Figure 1: Saturation Properties at 1atm FC-87 FC-72 FC-84 FC-77 FC-43 Property FC-40 Boiling point [C] f [kg/m3] v [kg/m3] [kg/ms] cp [J/kg-K] hfg [J/kg] K [W/m-K] [N/m] [1/K] Dielectric Constant Molelular Weight [kg/kmole] CHF [W/cm2] 100 83 56 30 156.6 1590 1575 1592 1633 1870 13.28 14.31 12.68 11.58 25 2.47E-3 4.20E-4 4.5E-4 4.2E-4 4.5E-4 1172 1130 1088 1088 1252.8 79553 83740 87927 87927 71162 6.38E-2 5.51E-2 5.45E-2 5.35E-2 5.7E-2 8E-3 16E-3 8.90E-3 8.5E-3 7.7E-3 1.12E-3 1.5E-3 1.5E-3 1.4E-3 1.2E-3 1.75 1.71 1.72 1.71 1.83 438 388 338 288 650 13.53 15.00 14.86 14.76 21.9 R-113 Water 100 48 172 958 1511 1545 0.59 7.4 18.35 2.7E-4 3.9E-4 5.03E-4 4184 979 1255 71179 146824 2257044 6.5E-2 7.02E-2 6.83E-1 4.5E-3 1.47E-2 5.89E-2 2E-4 0.75E-3 1.7E-3 78 2.4 1.68 18 187 670 135.7 23 11.66 Figure 2: Liquid Module Design Open to Air Water-Cooled Condenser Cooling Water Brass Rod Electrodes/Supports Cooling Water Acrylic “Box” Semi-Flexible Hose Liquid Thermocouple Platinum Wire Figure 3: Experimental System lamp condenser cooling water Vs shunt resistor Vwire main power supply thermocouple ice reference Vtc camera