Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Control technique Interface relay MK 3044 Output interface relay 0232909 · · · · · · Approvals and marking Principle circuit diagram A1 11 21 12 14 22 24 B1 B2 According to IEC 255, VDE 0435 part 201 With separate control input very low control current £ 5 mA With changeover contacts for switching of low and big loads With LED indicator Width 22,5 mm Application I 5mA A2 M6168_b · Link between control and power levels · For separating potentials Some electronic devices, e.g. frequency inverters, microprocessor systems etc. offer the possibility to signalize faults and operating conditions via one or more logic outputs. However, the problem is the minimum loading of these outputs and the voltage of e.g. DC 15 V, which is not normal in the control technique. Circuit diagram Function A1 11 21 The MK 3044 is a interface relay with an additional control input. The supply voltage DC 24 V will be applied to A1/A2. The relay switches, when the input B1/B2 is connected to a voltage between AC/DC10...30 V. B1 B2 L1 L2 11 21 Indication LED: T1 T2 12 14 on, when relay energised 22 24 Technical data 22 24 M5733 Input 12 14 A2 MK 3044.12 Nominal voltage A1-A2: Control voltage B1-B2: Voltage range: Control current B1-B2: Nominal consumption: DC 24 V AC/DC 10 ... 30 V 0,9 ... 1,2 UN £ 5 mA £1W Output Contacts MK 3044.12: Switching voltage: Switching current: Turn-off time: Thermal current I th: Switching capacity to AC 15 NO contact: NC contact: Electrical life to AC 15 at 3 A, AC 230 V: Permissible switching frequency: Short circuit strength max. fuse rating: Mechanical life: All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 2 changeover contacts U = 0,3 ... 60 V I = 1 ... 300 mA 7 ms 5A 3 A / AC 230 V 1 A / AC 230 V EN 60 947-5-1 EN 60 947-5-1 EN 60 947-5-1 > 3 x 105 switching cycles 3000 switching cycles / h 6 A gL EN 60 947-5-1 > 30 x 106 switching cycles MK 3044 / 09.11.01 d Technical data General data Operating mode: Temperature range: Clearance and creepage distances overvoltage category / contamination level: EMC Electrostatic discharge: HF-irradiation: Fast transients: Surge voltages between wires for power supply: between wire and ground: Interference suppression: Degree of protection: Housing: Terminals: Housing: Vibration resistance: Climate resistance: Terminal designation: Wire connection: Wire fixing: Mounting: Weigth: Continuous operation - 20 ... + 60 °C 4 kV / 2 IEC 60 664-1 8 kV (air) 10 V/m 2 kV EN 61 000-4-2 EN 61 000-4-3 EN 61 000-4-4 1 kV 2 kV Limit value class B EN 61 000-4-5 EN 61 000-4-5 EN 55 011 IP 40 EN 60 529 IP 20 EN 60 529 Thermoplastic with V0 behaviour according to UL subject 94 Amplitude 0,35 mm frequency 10 ... 55 Hz EN 60 068-2-6 20 / 60 / 04 EN 60 068-1 EN 50 005 2 x 1,5 mm 2 solid or 2 x 1,0 mm2 stranded wire with sleeve DIN 46 288-1/-2/-3/-4 Flat terminals with self-lifting clamping piece EN 60 999 DIN rail EN 50 022 140 g Dimensions Width x height x depth: 22,5 x 82 x 99 mm Standard type MK 3044.12 DC 24 V Article number: · Output: · Nominal voltage UN: · Width: 0036733 2 changeover contacts DC 24 V 22,5 mm stock item Ordering example MK 3044 .12 DC 24 V Nominal voltage Contacts Type E. DOLD & SÖHNE KG • D-78114 Furtwangen e-mail [email protected] • internet http://www.dold.com • Postf. 1251 • Tel. +49 7723 654 0 • Telefax +49 7723 654 356 2