RM112 TAKEMOTODENKI CORPORATION Current Input Digital Power Meter RM-112 Type RM−112−□□ □ − □ □ □ □ Specification Standards:JIS C 1102, JIS C 1111 Input(Upper) 0: Nothing 1: 30V DC Housing: Flame-proof ABS Resin, UL94V-0 Screw Terminal: Input Terminal・ Power Terminal:M4 Output Terminal・ External Terminal Input:M3 2: 50V DC 3: 150V DC Digital Display:Below 5 digits, Orange LED, Numeric Height 10mm 4: 300V DC Isolation:Between Mutual input, Input− Output− Auxiliary Power―Display Switch 5: 1mA DC With Multiplier(V Display) 6: 60mV DC With Shunt(A Display) Sampling Cycle: 400μ s 7: 100mV DC With Shunt(A Display) Blackout Compensation:Scale is stored in non-volatile memory. 8: 1∼5V DC (V Display) A: DC Watt(Calculated Value Display) E: 5A AC F: 1A AC G: AC150V(Rating 110V) Input Specification Measuring Item Current DC H: AC300V(Rating 220V) J: Ah( Integration) K: Watt-hour( Integration) Rated Input ±60mV DC ±100mV DC ±300V DCま で ダイレクト Voltage DC L: W(Calculated Value)/Wh(Integration) Watt DC Code:Same as Upper Current AC Input(Lower) Voltage AC Code:Same as Upper Ah Watt-hour External Output 0: Nothing Use of Multiplier (Internal Impedence: 1.1kΩ) 1∼ 5V DC ※W & Wh are displayed in Lower display only. Input(Middle) ±1mA DC Note Use of Shunt (Internal Impedence: 10kΩ) Current×Voltage 5A AC 1A AC 110V AC 220V AC 5.0 Ah Max 150V Max 300V FS=Rated Shunt FS=Current×Voltage ※1 Striking Current: 20mA(at Rated 5A) ※2 No-load Calculating ※1 ※2 1: 4∼20mA 2: RS-485 Output Specification 4: 0∼1mA 5: 0∼10V 6: 1∼5V 7: 0∼5V Auxiliary Power 1: 85∼ 143V DC/ 85∼264V AC 2: 20∼ 30V DC External Operation Rated Input 1: 85∼ 132V AC or 85∼143V DC 2: 20∼ 30V DC 3: 170∼264V AC LED BRIGHTNESS No Symbol:Default F: High Brightness LED・with screen filter ◆Analog Output Allowable Load Resistance & Output Impedence Range 4∼ 20mA DC 0∼ 1mA DC 0∼ 10V DC 1∼ 5V DC 0∼ 5V DC Max Load Resistance 500Ω 10kΩ 5kΩ ※“-“ minus at each output channel is common. ◆Pulse Output Scale Factor: 0.01, 0.1, 1, 10, 100kWh/pulse (Default: 1kWh/pulse) Contact Capacity: 110V DC /110V AC 0.1A(Resistance Load) Ordering Information Example ・Type:RM-112-111-111 ・Special Code: On-resistance:typically 30Ω , max50Ω Pulse Width:100∼150ms(Output Range: Less than 12,000 pulse/h) RM112 ◆Communication Output Standards:RS-485 Withstand Voltage: Between Input− Output− Aux. power− earth, Speed: 1200・2400・4800・ 9600・19200 alternative 2000V AC 1 min. Synchro System: Asynchronous Between electric circuit− earth Communication Control System:Polling/Selecting (No applying voltage to output terminal) Character Code: ASCII 2000V AC 1 min. Lightning Impulse:all electric terminal―earth terminal 4.5kV Data Type: Blackout Compensation: Start Bit Data Parity Bit Stop Bit 1 bit 7 bits Even 1 bit Internal data & integrated value, for example,rated current & voltage are stored in nonvolatile memory inside when auxiliary power stops. Transmission Distance:Less than 1km(Maximal Unit: 32) Cable: Shielded Twisted Pair Cable(CPEV-S0.9φ) Terminator:Inside(Ter.Terminating Resistance Turnon with short circuit) Outline Dimensional Drawing Connector Pinouts Installation Power Consumption Power Voltage Measurement: Less than 0.3VA( Each Phase) Input Current Measurement: Less than 0.1VA(Each Phase) Power: Less than 10.0VA Output Auxiliary Power:85∼ 264V AC /85∼ 150V DC 20∼30V DC Conservation Temperature:-20∼70℃ Operating Temperature: -10∼50℃ Operating Humidity:30∼85%RH(Non Condensing) ◆Power Terminal Dimension:W110×H110×D126 mm Aux. Power Mass:Approx. 500g Others: ・Never install in places which are subject to direct sunlight. ・Never install in places which are subject to dust. ◆Input Terminal DC Input×3 Performance Input Input Input Tolerance Item Current DC Voltage DC Watt DC Current AC Voltage AC Tolerance ±1.0% ±1.0% ±1.5% ±1.0% ±1.0% 3 DC Input 2 DC Input 1 DC Input Permissible Limit:Accuracy of Reading Item Ampere-hour Watt-hour Load Current (% of rating) 5∼ 100 5∼ 100 Accuracy ±2.0% ±2.0% Response Time(Within ±1% of the last value):Less than 4 sec Display Update Time : 0.5 sec Insulation Resistance : Between Input− Output− Aux. power− earth, Over 100MΩ/500V DC DC Input×2, AC Input×1 Input Input AC Current Input (AC Voltage Input) RM112 DC Input×1, AC Input×2 Input AC A Input (AC A Input AC A Input AC V Input) (AC V Input (AC V Input AC A Input) AC V Input) ◆Output Terminal ●No Output Power Display Switch Input ●RS-485 Terminator Power Display Switch Input Communication Output ●3 Analog Output Analog Output Analog Output Analog Output Shunt, Multiplier Rating Rated value not written in the table cannot be setup. Rated Shunt Current 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 80A 100A 120A 150A 200A 250A 300A 400A 500A 600A 750A 800A 1000A 1200A 1500A 2000A 2500A 3000A Rated Multiplier V 450V 500V 600V 700V 750V 1k V 1.5k V 2k V 105k V