Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Product Information PI “ SD Series I.I.” Toshiba X-ray Image Intensifier E5863SD-P4 Input Field : 150 mm (6″ ) Output Image Diameter: 20 mm FEATURING: High Resolution High Conversion Factor High contrast ratio “ SD Series I.I.” E5863SD-P4 is used for medical radiographic diagnosis. This X-ray Image Intensifier is intended to be connected with IEC ClassⅠequipment. “ SD Series I.I.” E5863SD-P4 has been perfected by the integration of several aspects of advanced technology; The input window is of a thin metal plate, which has good X-ray transparency characteristics and reduces X-ray scatter. It uses a thick input phosphor screen made with an extremely fine pillar shaped structure. This has high X-ray absorption and very high conversion efficiency. In addition, there is a thin output phosphor screen on a single thick-glass output window with an anti-reflective coating, offering very high contrast for small details, very low structure noise and high MTF characteristics. The E5863SD-P4, employing these manufacturing techniques, provides outstanding performance in resolution, brightness, contrast and noise. ★The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA ELECTRON TUBES & DEVICES CO., LTD. (TETD) for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TETD or others. ★The information contained herein may be changed without prior notice. It is therefore advisable to contact TETD before proceeding with the design of equipment incorporating this product. E5863SD-P4 PERFORMANCE DATA Specification Central Resolution Conversion Factor (Gx) Contrast Ratio 10 % area 10 mm dia. DQE (IEC standard) 54 Lp/cm typ. 18 (cd/m2)/ (μ Gy/s) typ. 160 (cd/m2)/ (mR/s) typ. 30:1 typ. 20:1 typ. 65 % typ. GENERAL DATA MECHANICAL Specification Overall Length Maximum Diameter Nominal Entrance Field Size Useful Entrance Field Size Output Image Diameter Weight (approx.) Dimensional Outlines 276±5 mm 206±2 mm 150 mm min. 140 mm min. 20±0.5 mm 13 kg Refer to page 5 POWER SUPPLY Specification DC Power Supply Input Voltage Output Voltage High Voltage Power Supply (Built-in) Input Voltage ENVIRONMENTAL Specification Temperature Humidity Pressure AC100 to 240Vac 24±1Vdc 24±1 Vdc Under delivery and stock -15 to 45 ℃ 10 to 90 % 50 to 106 kPa -2- Under operating 5 to 40 ℃ 30 to 85 % 70 to 106 kPa E5863SD-P4 ABSOLUTE MAXIMUM RATINGS Specification Anode Voltage G3 Electrode Voltage Potential Difference between Anode and G3 Electrode Potential Difference between G3 Electrode and G2 Electrode G2 Electrode Voltage G1 Electrode Voltage Photocathode Current Continuous Pulsed Input X-ray Dose 32 kV 5 kV 30 kV 5 kV 700 V 300 V 0.1 µA 2 µA 8.73×10-3Gy/min [1R/min] -3- E5863SD-P4 ELECTRICAL WIRING AND CONNECTING X-ray image intensifier is operated with 100 to 240Vac input voltage applied to the DC power supply. Wiring and connecting are shown as follows. ①: I.I. input cable ②: AC input cable ③: GND cable -4- E5863SD-P4 DIMENSIONAL OUTLINE Unit: mm -5- E5863SD-P4 OVERSEAS SUBSIDIARIES AND AFFILIATES For Sales & Technical Services, please contact the following representative: ・TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296 107 FAX +49 (211) 5296 402 ・TOSHIBA AMERICA ELECTRONIC COMPONENTS, INC. 2150 EAST LAKE COOK ROAD, SUITE 310 BUFFALO GROVE, ILLINOIS 60089 U.S.A PHONE +1 (847) 484-2400 FAX +1 (847) 541-7287 ・TOSHIBA ELECTRON DEVICES & MATERIALS (SHANGHAI) CO., LTD. (TEMS) RM1606, SH-PLAZA, No.336, XIZANG ROAD (MIDDLE), SHANGHAI, 200001, CHINA PHONE +86 (21) 6361-0077 FAX +86 (21) 6351-5760 (Product Development Engineering Dept.) 1385 SHIMOISHIGAMI, OTAWARA-SHI, TOCHIGI-KEN, 324-8550, JAPAN PHONE: +81-287-26-6666 FAX: +81-287-26-6060 http://www.toshiba-tetd.co.jp/ ● Toshiba Electron Tubes & Devices Co., Ltd. meets the Environmental Management System Standard, SO14001 ● Toshiba Electron Tubes & Devices Co., Ltd. meets internationally recognized Standards for Quality Management System ISO9001, ISO13485. PE-E5863SD-P4 2013