* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SW1/SW2 - Mega El
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical ballast wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Control system wikipedia , lookup
Power inverter wikipedia , lookup
Current source wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Oscilloscope history wikipedia , lookup
Surge protector wikipedia , lookup
Distribution management system wikipedia , lookup
Alternating current wikipedia , lookup
Crossbar switch wikipedia , lookup
Integrating ADC wikipedia , lookup
Stray voltage wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Voltage regulator wikipedia , lookup
Power electronics wikipedia , lookup
Protective relay wikipedia , lookup
Mains electricity wikipedia , lookup
Schmitt trigger wikipedia , lookup
Buck converter wikipedia , lookup
trigger relay in 11.25mm housing SW1/SW2 overview power supply 24V~= 1 SPCO output max. 10A trigger input with 1/0/Auto switch SW1 SW2 3,0V ON 7,0V ON 2,5V OFF 6,5V OFF LED indicators for output 1 11.25mm DIN rail mount housing IN SW1/SW2: The SW1 and SW2 trigger is designed to control pumps, fans, burners etc. DIN The SW1/SW2 trigger is also designed to operate with an analogue 0-10VDCcontrol signal. As soon as the input voltage reaches the operating threshold, in AUTO Mode, the relay is activated. If the input voltage falls below the cutout threshold, the relay cuts out again. A manual control facility with feedback function (mode 1) is incorporated for servicing purposes. The module can be operated in two modes which can be selected by the three-position switch(Auto, 0, 1). The output relay is controlled via terminals A1, A2 1. Switch position “1”: 2. Switch position “Auto”: The output relay is controlled by a trigger, through terminals YR. The operating voltage must be available continuously at terminal A1. 3. Switch position “0”: The relay is switched off. Input signals at terminals A1 or YR are ineffective. A1 12 14 +YR 3V(7V) B1 coil voltage duty cycle nominal current suppressor circuit relay type output relay spec 230V~ Ie AC-15* 120V~ Ie AC-15* 240V~ Ie DC-13* 24V= on delay off delay contact material 11 2.5V(6.5V) (bei SW2) B2 specification 1 0 A switching voltage input current continuous current min. switching capacity max. switching frequency mechanical electrical operating conditions 11 YR B1 A1 Supply = U = A1-A2 A1 A2 B1 YR > > -A2 + ~ nominal voltage +10% / -15% 100% 15mA freewheeling diode and varistor 1 10A 5A 4A 4A <8ms <25ms AgCdO 250V~ 16A 10A 5mA 600/h 2 x 106 5 1 x 10 7 1 x 10 5 1 x 10 -20 to +60 °C non condensing 1 * EN 60947-5-1 VDE 0435 0 14 11 part no 4:04 ~- 14 12 A2 12 B2 B2 A ordering information output relay type housing types SW1 24Vac/dc 24V~= supply 600mW SPCO 1 O Sw2 24Vac/dc 24V~= 600mW SPCO 1 O S01.00 HIQUEL 2004 HIGH QUALITY ELECTRONICS