* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 1./ RANGE OF APPLICATIONS: 2./ BUILD, INSTALLATION and
Nanogenerator wikipedia , lookup
Power MOSFET wikipedia , lookup
Charge-coupled device wikipedia , lookup
Index of electronics articles wikipedia , lookup
Automatic test equipment wikipedia , lookup
Opto-isolator wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Optimum HDTV viewing distance wikipedia , lookup
Surge protector wikipedia , lookup
Crossbar switch wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
CK24 CAPACITIVE PROXIMITY SWITCH 1./ RANGE OF APPLICATIONS: A capacitive proximity switch may primarily be used for level controlling of tanks or noncontact sensing of various materials. They are, for example: granulated, fluid, powdered or solid; as for their material: metal and non metal: plastic, glass, wood, water, organic, dry feed, processed materials, etc. The proximity switch can differentiate between liquids based on their pollution or quality. (It will be suitable for separating oil, water or oily water, for instance → see waterworks, power plant, etc.) The switching distance (where the device switches on) depends on the material because the dielectric constants are different. A helical potenciometer is placed on the back side of the device, which may be used to set this switching distance. The most common materials' distance dependence are shown below. 2./ BUILD, INSTALLATION and SETTING OF THE DEVICE: The electronic control unit of the device is placed in a nickel-plated brass threaded housing, sealed with a plastic cap and a connecting cable. Because of the IP65 protection, the electronic control unit has been moulded with twocomponent synthetic resin. The setting of the switching distance and the mounting of the device are done with two mounting nuts. The device should be set as close to the material as possible, then the exact distance is to be set with the potenciometer on the back side of the device. An arrow (-+) on the data label shows how the switching distance is growing and diminishing when turning the potentiometer ATTENTION! The temperature coefficient of the device deteriorates greatly when a switching distance of over 10 mm (CK24-10) or 20 mm (CK24-20) is set. We recommend you only apply these settings (over 10 or 20 mm) at permanent temperature. (Sensibility with earthed metal plate). 3./ MOUNTING: In order to avoid the mutual effects of disturbances the mechanical instructions must be kept when setting. (In the case of the non-flush mountable model, the distance must be kept even with one device.) 4./ TECHNICAL PARAMETERS: Main voltage : 10-30 V DC No-Load current : max. 20 mA Switching distance may be set: - Type CK24-20 : 5-30 mm - Type CK24-10 : 3-20 mm Switching hysteresis: : 3-5 % Load current : <200 mA Switching frequency : 40-150 Hz (depend on switching distance) Ambient operating temperature : - 10…+ 55 °C Mechanical protection : IP65 Protection: - Polarity reversal - Output short circuit protection - Inductive voltage peaks Output: PNP, closing (NPN, or opening models may be ordered) 2 Cable [(PUR)/3x0,34 mm / 2,5 m,] KONTAKT-Elektro Kft. H-7630 Pécs, Mohácsi út 79. tel.: +36 (72) 324-038 fax.: +36 (72) 516-069 E-MAIL: [email protected] http://www.kontakt-elektro.hu