repairing only original spare parts have to be used. 7. Equipment and tools Avoid unintended start. Do not put your finger on the switch or cable when carrying tools which are connected to the mains. Make sure that the switch is switched off when connecting to the mains. Before switching on make sure that the keys and setting tools are removed. Perform servicing and maintaining of equipment and tools according to special safety hints and service instructions. Tools and equipment have to be secured in a way that they are protected against unauthorized use. Do not use tools and equipment for purposes they are not destined for. Do not overload your tools and equipment. You are working better and safer in the stated range of capacity. Never use electrical equipment near burnable fluids or gases. 8. Protection against electric shock When working with electrical equipment avoid body contact with grounded parts, e.g. tubes of heating elements. 9. Accumulators in equipment and tools Accumulators have to be watched constantly and maintained according to given service instructions. 10. Safety For your own safety pay attention to the general and special safety hints of the manufacturers. Only by doing this you can protect yourself against accidents. Operating Manual Sequential Direction Light Set page 10 of 10 297075-1 - 03/2009